Ultra-low-dose CACS in a Large Population
NCT03637231 · Status: TERMINATED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 301
Last updated 2022-11-14
Summary
Radiation exposure to patients from CT for CAC scoring has steadily decreased in recent years. This is mainly achieved through lowering tube currents alongside with the introduction of iterative reconstruction algorithms which allow compensating for increased image noise. However, the greatest radiation dose reduction can be obtained by reducing peak tube voltage. Yet lowering peak tube voltage remains challenging because tissue attenuation is closely related to photon energy, thus rendering the established thresholds for calculating CAC scores (i.e. Agatston scores) incomparable if peak tube voltages other than the standard 120 kilovolt peak (kVp) are applied. The investigators have developed novel tube-adapted thresholds for CAC scoring by CT at 80 kVp and 70-kVp tube voltage and have shown that these novel thresholds are valid, yielding results closely comparable to the standard 120-kVp protocol. The present study aims to optimize application of such low-dose scans in a general population through assessment of the impact of physiological patient parameters on image parameters such as image noise which per se may impact the accuracy and feasibility of ultra-low-dose CAC scoring with reduced tube voltage. Furthermore, the prognostic performance of such low-dose CAC scoring will be elucidated.
Conditions
Interventions
- DIAGNOSTIC_TEST
-
Ultra low-dose CTAC
All patients undergo two non-contrast enhanced CT scans with standard dose (i.e. 120 kVp), one with 80 kVp and one with 70 kVp.
Sponsors & Collaborators
-
University of Zurich
lead OTHER
Study Design
- Allocation
- NA
- Purpose
- DIAGNOSTIC
- Masking
- NONE
- Model
- SEQUENTIAL
Eligibility
- Min Age
- 18 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2018-07-05
- Primary Completion
- 2021-10-25
- Completion
- 2021-10-25
Countries
- Switzerland
Study Locations
More Related Trials
-
Development of Novel Imaging Markers Predicting the Progression of Abdominal Aortic Aneurysm Using 3D Computed Tomography
NCT04333641 ·Status: COMPLETED
-
Patient Tailored Contrast Volume for Preoperative CT Angiography of the Aorta
NCT05716568 ·Status: COMPLETED ·Phase: NA
-
CCTA-guided Ultraselective Invasive Coronary Angiography
NCT04907786 ·Status: UNKNOWN
-
Development of Ultra-Low Dose CT Based Screening for Aortic Aneurysms
NCT03479164 ·Status: COMPLETED ·Phase: NA
-
Ultra-low Dose Contrast for Endovascular Procedures
NCT06835127 ·Status: COMPLETED
-
Impact of Aortic Geometry on Vascular Remodeling After Stent Implantation in Coarctation of the Aorta
NCT07131111 ·Status: NOT_YET_RECRUITING
-
A Prospective Analysis on the Expansion Rates of Abdominal Aortic Aneurysms
NCT02604303 ·Status: UNKNOWN
-
Aortic Calcium: Epidemiology and Progression -- Ancillary to MESA
NCT00059124 ·Status: COMPLETED
-
Endoprosthesis Treatment Effects on Human Abdominal Aorta Aneurysms (AAA) Metabolic Activity
NCT01253252 ·Status: COMPLETED ·Phase: NA
-
Safety, Efficacy, Longitudinal Costs and Patient-Centered Outcomes Using a TAAA Debranching Device
NCT03637374 ·Status: TERMINATED ·Phase: NA
-
Non-invasive Aortic Aneurysm Tissue Characterization Using Wall Viscoelasticity
NCT04150653 ·Status: UNKNOWN
-
Screening for Abdominal Aortic Aneurysms in the General Practice by Ultraportable Ultrasound
NCT05617326 ·Status: RECRUITING ·Phase: NA
-
Thoracoabdominal Aortic Aneurysms
NCT06267573 ·Status: NOT_YET_RECRUITING
-
Prognostic Impact of Chronic Total Occlusions
NCT02084888 ·Status: COMPLETED
-
Feasibility of Continuous Noninvasive Finger Arterial Blood Pressure Measurement for Detection and Staging of Aortic Stenosis
NCT03088787 ·Status: UNKNOWN
-
Autonomic Testing in Subclinical Carotid Atherosclerosis
NCT02726321 ·Status: COMPLETED
-
Evaluation of Predictors of Aortic Aneurysm Growth and Rupture
NCT02022436 ·Status: COMPLETED ·Phase: PHASE2
-
Advanced MRI in AAA
NCT03138434 ·Status: TERMINATED
-
Using US to Evaluate Aortic Aneurysm Size Based on 3D Co-registration to Previous CT Scan
NCT02717481 ·Status: UNKNOWN
-
Study of the Aorta Adaptations to Exercise in Triathletes During Sports Season (CoATri)
NCT03356301 ·Status: COMPLETED ·Phase: NA
-
4D Motion of the Aorta in the Chest and Simulated Wall Stress Distribution in Relation to Aortic Events
NCT04958083 ·Status: UNKNOWN ·Phase: NA
-
Evaluation of Visceral Function Following Endovascular Aortic Aneurysm Repair Using Branched Stent- Grafts
NCT01654133 ·Status: ENROLLING_BY_INVITATION ·Phase: NA
-
Radial Artery Spasm Leading to Occlusion in Patients Undergoing Coronary Angiogram Via Radial Access
NCT02577796 ·Status: WITHDRAWN
-
Cost-utility Analysis of Fenestrated Aortic Stents Versus Open Surgery for the Treatment of Complex Abdominal Aortic Aneurysms
NCT04671732 ·Status: COMPLETED
-
Robustness Check of Placement and Measurement Algorithms for Blood Flow Measurement on Common Carotid Artery
NCT05193760 ·Status: COMPLETED