Posterior CAD/CAM Cobalt-chromium Alloy Single Crowns: 4-year Prospective Clinical Study

NCT02956174 · Status: COMPLETED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 89

Last updated 2016-11-08

No results posted yet for this study

Summary

Objectives - To evaluate the 4-year clinical outcomes of ceramic veneered Computer Aided Design/Computer Aided Manufacturing (CAD/CAM) Co-Cr single crowns supported by natural teeth in posterior regions.

Material and methods - Eighty-nine patients were provided with 120 ceramic veneered CAD/CAM Co-Cr single crowns replacing either premolars and molars. Specific inclusion criteria were needed and tooth preparations were standardized and performed by 2 expert prosthodontists. CAD/CAM Co-Cr frameworks were fabricated and veneered with ceramics. The restorations were cemented using a eugenol-free zinc oxide luting agent. The patients were recalled after 1, 6, 12, 24, 36 and 48 months. The survival and success of the restorations were evaluated. The technical and esthetic outcomes were examined using the United States Public Health Service criteria. The biologic outcomes were analyzed at abutment and contralateral teeth and descriptive statistics were performed.

Conditions

  • Single Tooth Lost

Interventions

DEVICE

Co-Cr single crown

OTHER

Periodontal parameters

Sponsors & Collaborators

  • Federico II University

    lead OTHER

Study Design

Allocation
NON_RANDOMIZED
Purpose
TREATMENT
Masking
SINGLE
Model
PARALLEL

Eligibility

Min Age
21 Years
Max Age
68 Years
Sex
ALL
Healthy Volunteers
No

Timeline & Regulatory

Start
2012-05-31
Primary Completion
2016-07-31

More Related Trials