Venous Versus Arterial Blood Gas Sampling in Undifferentiated Emergency Patients
NCT04409470 · Status: COMPLETED · Type: OBSERVATIONAL · Enrollment: 250
Last updated 2022-06-16
Summary
In the emergency department and intensive care unit, blood gas analysis is a crucial tool in the assessment of critically ill patients. Blood gas analysis is quick and repeatable at the bedside. The sampling can be done from both arterial and venous samples, with arterial samples generally considered to be more reliable and by that widely used as the standard method.
The purpose of this project is to compare venous and arterial blood gas parameters in undifferentiated, critically ill patients. We plan to evaluate the correlation between different parameters through a prospective observational study. In particular, carbon dioxide partial pressure (pCO2) correlation between venous and arterial samples is investigated by using and comparing different conversion models proposed in the literature.
250 patients deemed to be in need of arterial blood gas sampling based on their clinical condition will be included in a consecutive fashion at all hours.
The long-term goal is to clinically translate the findings into a limitation on the use of arterial sampling, which could potentially reduce pain and complication risks in the many patients who undergo arterial blood gas sampling every day.
Conditions
- Dyspnea
- Hypercapnia
Interventions
- DIAGNOSTIC_TEST
-
Blood gas sampling from artery and vein
Patients included in this study are treated according to clinical routine. After inclusion, sampling of an arterial blood gas and a venous blood gas is performed simultaneously or as close in time as possible. Because the venous blood gas analysis sample can be taken directly from the patient's peripheral venous catheter, no additional venous puncture is usually required and the additional amount of blood that may be required is approx. 1 ml (the assay requires about 500 µl). In the very rare cases where it is not possible to establish a peripheral venous catheter within a reasonable time, the sample will be acquired from a new venous puncture together with other venous routine samples.
Sponsors & Collaborators
-
University Hospital, Linkoeping
lead OTHER
Principal Investigators
-
Matthias Jörg, MD · Emergency Department, University Hospital Linköping, Sweden
Eligibility
- Min Age
- 18 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2021-10-11
- Primary Completion
- 2022-03-27
- Completion
- 2022-03-27
Countries
- Sweden
Study Locations
More Related Trials
-
Hemodynamic Monitoring With Mixed Venous Saturation
NCT00303043 ·Status: COMPLETED
-
Evaluate the Relevance of the Use of Peripheral Venous Blood Gases for the Care of Patients in the S.A.U.V (Vital Emergency Rooms) of the CHU de Caen
NCT05971615 ·Status: COMPLETED ·Phase: NA
-
Capillary and Venous Lactate in Emergency Department Patients
NCT02694887 ·Status: COMPLETED
-
Correlation Between External Jugular Venous and Superior Vena Cava Central Venous Blood Oxygen Saturation in Patient Under General Anesthesia
NCT04017182 ·Status: UNKNOWN
-
Screening for Deep Vein Thrombosis in Intensive Care
NCT06246604 ·Status: RECRUITING ·Phase: NA
-
Correlation Between Peripheral and Central Venous Blood Partial Pressure of Carbon Dioxide in Critical Ill Patients
NCT03269448 ·Status: COMPLETED
-
Comparison of Traditional and Ultrasound-Guided Techniques for Vascular Access in Patients With Difficult Venous Access in Emergency Department.
NCT07013994 ·Status: COMPLETED ·Phase: NA
-
Systematic Screening for Deep Vein Thrombosis in Critically Ill Patients
NCT05019092 ·Status: UNKNOWN ·Phase: NA
-
Prediction of Arterial Lactate and Blood Gas Values Through the Analysis of Central Venous Blood
NCT04538339 ·Status: COMPLETED
-
Closed-blood Sampling Devices in the Adult Critically Ill Patient
NCT06478160 ·Status: RECRUITING ·Phase: NA
-
Hemodynamic Assessment of the Right Ventricle Using Pressure-volume Loop Catheter and Pulmonary Artery Catheter in Patients Undergoing Left Ventricular Assist Device Placement
NCT04478890 ·Status: COMPLETED
-
Effect of Emergency Department Bedside Compression Ultrasonography on Door-to-Disposition Time in Patients Suspicious for Lower Extremity Deep Venous Thrombosis
NCT05682040 ·Status: COMPLETED ·Phase: NA
-
Venous Site for Central Catheterization
NCT01479153 ·Status: COMPLETED ·Phase: NA
-
Daily Ultrasound-screening for CVC-related Thrombosis
NCT03327376 ·Status: COMPLETED
-
Antegrade Versus Retrograde IV for Blood Draws
NCT03533777 ·Status: COMPLETED ·Phase: NA
-
Blood Sampling Functionality of Extended Dwell Catheters
NCT04409418 ·Status: COMPLETED ·Phase: NA
-
Reliability of Ultrasound Examination of the Inferior Caval Vein
NCT04488627 ·Status: UNKNOWN
-
Critical Limb Ischemia and Transcutaneous Oximetry
NCT04369781 ·Status: UNKNOWN
-
Catheter Associated Asymptomatic Thrombosis in Intensive Care Unit
NCT04503135 ·Status: COMPLETED
-
IVC Ultrasound Versus Central Venous Pressure for Early Detection of Hypovolemia in Shock Patients
NCT07206732 ·Status: NOT_YET_RECRUITING
-
Comparison of Continuous Non-invasive Pressure Device Versus Invasive Pressure Measurement During Prehospital Emergency
NCT01627470 ·Status: UNKNOWN
-
Nurse-led Placement of Peripheral Venous Catheters in Overweight Patients Using Standard or Dynamic Ultrasound-guided Technique
NCT04412967 ·Status: COMPLETED ·Phase: NA
-
Ultrasound-guided Peripheral IV vs. Standard Technique in Difficult Vascular Access Patients by ICU Nurses
NCT03745209 ·Status: UNKNOWN ·Phase: NA
-
Central Venous Pressure Versus Inferior Vena Cava Distensibility Index in Assessing Fluid Responsiveness in Septic Shocked Patients
NCT07279064 ·Status: NOT_YET_RECRUITING
-
Ultrasound Guided Versus Landmark Guided Arterial Line Placement by Emergency Medicine Interns
NCT03326739 ·Status: COMPLETED ·Phase: NA