Evaluation of the Patient-ventilator Asynchrony During Mechanical Ventilation for Pediatric Acute Respiratory Failure
NCT03138148 · Status: COMPLETED · Type: OBSERVATIONAL · Enrollment: 60
Last updated 2017-05-05
Summary
The synchronization between the patient and the ventilator is an essential objective during mechanical ventilation (MV). Maintaining the patient's respiratory activity during MV reduces ventilation pressures, improves oxygenation, and decreases sedation. In order to do this, the inspiratory or expiratory effort of the patient must be detected by the respirator' sensor systems, so that the assistance delivered by the respirator is coordinated with the patient's respiratory cycles. The usual systems do not actually detect the beginning of the effort but its result: variation in flow rate or pressure at the respirator circuit, which depends on the patient's respiratory mechanics and sensitivity of the sensor. This detection is currently imperfect, which generates asynchrony between the patient's needs and the assistance of the respirator. The asynchrony comprises the periods of delay between the beginning of the inspiration (or expiration) and the response of the respirator, but also of the unsuitable cycles: inspiratory efforts of the patient not detected by the respirator, or inversely triggering assistance in the absence of inspiration by the patient (self-initiation), or delivery of 2 cycles of assistance for a single inspiration (double triggering).
Asynchrony is a risk factor for prolonged mechanical ventilation in adults. Adult studies have shown that patient-ventilator asynchrony is common during MV, and is associated with prolonged MV duration. An association with length of stay in intensive care and in hospital was also observed. In children, patient-ventilator synchronization is more difficult to achieve than in adults due to a higher respiratory rate and smaller current volumes. The impact of patient-ventilator asynchrony on evolution has not been studied in pediatrics.
Patient-ventilator synchronization could be improved by the development of new ventilatory modes. The new NAVA (neurally adjusted ventilatory assist) ventilation mode detects the patient's breathing efforts earlier by monitoring the electrical activity of the diaphragm through the esophagus. This new mode seems to improve synchronization in children. NAVA ventilation may therefore be a step forward, but its clinical benefits remain to be seen.
The objective of this study is to evaluate the impact of patient-ventilator asynchrony on the duration of mechanical ventilation in children with acute respiratory failure.
Conditions
- Mechanical Ventilation
Interventions
- OTHER
-
Routine mechanical ventilation
Routine mechanical ventilation in PICU amid children with acute respiratory failure
Sponsors & Collaborators
-
St. Justine's Hospital
lead OTHER
Eligibility
- Min Age
- 1 Month
- Max Age
- 18 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2010-05-26
- Primary Completion
- 2012-10-17
- Completion
- 2017-01-06
Countries
- Canada
Study Locations
More Related Trials
-
Patient-ventilator Asynchrony in Patients With Brain Injury
NCT03212482 ·Status: COMPLETED
-
Evaluation of an Informative Intervention to the ICU Team About the Presence of Asynchronies in Mechanically Ventilated Patients: Effect Over Incidence Reduction
NCT02714751 ·Status: COMPLETED ·Phase: NA
-
Ventilation With ASV Mode in Children
NCT03930147 ·Status: COMPLETED ·Phase: NA
-
Clinical Impact of Patient-ventilator Asynchrony
NCT05796297 ·Status: COMPLETED
-
Patient-ventilator Synchronisation Study for Intensive Care Unit Patients
NCT03787173 ·Status: COMPLETED ·Phase: NA
-
Automated Detection of Patient Ventilator Asynchrony Using Pes Signal
NCT06186557 ·Status: RECRUITING
-
Outcome of Children Post Mechanical Ventilation
NCT05227989 ·Status: UNKNOWN
-
A Pilot Study Investigating the Detection of Episodes of Severe Patient-Ventilator Asynchrony
NCT04550871 ·Status: UNKNOWN
-
Weaning Children From Mechanical Ventilation:Computer-driven System Versus Usual Care
NCT00678912 ·Status: COMPLETED ·Phase: NA
-
Patient-Ventilator Dyssynchrony: How is the Effect of Management?
NCT00683072 ·Status: UNKNOWN
-
Non Invasive Mechanical Ventilation VERSUS Oxygen MASK
NCT03259854 ·Status: UNKNOWN ·Phase: NA
-
Study on the Patient-Ventilator Asynchrony Analysis Function
NCT06390917 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Retrospective Review of Mechanically Ventilated Patients Using a Continuous Data Collection System.
NCT02184208 ·Status: COMPLETED
-
Trial of Weaning by Synchronized Ventilation
NCT01376544 ·Status: COMPLETED ·Phase: NA
-
The Study Seeks to Determine Potential Correlations Between Ventilation and Hematological Alterations, Contributing to a Better Understanding of Its Physiological Effects and Optimizing Patient Management in Critical Care Settings.
NCT07030114 ·Status: NOT_YET_RECRUITING
-
The Use of Neurally Adjusted Ventilatory Assist (NAVA) Versus Pressure Support During Asynchrony in Children
NCT01159106 ·Status: UNKNOWN ·Phase: NA
-
A New Ultrasonographic Tool to Assess Pulmonary Strain in Patients Under One-lung Ventilation.
NCT03817918 ·Status: COMPLETED ·Phase: NA
-
Ventilator Asynchrony as a Predictor of Weaning Failure
NCT04735497 ·Status: COMPLETED
-
Treatment of Ventilator Associated Pneumonia in Pediatric Intensive Care Unit
NCT03294837 ·Status: UNKNOWN
-
Optimization of Ventilation Strategies in Preterm and Term Infants in a Single-center Intervention Study
NCT05512689 ·Status: COMPLETED ·Phase: NA
-
Impact of Humidification on Sleep Quality During Home Non Invasive Ventilation
NCT03561974 ·Status: COMPLETED ·Phase: NA
-
Pilot Study on Pairing Sedation Strategies and Weaning
NCT02219659 ·Status: COMPLETED ·Phase: NA
-
Diaphragm Injury and Dysfunction During Mechanical Ventilation
NCT03108118 ·Status: COMPLETED
-
Effort of Breathing Guided Ventilator Protocol
NCT02989246 ·Status: COMPLETED ·Phase: NA
-
Prediction of Outcome of Weaning From Mechanical Ventilation Using the Electrical Activity of the Diaphragm
NCT02539732 ·Status: UNKNOWN