User Performance Evaluation of Contour® Plus One, Accu-Chek® Performa Connect, FreeStyle Optium Neo and OneTouch® Select Plus Blood Glucose Monitoring Systems Following ISO 15197:2013; EN ISO 15197:2015

NCT02916576 · Status: COMPLETED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 140

Last updated 2017-02-14

No results posted yet for this study

Summary

The user performance evaluation shows whether people with diabetes are able to obtain accurate measurement results with a blood glucose monitoring system. In this study, user performance evaluation will be performed for Contour Plus One (Ascensia Diabetes Care GmbH), Accu-Chek Performa Connect (Roche Diabetes Care GmbH), FreeStyle Optium Neo (Abbott Diabetes Care Inc.), OneTouch Select Plus (LifeScan Europe) based on ISO 15197:2013; EN ISO 15197:2015, clause 8.

For each BGMS, measurement procedures for user performance evaluation will be performed with 1 test meter and 1 reagent system lot by the study subjects.

The same meter and an additional test meter will be used for double measurements performed by study personnel (with the same reagent system lot used by subjects).

Conditions

Interventions

DEVICE

Blood-Glucose Monitoring Systems for self-testing

This is a user performance study, that is intended to show whether people with diabetes are able to obtain accurate measurement results with a blood glucose monitoring system (BGMS). The subjects' measurement technique (e.g. applying blood onto the system reagent, reading the result) will be observed and documented by study personnel. Immediately after the measurement by the subject, the study personnel will perform a measurement with the same test meter. Measurement results obtained by the subjects with the BGMS will be compared to measurement results obtained with the comparison method. Sample collection for the comparison measurement will be performed by study personnel within 5 min after the subject's measurement with the test meter. The samples will be collected from the subjects' skin puncture (if possible), an additional skin puncture (if required) will be documented. An additional skin puncture will be performed by study personnel with single-use lancing devices.

Sponsors & Collaborators

  • Ascensia Diabetes Care

    collaborator INDUSTRY
  • Institut für Diabetes-Technologie Forschungs- und Entwicklungsgesellschaft mbH an der Universität Ulm

    lead OTHER

Eligibility

Min Age
18 Years
Sex
ALL
Healthy Volunteers
Yes

Timeline & Regulatory

Start
2016-09-30
Primary Completion
2016-12-31
Completion
2017-02-28

Countries

  • Germany

Study Locations