Summary
Individuals with lower limb amputation often complain about uncomfortable residual limb skin temperatures and the accumulation of sweat inside their prostheses. It doesn't take long before the presence of sweat on the residual limb leads to a lack of confidence in the security of their prosthetic suspension. Some circumstances allow the wearer to doff the prosthesis before it falls off, wipe it and the residual limb dry, and then don it again. Another option is to simply reduce the intensity of activities before sweat becomes a problem. However, the Warfighter amputee may not be afforded such accommodations. For these service personnel, inadequate moisture management can significantly limit or inhibit their mobility. The objective of the proposed research is to provide lower limb amputees who work in demanding environments with a prosthesis that remains secure despite profuse residual limb sweating without compromising residual limb health and comfort.
The aim of this research is to compare three different, lower limb prosthetic suspension systems and identify which is most effective at maintaining a secure adherence when worn in conditions that result in profuse sweating. The investigators also aim to compare how the three study prostheses effect residual limb skin health and comfort when participants pursue their usual activities in the home, work, and community environments.
To achieve these aims, the investigators will to recruit 25 below-knee amputees. Each subject will be asked to be asked to wear: (1) their as-prescribed prosthesis, (2) a prosthesis with a perforated elastomeric liner that allows sweat to flow away from the skin, and (3) a prosthesis that has a battery and body-weight activated pump to flow air between the prosthesis and the residual limb skin, allowing expulsion of any accumulated sweat. Subjects will wear each of these prostheses in the home, work, and community environments for two weeks, after which the investigators will measure their residual limb health and comfort. Subjects will then walk on a treadmill in a room whose climate will be set to Middle East-like conditions: 35 °C (95 °F) and 50% relative humidity. After 30 minutes, the investigators will measure any slippage of their prosthesis relative to their limb and how much sweat is expelled. The investigators hypothesize there will be differences in the amount of slippage, residual limb health, and comfort between the three prostheses.
Conditions
- Lower Extremity Amputation
Interventions
- DEVICE
-
Dynamic Air Exchange - Rising Edge Design (DAE-RED)
The DAE-RED suspension system expels perspiration to the prosthesis exterior using a hybrid battery-powered pump and a body-weight activated pump. To use the DAE-RED, subjects will be fit with a modified patellar tendon-bearing socket that fits over a custom liner and sock. Up to four air intake ports are located proximally on the liner, approximately 25 mm superior to the socket brim. These ports incorporate a microvalve that allows air to flow into the liner-skin interstitial space while still maintaining a vacuum suspension. Distally, the pin lock has a 3-mm hole along its longitudinal axis that allows perspiration to be expelled into a distal reservoir. The prosthesis will also include: a standard aluminum pylon, pyramid adapters, and an Ossur Proflex XC prosthetic foot with Unity pump and foot cover.
- DEVICE
-
Perforated elastomeric liner
The unique element of this perforated elastomeric liner are small perforations (\~0.3 mm diameter), uniformly distributed on a 4 x 5 mm grid, but with no perforations on the distal umbrella, that allow perspiration to be exuded into the liner-socket interstitial space. To use the perforated elastomeric liner, subjects will be fit with a modified patellar tendon-bearing socket that fits over a sock and the perforated elastomeric liner with a pin lock. The sock, worn between the socket and the liner, is used to absorb perspiration that is transported through the perforations in the liner. When needed for residual limb volume control, additional socks will be donned and included in tare weighing. The prosthesis will also include: a standard aluminum pylon, pyramid adapters, and an Ossur Proflex XC prosthetic foot and cosmesis.
- DEVICE
-
As-prescribed prosthesis
The individual's as-prescribed suspension system is the prosthesis prescription that the patient and their clinical care team believes is the best prosthesis for their needs.
