Effect of CPAP on 6-Minute Walk Test Outcomes in Patients With ECAC
NCT04217603 · Status: RECRUITING · Phase: NA · Type: INTERVENTIONAL · Enrollment: 32
Last updated 2026-04-13
Summary
The purpose of this protocol is to perform a prospective, randomized, double-blinded, pacebo-controlled clinical trial to determine the influence of a non-invasive positive pressure ventilation device on exercise capacity and symptoms in adult patients with ECAC. Primary outcome will include the total distance traversed by the study subject during a standard 6-minute walk test, and secondary outcomes will include peak flow measurement and symptom reporting before and after the exercise testing. The study will focus on the use of continuous positive airway pressure (CPAP) device. CPAP is FDA-approved for the treatment of various medical conditions, including obstructive sleep apnea and heart failure, but is not FDA-approved for the treatment of ECAC. The study will enroll 32 ambulatory study subjects with confirmed ECAC at the BIDMC, and each study subject will be monitored for up to 3 months.
Conditions
- Tracheobronchomalacia
- Excessive Dynamic Airway Collapse
Interventions
- DEVICE
-
Continuous positive airway pressure (CPAP) device
Use of a CPAP during a 6 minute walk test to maintain the airways open during the respiratory cycle
- DEVICE
-
Sham-continuous positive airway pressure (CPAP) device
An enlarged air leak incorporated into the exhalation valve will be positioned between the mask and the CPAP tubing, allowing airflow resistance of the exhalation port to be almost eliminated by increasing its area, thereby virtually cancelling positive pressure. Also an orifice restrictor in the CPAP circuit will be connected between the CPAP unit and the tubing in order to load the blower with the same airflow resistance as in true CPAP.
Sponsors & Collaborators
-
Beth Israel Deaconess Medical Center
lead OTHER
Study Design
- Allocation
- RANDOMIZED
- Purpose
- TREATMENT
- Masking
- TRIPLE
- Model
- PARALLEL
Eligibility
- Min Age
- 18 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2023-03-01
- Primary Completion
- 2026-09-29
- Completion
- 2026-09-29
- FDA Device
- Yes
Countries
- United States
Study Locations
More Related Trials
-
Intermittent Intrapulmonary Deflation and Dyspnea Following Exercise in People With Chronic Obstructive Pulmonary Disease
NCT06956742 ·Status: RECRUITING ·Phase: NA
-
Oxygen Portable Concentrator During Exercises in Patients With COPD
NCT00875719 ·Status: COMPLETED ·Phase: NA
-
Breathlessness During Exercise: Experience and Memory
NCT03458182 ·Status: COMPLETED ·Phase: NA
-
Airway Clearance for Prevention of Chronic Obstructive Pulmonary Disease (COPD) Exacerbation
NCT00181207 ·Status: COMPLETED ·Phase: PHASE4
-
Comparison of the Cardiopulmonary and Gaz-exchange Response Between the Six-minute Stepper Test and the Incremental Cardiopulmonary Exercise Testing in Patients With Chronicle Obstructive Pulmonary Disease
NCT04008615 ·Status: COMPLETED
-
Benefits of Lightweight Ambulatory Oxygen Systems for Individuals With Chronic Obstructive Pulmonary Disease
NCT00325754 ·Status: TERMINATED ·Phase: NA
-
Home Oscillatory Positive Expiratory Pressure - Aerobic Exercise Rehabilitation Study
NCT06970054 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Comparison of Two Positive Expiratory Pressure Devices in Stable COPD Patients
NCT02817529 ·Status: WITHDRAWN ·Phase: NA
-
Effect of Exercise Ventilatory Support Pressure on Endurance in Patients With Severe Chronic Obstructive Pulmonary Disease - AVE-BPCO
NCT07125989 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
High-Flow in Hypercapnic Stable COPD Patients
NCT04281316 ·Status: TERMINATED ·Phase: NA
-
Effects of Automated Oxygen Titration Alone or With High Flow Nasal Therapy on Dyspnea and Exercise Tolerance
NCT05267418 ·Status: TERMINATED ·Phase: NA
-
Effects of Exhalation Valve on the Lack of Air and Exercise Tolerance in Patients With COPD
NCT02566915 ·Status: UNKNOWN ·Phase: NA
-
Effect of High Frequency Chest Wall Oscillation Vests on Spirometry Measurements
NCT03534986 ·Status: COMPLETED ·Phase: NA
-
Continuous Versus Demand-Based Oxygen in Patients With Fibrotic Interstitial Lung Disease and Chronic Obstructive Pulmonary Disease
NCT06767904 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Intrinsic PEEP and Laryngeal Aperture in COPD
NCT02437630 ·Status: UNKNOWN
-
Pilot Study of Physiological Effect of High-Flow Nasal Cannula on Respiratory Pattern and Work of Breathing
NCT02514798 ·Status: COMPLETED ·Phase: NA
-
Inspiratory Muscle Training in Hypercapnic COPD
NCT00291460 ·Status: UNKNOWN ·Phase: PHASE4
-
Effects of Lumbar Transcutaneous Electrical Nerve Stimulation on Exercise Performance in Patients With Chronic Obstructive Pulmonary Disease
NCT03312322 ·Status: COMPLETED ·Phase: NA
-
Prospective Study Comparing Different Modalities of Oxygen Delivery During Assessment of Functional Exercise Capacity
NCT00484562 ·Status: COMPLETED ·Phase: NA
-
Evaluation of Oscillatory Positive Expiratory Pressure (oPEP) in Bronchiectasis and COPD
NCT02282202 ·Status: COMPLETED ·Phase: NA
-
Effect of HFCWO Vests on Spirometry Measurements
NCT03628456 ·Status: COMPLETED ·Phase: NA
-
Assessing Exercise Capacity After PulseHaler™ Treatment in GOLD II-IV COPD Patients
NCT04236076 ·Status: UNKNOWN ·Phase: NA
-
Effect of Ventilation-Feedback Training on Exercise Performance in COPD
NCT00037973 ·Status: COMPLETED ·Phase: PHASE2
-
Bronchodilators and Oxygen Kinetics With Exercise in Chronic Obstructive Pulmonary Disease (COPD) Patients
NCT00354354 ·Status: COMPLETED ·Phase: PHASE4
-
Physiotherapy With Positive Expiratory Pressure (PEP) Bottle in Patients With Bronchiectasis
NCT06820918 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA