Validity and Reliability of Optical Heart Rate Sensors
NCT05525000 · Status: COMPLETED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 32
Last updated 2023-10-16
Summary
To evaluate validity and reliability of consumer-grade optical heart-rate devices we aim to compare these devices with medical-grade ECG. The design includes an extended and practical validation protocol for consumer-grade optical heart rate devices in laboratory and ambulatory free-living conditions using a medical-grade ECG device as a criterion measure.
Conditions
- Health Care Utilization
Interventions
- DEVICE
-
Validation
The validation protocol consists of the following activities: Activities of daily living, Exercise test on the treadmill, Exercise test on the cycle ergometer, Free-living session
Sponsors & Collaborators
-
Salzburger Landeskliniken
collaborator OTHER -
Ludwig Boltzmann Institute for Digital Health and Prevention
lead OTHER
Study Design
- Allocation
- NA
- Purpose
- OTHER
- Masking
- NONE
- Model
- SINGLE_GROUP
Eligibility
- Min Age
- 35 Years
- Sex
- ALL
- Healthy Volunteers
- Yes
Timeline & Regulatory
- Start
- 2022-05-25
- Primary Completion
- 2023-01-01
- Completion
- 2023-01-18
Countries
- Austria
Study Locations
More Related Trials
-
Contactless Measurement of Heart Rate, Heart Rate Variability and Breathing Rate Using Remote Photoplethysmography
NCT05889832 ·Status: COMPLETED ·Phase: NA
-
Accuracy of Commercially Available Heart Rate Monitors in Athletes
NCT03612063 ·Status: COMPLETED ·Phase: NA
-
SpO2 System Accuracy Testing With Different Sensors
NCT01613222 ·Status: COMPLETED ·Phase: NA
-
Anonymized Data Collection From the CS6BP for Heart Arrythmias Measurements
NCT05723744 ·Status: COMPLETED ·Phase: NA
-
Study on Cardiac Output Evaluation Based on Wearable Monitoring Data
NCT06938893 ·Status: NOT_YET_RECRUITING
-
Validation of Software for Assessment of Atrial Fibrillation From Data Acquired by a Wearable Smartwatch
NCT04176926 ·Status: COMPLETED
-
Monitoring Health Care Workers at Risk for COVID-19 Using Wearable Sensors and Smartphone Technology
NCT04756869 ·Status: COMPLETED
-
Assessment of Physiological Parameters Measurements (Heart Rate, Respiratory Rate, and Oxygen Saturation) by Standard Acquisition System Compared Remote Photoplethysmography Imaging System l
NCT04660318 ·Status: UNKNOWN ·Phase: NA
-
Exploring the Relationship Between Heart Rate Variability (HRV), Training Load, and Endurance Performance
NCT06964100 ·Status: RECRUITING
-
Use of HRV Measuring Hearing-aid Device to Detect Acute Stress
NCT05485129 ·Status: UNKNOWN ·Phase: NA
-
A Validation Study of Selfie Technology for Assessment of Vital Signs
NCT05117762 ·Status: UNKNOWN
-
Development and Validation of a Telemonitoring System for High-risk Cardiovascular Patients
NCT05485532 ·Status: ACTIVE_NOT_RECRUITING
-
Estimation of Average and Beat-to-beat Heart Rate With a Novel Wrist-worn PPG Device in Surgery Patients
NCT03081793 ·Status: COMPLETED
-
Validity and Reliability of a Clinical Method for Assessment of Cardiorespiratory Fitness Using Seismocardiography
NCT05356871 ·Status: COMPLETED
-
A Study on the Effectiveness of the Application of an Artificial Intelligence Algorithm for Calibrating PPG With ECG to Improve the Accuracy of Atrial Fibrillation Burden Estimation
NCT06552468 ·Status: COMPLETED
-
Measuring Accuracy of Wristband for Registration of ECG RR-Intervals for One Hand, SenceBand in Comparison to Holter
NCT03747861 ·Status: COMPLETED ·Phase: NA
-
Wearable Technology for Hospital Inpatients
NCT02527408 ·Status: COMPLETED
-
Necklace-Shaped Sensor for Non-Invasive Remote Monitoring of Vitals
NCT02337790 ·Status: COMPLETED
-
Contactless Vital Signs Measurement Study (CVMS)
NCT05886686 ·Status: UNKNOWN
-
Suitability of Unobtrusive Bed Monitoring and Wrist-worn Heart Rate Monitor for Patient Monitoring
NCT03572751 ·Status: COMPLETED
-
CardioSenseSystem Compared Study Regarding Efficacy and Safety in the Monitoring of ECG
NCT03610529 ·Status: UNKNOWN ·Phase: NA
-
Modelling of Energy Expenditure From Heart Rate, Accelerometry and Other Physiological Parameters
NCT01209572 ·Status: COMPLETED ·Phase: NA
-
Evaluation of EarlySense Home Care Tele-monitoring Device -For Early Detection of Deterioration For Cardiac Patients at Home
NCT02659982 ·Status: COMPLETED
-
Remote Blood Pressure Monitoring With the Wearable SENBIOSYS Photoplethysmographic Device
NCT04379986 ·Status: COMPLETED ·Phase: NA
-
Integrated Telemonitoring and Nurse Support Evaluation
NCT01700218 ·Status: UNKNOWN ·Phase: NA