FIND CAN Trial: "CF-172"
NCT03033641 · Status: COMPLETED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 25
Last updated 2025-02-03
Summary
The purpose of this feasibility study is to further explore characteristics of ablation targets identified by CARTOFINDER 4D LAT Algorithm in subjects with persistent atrial fibrillation and to assess the acute outcome of CARTOFINDER Guided Ablation in terms of the termination of atrial fibrillation to either Normal Sinus Rhythm or Atrial Tachycardia.
Conditions
- Persistent Atrial Fibrillation
Interventions
- DEVICE
-
Ablation procedure
All enrolled subjects who have ablation targets identified will undergo CARTOFINDER guided ablation (CFGA) followed by PVI. Subjects will be followed per the protocol schedule. Subjects who have no ablation target identified on the baseline CARTOFINDER map will undergo ablation per the institution's standard of care and be followed for 7 days for safety monitoring, then exit from the study.
Sponsors & Collaborators
-
Biosense Webster, Inc.
lead INDUSTRY
Study Design
- Allocation
- NA
- Purpose
- TREATMENT
- Masking
- NONE
- Model
- SINGLE_GROUP
Eligibility
- Min Age
- 18 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2016-12-05
- Primary Completion
- 2017-05-04
- Completion
- 2017-08-30
More Related Trials
-
Evaluation of Conventional Ablation With or Without Focal Impulse and Rotor Modulation to Eliminate Human AF
NCT02456233 ·Status: COMPLETED ·Phase: NA
-
Left Atrial Posterior Wall and Mitral Isthmus PF Ablation in Non-Paroxysmal AF Patients
NCT06801392 ·Status: RECRUITING
-
High-Density (HD) Wave Mapping in Subjects With Atrial Fibrillation as a Predictor of Recurrence After a Single Ablation Procedure Using a PVI-Only Strategy
NCT03882021 ·Status: COMPLETED ·Phase: NA
-
AF Substrate Mapping and Guided Ablation
NCT02571218 ·Status: COMPLETED ·Phase: NA
-
Safety and Effectiveness of TactiCath™ Contact Force, Sensor Enabled™ (TactiCath SE) Catheter for Ablation of Drug Refractory, Symptomatic, Persistent Atrial Fibrillation
NCT03650556 ·Status: COMPLETED ·Phase: NA
-
Clinical Study of the CardioFocus Endoscopic Ablation System - Adaptive Contact (EAS-AC) for the Treatment of Symptomatic Atrial Fibrillation
NCT00971204 ·Status: COMPLETED ·Phase: PHASE2
-
Using a Novel Balloon-shaped Large-Focal Pulsed Field Ablation Catheter in Persistent Atrial Fibrillation
NCT07294742 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
CardioFocus vs. Contact Force Guided Pulmonary Vein Isolation in Paroxysmal Atrial Fibrillation
NCT03056222 ·Status: COMPLETED ·Phase: NA
-
Prospective Evaluation of Open Irrigated Ablation Catheters With High Resolution Mapping to Treat Paroxysmal Atrial Fibrillation
NCT03729830 ·Status: COMPLETED
-
Substrate Versus Trigger Ablation for Paroxysmal Atrial Fibrillation
NCT02169037 ·Status: UNKNOWN ·Phase: NA
-
Hybrid Characterization of Driver Sites During Atrial Fibrillation and Sinus Rhythm
NCT05077670 ·Status: UNKNOWN
-
Anatomical Navigation for Guided Electrophysiology in AFL and AFib
NCT07210151 ·Status: RECRUITING ·Phase: NA
-
A Study Assessing Arrhythmia Mapping With a Multi-Electrode Mapping Catheter
NCT07116525 ·Status: RECRUITING ·Phase: NA
-
A Fib Clinic of the Future Using KardiaPro Platform for Chronic Care of Patients With AF After Ablation Procedure
NCT03557034 ·Status: COMPLETED ·Phase: NA
-
FLExAbility Sensor Enabled Substrate Targeted Ablation for the Reduction of VT Study
NCT03490201 ·Status: COMPLETED ·Phase: NA
-
Single Center Pilot Study Using the ECGenius System to Collect Electrogram Data to Test an Ablation Impact Algorithm
NCT05458648 ·Status: COMPLETED
-
STrategies for Catheter Ablation of peRsistent Atrial Fibrlllation
NCT04428944 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Evaluation of a Multi-electrode Linear Type Catheter (D-1368-01-SI)
NCT02991313 ·Status: COMPLETED ·Phase: NA
-
TactiCath® Contact Force Ablation Catheter Study for Atrial Fibrillation Post Approval Study
NCT02310100 ·Status: COMPLETED ·Phase: NA
-
CARTO-Finder Guided Ablation Versus Multiscale Entropy Guided Ablation in Persistent Atrial Fibrillation
NCT05454111 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Atrial Fibrillation Progression Trial
NCT01570361 ·Status: TERMINATED ·Phase: PHASE4
-
IntellaTip MiFi XP Ablation Catheter Trial
NCT01730807 ·Status: COMPLETED ·Phase: NA
-
Comparison of Two Pulmonary Vein Ablation Techniques for Persistent AF
NCT03295422 ·Status: UNKNOWN ·Phase: NA
-
Left Atrial Arrhythmia Substrate Identification After Confirmed durABLE Pulmonary Vein Isolation
NCT04111731 ·Status: COMPLETED ·Phase: NA
-
Determination of Catheter Contact by Evaluation of Microelectrode Near-Field Signals
NCT02080975 ·Status: COMPLETED ·Phase: NA