Summary
The ICD-Reality study is a non-commercial, investigator-led, multicenter, prospective, randomized, controlled trial. We aim to determine the effect of CRT-D or CRT-P implantation in non-ischemic cardiomyopathy and heart failure patients.
The reason why we initiated this trial is the lack of evidence-based treatment for the significant number of these patients. In these patients, 5-year mortality remains as high as 20% despite recent therapeutic advances. Based on currently available evidence, because of a significant decrease in mortality due to modern pharmacotherapy, it is not certain which of these patients should receive a CRT-P and who should receive a CRT-D. No dedicated and adequately powered trial has addressed this important question.
We hypothesize that patients with symptomatic HF, LVEF ≤35%, without left ventricular mid-wall fibrosis on LGE-CMR, will not benefit from CRT-D implantation compared with CRT-P only implantation.
If our hypothesis is confirmed, this could provide evidence for the management of these patients with a significant impact on common daily praxis and health care expenditures.
We aim to enroll 600 patients in the trial. 924 patients are needed to be screened for these 600 patients to be randomized.
Patients with non-ischemic HF visiting an out-patient department and possibly eligible for the trial will have their pharmacotherapy optimized.
Patients with a significant amount of fibrosis will be excluded from the study and treated according to local practice with an emphasis on ICD implantation to prevent SCD.
After fulfilling all eligibility criteria, including maximally tolerated pharmacotherapy, subjects will be randomized by the physicians who enrolled them in a 1:1 ratio to receive CRT-D or CRT-P implantation.
All patients will be followed-up for at least 3 years after the implantation.
Conditions
- Cardiomyopathy, Dilated, 3B
Interventions
- DEVICE
-
CRT-D
After randomization, devices will be implanted as soon as possible (within 2 weeks). The ICD will be programmed with anti-tachycardia pacing and shock therapy as per common praxis.
- DEVICE
-
CRT-P
After randomization, devices will be implanted as soon as possible (within 2 weeks).
Sponsors & Collaborators
-
University Hospital Olomouc
lead OTHER
Principal Investigators
-
Milos Taborsky, MD, PhD · University Hospital Olomouc
Study Design
- Allocation
- RANDOMIZED
- Purpose
- TREATMENT
- Masking
- QUADRUPLE
- Model
- PARALLEL
Eligibility
- Min Age
- 18 Years
- Max Age
- 99 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2020-06-30
- Primary Completion
- 2026-01-31
- Completion
- 2026-01-31
Countries
- Czechia
Study Locations
More Related Trials
-
Cardiac Magnetic Resonance Guidance of Implantable Cardioverter Defibrillator Implantation in Non-ischemic Dilated Cardiomyopathy
NCT04558723 ·Status: RECRUITING ·Phase: NA
-
Prospective Study on Prognosis of Cardiac Resynchronized Therapy (CRT), Implantable Cardioverter Defibrillator (ICD) Implantation in Patients With Congestive Heart Failure (CHF)
NCT02139449 ·Status: UNKNOWN
-
Dynamic Thoracic Impedance as a Marker for Heart Failure Decompensation
NCT02134379 ·Status: COMPLETED
-
Cardiovascular Magnetic Resonance GUIDEd Insertion of Implantable Cardiac Defibrillator in Dilated CardioMyopathy
NCT03993730 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
INvestigation on Routine Follow-up in CONgestive HearT FAilure Patients With Remotely Monitored Implanted Cardioverter Defibrillators (ICD) SysTems
NCT01200381 ·Status: COMPLETED ·Phase: NA
-
Resynchronization/Defibrillation for Ambulatory Heart Failure Trial
NCT00251251 ·Status: COMPLETED ·Phase: NA
-
TReatment of Atrial Fibrillation With Dual dEfibrillator in Heart Failure Patients
NCT00345592 ·Status: COMPLETED ·Phase: PHASE4
-
Pressure Wire Guided Cardiac Resynchronisation Therapy
NCT01464502 ·Status: UNKNOWN ·Phase: PHASE2/PHASE3
-
Clinical Investigation of the Medtronic EnTrust™ Implantable Cardioverter Defibrillator (ICD), Model D153ATG
NCT00273195 ·Status: COMPLETED ·Phase: NA
-
Clinical Evaluation of Cardiac Resynchronization Therapy (CRT) Using the Ovatio CRT Implantable Cardioverter-defibrillator (ICD) System
NCT00528320 ·Status: APPROVED_FOR_MARKETING
-
Re-evaluation of Optimal Re-synchronisation Therapy in Patients With Chronic Heart Failure
NCT03494933 ·Status: TERMINATED ·Phase: NA
-
The Prevention of Myocardial Enlargement and Dilatation Post Myocardial Infarction Study
NCT00605631 ·Status: COMPLETED ·Phase: NA
-
Optimisation of Decision Making for Defibrillator Implantation in Hypertrophic Cardiomyopathy
NCT03846297 ·Status: RECRUITING
-
MAgnetic Resonance Imaging-guided implanTation of Cardioverter DEFibrillators
NCT06269692 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Left Bundle Branch Pacing on Outcomes and Ventricular Remodeling in Biventricular CRT Nonresponders
NCT05760924 ·Status: RECRUITING ·Phase: NA
-
TRIAGE-CRT Telemonitoring in Patients With CHF and Indication of CRT-D
NCT00395642 ·Status: COMPLETED ·Phase: PHASE4
-
A Critical Pathway for Implantable Cardioverter-Defibrillators in Patients With Ischemic Cardiomyopathy
NCT01248702 ·Status: UNKNOWN ·Phase: NA
-
Reduction of Inappropriate Implantable Cardioverter Defibrillator (ICD) Therapies in Primary Prevention Patients
NCT01217528 ·Status: COMPLETED ·Phase: NA
-
Study of the Implantable Cardioverter Defibrillator (ICD) Intracardiac Electrograms
NCT00916435 ·Status: COMPLETED
-
Efficacy of Implantable Cardioverter Defibrillator in Patients With Non-ischemic Systolic Heart Failure on Mortality
NCT00541268 ·Status: COMPLETED ·Phase: NA
-
Assessment of Ventricular Arrhythmia Risk After CRT-D Replacement for Patients With Primary Prevention Indication
NCT02323503 ·Status: COMPLETED
-
Treatment Satisfaction in Implantable Cardioverter Defibrillator Recipients
NCT01230073 ·Status: COMPLETED ·Phase: PHASE4
-
Ensure Cardiac Resynchronization Therapy Study
NCT00291564 ·Status: COMPLETED
-
Efficacy, Safety and Cost of Remote Monitoring of Patients With Cardiac Resynchronization Therapy
NCT03012490 ·Status: COMPLETED ·Phase: NA
-
Assessment of Pacing Stimulus Conduction and Latency Measurements in CRT-D Patients
NCT03314675 ·Status: TERMINATED ·Phase: NA