Rotational Stability of the Acrysof, Tecnis and Envista Intraocular Lenses
NCT04345380 · Status: COMPLETED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 199
Last updated 2020-04-14
Summary
Brief Summary:
Age-related cataract is the main cause of impaired vision in the elderly population worldwide. In the UK, more than half of people who are over 65 years old have some cataract development in one or both eyes. The only treatment that can restore functional visual ability is cataract surgery where the opacified crystalline lens is removed by phacoemulsification and an artificial intraocular lens is implanted. It is estimated that around 10 million cataract operations are performed around the world each year. Cataract operations are generally very successful, with a low risk of serious complications.
During the past two decades, cataract surgery underwent tremendous change and modernisation resulting in today's small incision phacoemulsification surgery and a safe technique with a short rehabilitation time for the patient. Traditional spherical monofocal intraocular lenses (IOLs) restore best-corrected vision and may lessen the need for spectacles. These IOLs correct only the spherical portion of the total refractive error and do not correct corneal astigmatism. Astigmatism is a visually disabling refractive error affecting the general population, especially those with cataract. At least 15% to 20% of cataract patients have 1.5 diopters (D) or more of corneal or refractive astigmatism. With increased patient expectations, the trend is not only to remove the cataract but also to address the problem of pre-existing astigmatism at the time of surgery.
Surgical-induced astigmatism can be reduced by smaller incisions, i.e. microincision cataract surgery (MICS), which by definition is surgery performed through incisions smaller than 2.0 mm, reducing the need for suturing. This results in better corneal optical quality, thus improving visual outcomes. There are also other surgical options to correct preexisting astigmatism during cataract surgery like: selectively positioning of the phacoemulsification incision; astigmatic keratotomy with corneal or limbal relaxing incisions; excimer laser refractive procedures such as photorefractive keratectomy, laser in situ keratomileusis, and laser-assisted subepithelial keratectomy; or implanting pseudophakic toric posterior chamber intraocular lenses (IOLs).
Toric IOLs have been shown to result in good visual and refractive outcomes. Combined with MICS, these IOLs can allow effective correction of cylindrical errors intraoperatively, improving visual quality and thus leading to spectacle independence. Plate haptic and loop haptic toric IOLs have been considered for about a decade but have been associated with postoperative rotational instability. Rotation of a toric lens from its intended orientation degrades its corrective power, with approximately 3.3% loss of cylindrical power for every degree off axis. A misorientation of approximately 30° negates the effectiveness of astigmatic correction, and a misorientation of more than 30° may induce additional astigmatism. Although some patients are asymptomatic despite induced astigmatism, others experience symptoms such as blurred or distorted vision, headache, fatigue, eyestrain, squinting, or eye discomfort. Thus, IOL orientation stability is an essential goal in toric IOL design.
RATIONALE
The purpose of this study is to assess and compare the axial IOL rotation and optical quality (refraction, visual acuity, decentration and tilt) and capsular bag reaction after micro-incision surgery with an IOL implantation in cataract patients - Acrysof SN60WF, Tecnis ZCB00 \& Envista MX60 IOL
Conditions
- Cataract
- Astigmatism
Interventions
- OTHER
-
Implantation of an Alcon Acrysof SN60WF intraocular lens
Patients suffering from senile cataract getting replaced their human crystalline cataractous lens
- OTHER
-
Implantation of an AMO Tecnis ZCB00 intraocular lens
Patients suffering from senile cataract getting replaced their human crystalline cataractous lens
- OTHER
-
Implantation of an Envista MX60 intraocular lens
Patients suffering from senile cataract getting replaced their human crystalline cataractous lens
Sponsors & Collaborators
-
Medical University of Vienna
lead OTHER
Study Design
- Allocation
- RANDOMIZED
- Purpose
- TREATMENT
- Masking
- NONE
- Model
- SINGLE_GROUP
Eligibility
- Min Age
- 40 Years
- Max Age
- 90 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2015-06-09
- Primary Completion
- 2017-08-18
- Completion
- 2017-08-18
Countries
- Austria
Study Locations
More Related Trials
-
Assessment of Visual and Refractive Results and Rotational Stability of the TECNIS® Eyhance Toric II 1-piece Posterior Chamber Lens in Patients With Astigmatism Undergoing Cataract Surgery
NCT05144308 ·Status: TERMINATED ·Phase: NA
-
Evaluation of the Rotational Stability of The AcrySof Toric Intraocular Lens in the Capsular Bag in High Myopic Subjects
NCT01351233 ·Status: COMPLETED ·Phase: NA
-
Rotational Stability of Acrysof IQ Vivity Extended Vision Toric IOL and Refractive Visual Outcome.
NCT05119127 ·Status: COMPLETED ·Phase: NA
-
Evaluation of Long-term Safety and Performance of PanOptix Trifocal Intraocular Lens (IOL)
NCT06166901 ·Status: COMPLETED ·Phase: NA
-
Comparison of Toric IOL Implantation and Opposite Clear Corneal Incision During Cataract Surgery to Correct Corneal Astigmatism
NCT01763151 ·Status: COMPLETED ·Phase: PHASE4
-
Visual Performance With a Hydrophobic Aspheric Monofocal IOL
NCT03819582 ·Status: UNKNOWN ·Phase: PHASE4
-
Comparison of the Effect of Capsular Bend on the Rotational Stability Between Two Toric Intraocular Lenses
NCT06707740 ·Status: ACTIVE_NOT_RECRUITING
-
AMO's Tecnis™ Multifocal Intraocular Lenses (Tecnis MF), Alcon's ReStor Multifocal IOL
NCT01278420 ·Status: UNKNOWN ·Phase: PHASE4
-
Prospective Evaluation of the Tecnis Symfony Intraocular Lens (IOL)
NCT03579368 ·Status: UNKNOWN ·Phase: NA
-
Stability of Secondary Intraocular Lenses With no Capsular Support
NCT06345846 ·Status: ENROLLING_BY_INVITATION ·Phase: NA
-
Rotational Stability and Clinical Response of the ASQELIO Toric Biaspheric Monofocal Lens.
NCT06101472 ·Status: RECRUITING
-
Rotational Stability of the AcrySof® Toric
NCT00762216 ·Status: COMPLETED ·Phase: NA
-
Visual Function After Implantation of Bilateral AcrySof® Toric Natural Intraocular Lens
NCT00760487 ·Status: COMPLETED ·Phase: PHASE4
-
Visual Outcome and Visual Quality After Bilateral Implantation of the AcrySof® IQ IOL Compared to MI60® and Tecnis® IOL
NCT00760058 ·Status: WITHDRAWN ·Phase: PHASE4
-
Limbal Relaxing Incision Versus Toric Intraocular Lens for Corneal Astigmatism During Cataract Surgery.
NCT02067429 ·Status: UNKNOWN ·Phase: NA
-
Evaluation of the Tecnis™ Multifocal and Crystalens™ Accommodating Intraocular Lenses
NCT01061281 ·Status: COMPLETED ·Phase: PHASE4
-
Hydrophobic Acrylic Toric IOL Designed to Reduce the Effects of Preoperative Corneal Astigmatism
NCT01852084 ·Status: COMPLETED ·Phase: NA
-
Assessment of Visual Function and Optics in Intraocular Lenses
NCT01654159 ·Status: ENROLLING_BY_INVITATION ·Phase: NA
-
Comparison of the Effect of Hydrophobic Acrylic and Silicone 3-piece IOLs on Posterior Capsule Opacification
NCT01936701 ·Status: COMPLETED ·Phase: NA
-
Evaluation of the Rotational Stability of the Tecnis Toric II IOL
NCT04327518 ·Status: COMPLETED ·Phase: NA
-
The Incidence of Glistenings in the 2017 Intraocular Lenses Made by Alcon and Abbott Medical Optics
NCT03409185 ·Status: TERMINATED ·Phase: NA
-
Visual Quality and Performance of Eyes With Asqelio™ EDoF Toric Lenses
NCT06707545 ·Status: COMPLETED
-
Observation of Rotation of an Intraocular Lens
NCT02208232 ·Status: COMPLETED
-
Intraindividual Comparison of EMO IOLs
NCT05822089 ·Status: RECRUITING ·Phase: NA
-
Rayner Toric IOL Rotational Stability
NCT02393313 ·Status: UNKNOWN ·Phase: NA