Sponsors & Collaborators
-
United States Department of Defense
collaborator FED -
Seattle Institute for Biomedical and Clinical Research
lead OTHER
Principal Investigators
-
Glenn K Klute, PhD · Dept. of Veterans Affairs
Study Design
- Allocation
- RANDOMIZED
- Purpose
- TREATMENT
- Masking
- NONE
- Model
- CROSSOVER
Eligibility
- Min Age
- 18 Years
- Max Age
- 70 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2019-02-17
- Primary Completion
- 2022-06-28
- Completion
- 2022-06-28
- FDA Device
- Yes
Countries
- United States
Study Locations
More Related Trials
-
An Automatically Adjusting Prosthetic Socket for People With Transtibial Amputation
NCT05124652 ·Status: RECRUITING ·Phase: NA
-
Influence of Prosthetic Foot Stiffness on Transtibial Osseointegrated Bone-Anchored Limb Outcomes
NCT07263945 ·Status: RECRUITING ·Phase: PHASE1
-
Deploying Digital Prosthetic Interface Technology and Exercise in Dysvascular Amputees
NCT05656924 ·Status: ACTIVE_NOT_RECRUITING ·Phase: PHASE2
-
Development of Adaptive Vacuum Suspension to Improve Prosthetic Fit and Residual Limb Health
NCT03927404 ·Status: COMPLETED ·Phase: NA
-
The Safety of Reusing Walking Boot Components for Patients Recovering From Acute Foot and Ankle Injuries
NCT07287969 ·Status: ENROLLING_BY_INVITATION ·Phase: NA
-
Bioimpedance as a Diagnostic Tool for Assessing the Need for Socket Modification in Transtibial Amputees
NCT03164356 ·Status: COMPLETED ·Phase: NA
-
Effects of Wearing a Powered Ankle-Foot Prosthesis on Amputee Walking
NCT00869947 ·Status: COMPLETED ·Phase: NA
-
Hyperhidrosis, Developing a Treatment Approach Aims 1 & 2
NCT03416348 ·Status: COMPLETED ·Phase: PHASE1
-
Early Protected Full Weight-bearing vs. Partial Weight-bearing After Surgical Fixation of Unstable Ankle Fractures, Monitored With Bio-feedback Insoles.
NCT06023979 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Biomechanical Assessment of Gait in Lower-Extremity-Amputees
NCT01332123 ·Status: COMPLETED ·Phase: NA
-
Automatic Prosthetic Foot Stiffness Modulation to Improve Balance
NCT06711588 ·Status: RECRUITING ·Phase: NA
-
Limb Health and Socket Pressure in Response to Powered Ankle Protheses
NCT05112679 ·Status: COMPLETED ·Phase: NA
-
Prosthetic Smart Socket Technology to Improve Patient Interaction, Usability, Comfort, Fit, and Function.
NCT03199222 ·Status: UNKNOWN ·Phase: NA
-
Comparing Active and Passive Ankle-foot Prostheses
NCT01684501 ·Status: COMPLETED
-
To Assess the Utility of the Point Partial in a Clinical Take-home Study of Partial Hand Amputees
NCT05012683 ·Status: COMPLETED ·Phase: NA
-
Evaluation of a Pro-Active Dynamic Accommodating Socket
NCT01546311 ·Status: UNKNOWN
-
Evaluation of a Novel Transfemoral Prosthetic Socket System
NCT01846845 ·Status: UNKNOWN ·Phase: NA
-
Biomechanical Evaluation of a Novel, Compliant Low Profile Prosthetic Foot
NCT06468059 ·Status: COMPLETED ·Phase: NA
-
Amputee Residual Limb Volume Fluctuation
NCT01161238 ·Status: COMPLETED
-
Evaluation of the Biomechanics of Crowding and the Energetic Cost of Endurance Runners Unilateral Transtibial Amputees.
NCT06948695 ·Status: RECRUITING ·Phase: NA
-
Comparative Performance of Dynamic Elastic Response Feet
NCT02542761 ·Status: COMPLETED ·Phase: NA
-
Improving Socket Fit in Female and Male Veterans With Transtibial and Transfemoral Amputation
NCT05989243 ·Status: RECRUITING
-
Transfemoral Powered Foot and Physical Therapy Study
NCT03625921 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Gait Parameters in a Cohort of Patients Fitted With a Canadian Prosthesis: Contribution of Quantified Gait Analysis
NCT06994741 ·Status: COMPLETED
-
Effect of Ankle Splinting on Vascular Function in Aging
NCT02144896 ·Status: COMPLETED ·Phase: NA