Pressure Wire Guided Cardiac Resynchronisation Therapy
NCT01464502 · Status: UNKNOWN · Phase: PHASE2/PHASE3 · Type: INTERVENTIONAL · Enrollment: 282
Last updated 2017-04-04
Summary
Heart failure patients may benefit from having a special pacemaker implanted that can make the heart pump in a more coordinated and efficient way Cardiac Resynchronisation Therapy (CRT). For the heart to pump well it is necessary for the pacing wires to be placed in optimal positions. Only two thirds of people respond to CRT and this may be because of non-ideal pacing wire position. A potential marker for response is the change in heart pump pressure change over time. The aim of this study is to use a specialised wire in the main pumping chamber of the heart to record the pressure changes with the pacing lead in various positions to determine the optimal position. It is postulated that the improved pressure changes will increase the proportion of responders.
Pilot study work has shown that the work is technically feasible and safe. The initial data has been published in a highly regarded scientific journal. This main study will be a multicentre randomised controlled trial whereby patients will be randomised to either standard treatment or pressure wireguided treatment. The patients in the pressurewire guided arm will have a specialised wire implanted into the main pumping chamber of their heart via a blood vessel at the top of the leg (or less commonly a blood vessel in the wrist). This will measure acute pressure changes over time and the pacing lead will be positioned in the site that gives the greatest change in pressure.
If the patients in the pressurewire guided arm fare better than those receiving standard treatment it may alter how a large proportion of heart failure patients are treated around the world. The study requires 282 patients and is likely to take two years to complete.
Conditions
Interventions
- PROCEDURE
-
Standard CRT Implant
- PROCEDURE
-
Pressure-wire guided CRT implant
A pressure wire will be sited in the left ventricle to measure dP/dT max. The LV lead position that gives the highest dP/dT max will be the final position used.
Sponsors & Collaborators
-
Abbott Medical Devices
collaborator INDUSTRY -
Guy's and St Thomas' NHS Foundation Trust
lead OTHER
Study Design
- Allocation
- RANDOMIZED
- Purpose
- TREATMENT
- Masking
- NONE
- Model
- PARALLEL
Eligibility
- Min Age
- 18 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2012-09-30
- Primary Completion
- 2018-04-30
- Completion
- 2018-04-30
Countries
- Italy
- United Kingdom
Study Locations
More Related Trials
-
CRT In Narrow QRS Heart Failure: Mechanistic Insights From Cardiac MRI And Electroanatomical Mapping
NCT03258060 ·Status: TERMINATED ·Phase: NA
-
Cardiac Resynchronization Therapy (CRT)-Narrow-dp/Dt-Study
NCT00821938 ·Status: COMPLETED ·Phase: PHASE4
-
Triple-site Biventricular Stimulation in the Optimization of CRT
NCT02350842 ·Status: COMPLETED ·Phase: NA
-
Selective Coronary Vein Sampling in Left Bundle Branch Block and CRT
NCT02396875 ·Status: UNKNOWN ·Phase: NA
-
Cardiac Resynchronization Therapy (CRT) Based Heart Failure Monitoring Study
NCT00632372 ·Status: COMPLETED
-
Optimal Left Ventricular Lead Positioning During Cardiac Resynchronisation Therapy; Comparison of Two Methods of Targeting
NCT03769272 ·Status: UNKNOWN
-
Advance Cardiac Resynchronization Therapy (CRT) Registry
NCT01805154 ·Status: COMPLETED
-
DANISH-CRT - Does Electric Targeted LV Lead Positioning Improve Outcome in Patients With Heart Failure and Prolonged QRS
NCT03280862 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Application of Right Atrial Left Ventricular Fusion Pacing in Patients With CRT Indications
NCT03071978 ·Status: COMPLETED ·Phase: NA
-
A Pilot Study of Interventricular Septal Puncture for Cardiac Resynchronization Therapy to Treat Heart Failure
NCT01818765 ·Status: COMPLETED ·Phase: NA
-
Electrical Optimization of Cardiac Resynchronization Therapy in Non-responder Patients
NCT03789487 ·Status: TERMINATED ·Phase: NA
-
Comparison of Right Ventricular Septal and Right Ventricular Apical Pacing in Patients Receiving a CRT-D Device
NCT00833352 ·Status: COMPLETED ·Phase: NA
-
A Comparison of Two Techniques for Choosing the Best Place to Put a Pacing Lead for Cardiac Resynchronisation Therapy
NCT02061241 ·Status: COMPLETED
-
PRISM Cardiac Resynchronisation Therapy (CRT) Randomised Controlled Trial
NCT01429753 ·Status: UNKNOWN ·Phase: PHASE2/PHASE3
-
Response to Cardiac Resynchronization Therapy of Previously Right Ventricular Paced Heart Failure Patients
NCT01466621 ·Status: COMPLETED
-
MultiPoint Pacing Programming Guided by Noninvasive Hemodynamics
NCT02064751 ·Status: COMPLETED ·Phase: NA
-
Cardiac Resynchronisation Study
NCT01213537 ·Status: COMPLETED
-
Programming Implantable Cardioverter Defibrillators in Patients With Primary Prevention Indication
NCT00743522 ·Status: COMPLETED
-
Metabolic Mapping and Cardiac Resynchronization
NCT03420833 ·Status: COMPLETED ·Phase: NA
-
CT Guided WiSE-CRT
NCT03495505 ·Status: COMPLETED ·Phase: NA
-
Image Guided Mapping for Cardiac Pacing Intervention
NCT01638754 ·Status: COMPLETED ·Phase: NA
-
Cardiac Resynchronization Therapy (CRT) Efficacy Study
NCT00822146 ·Status: COMPLETED ·Phase: NA
-
His-Bundle Corrective Pacing in Heart Failure
NCT05265520 ·Status: RECRUITING ·Phase: NA
-
Next Generation INCEPTA Implantable Cardioverter Defibrillator (ICD) and Cardiac Resynchronization Therapy (CRT-D) Field Following Study
NCT01227785 ·Status: COMPLETED
-
Multicenter Automatic Defibrillator Implantation Trial - Chemotherapy-Induced Cardiomyopathy
NCT02164721 ·Status: COMPLETED ·Phase: NA