Use of a Bearable Continuous Interstitial Glucose Monitoring Device (GuardianR) During Teaching Sessions to Functional Insulin Therapy Concept in Patients Suffering From Type 1 Diabetes: Evaluation at 6 and 12 Months
NCT00682903 · Status: COMPLETED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 64
Last updated 2014-08-28
Summary
The objective of the project is to evaluate advantages from the use of a bearable continuous interstitial glucose monitoring device (GuardianR) during educative sessions of diabetic patients dedicated to functional insulin therapy teaching. This concept of intensified treatment is based on testing and explanation of simplified decision making algorithms to adapt insulin dose to every true life conditions. As self monitoring of capillary glucose level is needed to validate those algorithms, we postulate that using a device able to permanently control interstitial glucose readable by both medical team and patient himself (during the session and the 5 following days after discharge) could significantly improve safety and efficiency of such educative session.
Conditions
- Diabetes Complications
Interventions
- DEVICE
-
GuardianR
As self monitoring of capillary glucose level is needed to validate those algorithms, we postulate that using a device able to permanently control interstitial glucose readable by both medical team and patient himself (during the session and the 5 following days after discharge) could significantly improve safety and efficiency of such educative session.
Sponsors & Collaborators
-
Assistance Publique Hopitaux De Marseille
lead OTHER
Study Design
- Allocation
- RANDOMIZED
- Purpose
- DIAGNOSTIC
- Masking
- NONE
- Model
- PARALLEL
Eligibility
- Min Age
- 18 Years
- Max Age
- 70 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2008-01-31
- Primary Completion
- 2011-02-28
- Completion
- 2011-02-28
Countries
- France
Study Locations
More Related Trials
-
Obtain a Good Blood Glucose Control With the Paradigm Real Time System
NCT00441129 ·Status: COMPLETED ·Phase: NA
-
The Guardcontrol Trial: Study to Assess if Type 1 Diabetics Can Improve Using the Real-time Values of Guardian RT
NCT00111228 ·Status: COMPLETED ·Phase: NA
-
Glucose Counterregulation in Long Standing Type 1 Diabetes
NCT01474889 ·Status: COMPLETED ·Phase: NA
-
Study of Insulin Pump in Prevention of Low Glucose Events in Adults With Type 1 Diabetes at Risk of Severe Hypoglycemia
NCT02657213 ·Status: COMPLETED ·Phase: NA
-
A Pilot Study of Nocturnal Hypoglycemia Prevention in Type 1 Diabetes Using the Vigilant Diabetes Management Companion
NCT02906891 ·Status: TERMINATED ·Phase: NA
-
Comparison of an Artificial Pancreas Versus Threshold Low Glucose Suspend in Type 1 Diabetic Children
NCT02509429 ·Status: COMPLETED ·Phase: PHASE2
-
Telemedicine Program in Type 1 Diabetes and CSII
NCT02790645 ·Status: COMPLETED ·Phase: NA
-
Blood Glucose Target Before and During Exercise in Adults With Type 1 Diabetes Using an Artificial Pancreas
NCT05821322 ·Status: TERMINATED ·Phase: NA
-
CGM Intervention in Teens and Young Adults With Type 1 Diabetes (T1D)
NCT03263494 ·Status: COMPLETED ·Phase: PHASE3
-
Clinical Effects of Intermitent Continuous Glucose Monitoring in Type 1 Diabetes
NCT05095610 ·Status: COMPLETED
-
Long Term CGM Treatment in Patients With Type 1 Diabetes Treated With Insulin Injections
NCT02465411 ·Status: COMPLETED ·Phase: NA
-
A Study of LY2605541 and Glargine in Participants With Type 1 Diabetes
NCT01769404 ·Status: COMPLETED ·Phase: PHASE1
-
Comparison of SmartGuard vs Temp Target in Patients With Type 1 Diabetes Users of Advanced Hybrid Closed Loop System (AHCL) in Anaerobic Physical Activity.
NCT06728423 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Safety and Efficacy of RT-CGMS in Patients With Type 1 Diabetes Mellitus Treated With an Implantable Pump
NCT00501072 ·Status: COMPLETED ·Phase: NA
-
Interest of SmartGuard Technology (Predictive System for Stopping Insulin Before Hypoglycemia) in Children With Type 1 Diabetes Treated With Insulin Pump
NCT03882463 ·Status: COMPLETED ·Phase: NA
-
Impact of Functional Insulinotherapy on Blood Glucose Variability Indicators in Patients With Type 1 Diabetes
NCT00973492 ·Status: UNKNOWN
-
Real-Time Continuous Glucose Monitoring in Pre-School Children With Type-1 Diabetes Mellitus
NCT01016457 ·Status: UNKNOWN ·Phase: PHASE4
-
The Effects of CGM and Connected Pen in T2DM Treated With Multiple Daily Insulin Injections
NCT06311019 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
T1 Diabetes Hypoglycemia Prevention Pilot
NCT02682940 ·Status: TERMINATED ·Phase: NA
-
Effects of a Remote Patient Monitoring Protocol on Glycemic Control in Adolescents With Type 1 Diabetes
NCT03466398 ·Status: WITHDRAWN ·Phase: NA
-
Blood Glucose Variability and Insulin Action During Menstrual Cycle in Females With Type 1 Diabetes
NCT02693938 ·Status: COMPLETED ·Phase: NA
-
Study of MiniMed™ 640G Insulin Pump With SmartGuard™ in Prevention of Low Glucose Events in Adults With Type 1 Diabetes
NCT02733991 ·Status: COMPLETED ·Phase: NA
-
Prevention of Severe Hypoglycemia in Type 1 Diabetes
NCT00360984 ·Status: COMPLETED ·Phase: PHASE4
-
Continue Glucose Monitoring Before Insulin Pump
NCT02813421 ·Status: COMPLETED ·Phase: NA
-
Continuous Ketone Monitoring in People With Type 1 Diabetes Using SGLT2 Inhibitors
NCT06753994 ·Status: RECRUITING ·Phase: PHASE1