Comparison of Clinical Outcomes POD L GF vs POD F GF (PHY1707)
NCT03688399 · Status: COMPLETED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 53
Last updated 2022-01-11
Summary
Prospective, randomised, controlled, single-surgeon, single-center clinical study to compare the clinical outcomes of two trifocal IOLs differing in the dominance of additional power. The investigational device POD L GF shows dominance for the intermediate addition (+1.75 D), whereas the control device POD F GF shows dominance for the near addition (+3.5 D). Implantation of the IOLs is bilaterally.
Conditions
- Cataract
- Lens Opacity
- Presbyopia
Interventions
- DEVICE
-
IOL implantation experimental
Implantation of trifocal IOL POD F GF consisting of light distribution order: far \> intermediate \> near
- DEVICE
-
IOL implantation comparator
Implantation of trifocal IOL POD F GF consisting of light distribution order: far \> near \> intermediate
Sponsors & Collaborators
-
Beaver-Visitec International, Inc.
lead INDUSTRY
Principal Investigators
-
Zoltan Nagy, MD · Semmelweis University - Department of Ophthalmology
Study Design
- Allocation
- RANDOMIZED
- Purpose
- TREATMENT
- Masking
- NONE
- Model
- PARALLEL
Eligibility
- Min Age
- 40 Years
- Sex
- ALL
- Healthy Volunteers
- Yes
Timeline & Regulatory
- Start
- 2018-07-30
- Primary Completion
- 2021-02-01
- Completion
- 2021-09-21
Countries
- Hungary
Study Locations
More Related Trials
-
Comparison of Visual Outcomes After Implantation of the POD FT and the POD F
NCT04943809 ·Status: COMPLETED
-
Premium Trifocal IOL Comparative Analysis
NCT04875455 ·Status: COMPLETED ·Phase: NA
-
Implantation of a Trifocal Hydrophobic IOL in Patients That Underwent Refractive Surgery
NCT04054427 ·Status: WITHDRAWN ·Phase: NA
-
Clinical Investigation of the Multifocal IOL POD F GF in Cataracteous Eyes
NCT04699266 ·Status: COMPLETED ·Phase: NA
-
Clinical Study to Investigate Visual Performance of IOL: FineVision HP
NCT03027024 ·Status: COMPLETED ·Phase: NA
-
Clinical Study to Compare Visual Performance of Two Trifocal IOLs
NCT03347981 ·Status: COMPLETED ·Phase: NA
-
Safety and Efficacy of a Trifocal Intraocular Lens (IOL) POD L GF in Comparison With a Multifocal and a Monofocal IOL
NCT04005651 ·Status: COMPLETED ·Phase: NA
-
Clinical Outcomes of MICROPURE and PodEye Monofocal Intraocular Lenses
NCT03796624 ·Status: COMPLETED ·Phase: NA
-
Comparison of Viusal Outcomes After Implantation of the POD 26% FineVision Toric (PhysIOL) and POD 26% Toric (PhysIOL)
NCT02426385 ·Status: WITHDRAWN
-
Head-to-Head Comparison of Five Enhanced Depth of Focus IOLs and One Monofocal IOL
NCT07051720 ·Status: RECRUITING ·Phase: NA
-
Visual and Refractive Outcomes of a New Diffractive Trifocal Toric Intraocular Lens
NCT04940793 ·Status: COMPLETED
-
A Comparison of Visual Function After Bilateral Implantation of Presbyopia-correcting Intraocular Lenses (IOLs)
NCT01166971 ·Status: COMPLETED ·Phase: PHASE4
-
A Comparison of FineVision Intraocular Lenses vs Symfony Intraocular Lenses
NCT03974451 ·Status: COMPLETED ·Phase: NA
-
PMCF Study on Monofocal Toric IOL (PODEYE TORIC) in Europe (PHY2104)
NCT04987216 ·Status: COMPLETED ·Phase: NA
-
Visual Acuity After the Combined Binocular Implantation of +2.0 Diopters and +3.0 Diopters Oculentis Multifocal Intraocular Lenses.
NCT02633228 ·Status: COMPLETED ·Phase: PHASE4
-
Pilot Study With a Diffractive Trifocal IOL (POD AY 26P FineVision)
NCT02042755 ·Status: COMPLETED
-
Clinical Study to Investigate Visual Performance of a Hydrophobic Monofocal IOL After Bilateral Implantation
NCT03423524 ·Status: COMPLETED ·Phase: NA
-
Outcomes of Bilateral Implantation of an Enhanced Monofocal Intraocular Lens
NCT06118944 ·Status: COMPLETED ·Phase: NA
-
Comparative Analysis of the Visual Performance and Patient Satisfaction After Cataract Surgery With Implantation of a Medicontur Monofocal (877PAY) or a Medicontur Extended Depth of Focus (877PEY) IOL
NCT06642779 ·Status: COMPLETED
-
To Compare Postoperative Horizontal Position Stability of the CT LUCIA 611P and the CT ASPHINA 409MP
NCT04036149 ·Status: COMPLETED ·Phase: NA
-
PMCF Study on Monofocal Toric IOL (PODEYE TORIC) in Asia
NCT04778501 ·Status: COMPLETED ·Phase: NA
-
Comparative Study of 2 Multifocal Intraocular Lenses in Heidelberg
NCT06327347 ·Status: RECRUITING ·Phase: NA
-
Clinical Outcomes With Bilateral Implantation of Odyssey IOLs
NCT06550375 ·Status: COMPLETED
-
Prospective Evaluation of Visual Outcomes With Tecnis One-Piece Multifocal Intraocular Lenses Compared With Patients Previously Implanted With Crystalens Aspheric Optic (AO)
NCT01191229 ·Status: COMPLETED ·Phase: PHASE4
-
Accommodation Measurements After Bilateral Implantation of an Aspheric Accommodating Lens and Monofocal Aspheric Lenses
NCT01241279 ·Status: TERMINATED ·Phase: PHASE4