Blind Gastric Tube Placement: Incidence of Malposition Confirmed by Ultrasonography
NCT03430908 · Status: COMPLETED · Type: OBSERVATIONAL · Enrollment: 166
Last updated 2019-06-18
Summary
This is a prospective, single-arm cohort, observational study to determine the incidence of gastric tube malposition during blind insertion by an anesthesia provider.
Conditions
- Anesthesia
Interventions
- OTHER
-
Blind Gastric Tube Placement
The provider will be blinded to the ultrasound imaging throughout the entire insertion. This blind insertion process is the standard of care currently practiced at MSKCC. After the provider verbalizes that they have completed the insertion the investigators will stop the ultrasound imaging and complete the data form. No information will be given to the provider about the location of the gastric tube as to not deviate from the standard of care. The only time that information will be provided to the practitioner inserting the tube will be if the tube is positioned in any of the following positions that are thought to be potentially injurious if unrecognized. These positions include intrapulmonary, cranial, nasal or oral pharyngeal placements and diverticular or hiatal hernia sac coiling and remain unrecognized by the practitioner. These are considered positions that have the potential for injury and therefore will be divulged to prevent ensuing injury.
Sponsors & Collaborators
-
Memorial Sloan Kettering Cancer Center
lead OTHER
Principal Investigators
-
Luis E Tollinche, MD · Memorial Sloan Kettering Cancer Center
Eligibility
- Min Age
- 18 Years
- Sex
- ALL
- Healthy Volunteers
- Yes
Timeline & Regulatory
- Start
- 2017-12-22
- Primary Completion
- 2019-06-17
- Completion
- 2019-06-17
Countries
- United States
Study Locations
More Related Trials
-
Accuracy of Ultrasonography in Confirming Correct Positioning of Nasogastric Tube in the Intensive Care Setting
NCT06693219 ·Status: COMPLETED ·Phase: NA
-
SUBclavian Central Venous Catheters Guidance and Examination by UltraSound
NCT01888094 ·Status: COMPLETED ·Phase: PHASE2/PHASE3
-
Ultrasound to Check the Position of the Nasogastric Tube
NCT06635915 ·Status: RECRUITING ·Phase: NA
-
Comparison of Three Methods for NG Tube Placement
NCT03699306 ·Status: COMPLETED ·Phase: NA
-
Gastric Ultrasound Feeding Tube Placement Confirmation Study
NCT06595537 ·Status: RECRUITING
-
Bedside Ultrasound by Anesthesiologists for Screening Deep Venous Thrombosis
NCT03443310 ·Status: COMPLETED ·Phase: NA
-
Ultrasound Guided Peripheral IV Insertion
NCT03841864 ·Status: COMPLETED ·Phase: NA
-
Nasogastric Tube Placement on Intubated Patient: Two-Finger Method vs Reverse Sellick's Maneuver
NCT03134287 ·Status: COMPLETED ·Phase: NA
-
Feasibility and Safety of Ultrasound Guided Installation Central Subclavian Catheter Through Supraclavicular Way
NCT02809664 ·Status: UNKNOWN
-
Comparative Evaluation of Ultrasound Guided Supraclavicular and Infraclavicular Subclavian Venous Catheterizations in Adult Patients Undergoing Major Surgeries
NCT02925715 ·Status: COMPLETED ·Phase: PHASE4
-
Longitudinal or Transverse Orientation of Ultrasound Probe in Minimally Invasive Venous Surgery.
NCT04036734 ·Status: COMPLETED ·Phase: NA
-
Ultrasound for Confirmation of Gastric Tube Placement in Critically Ill Patients Under Invasive Mechanical Ventilation
NCT04795895 ·Status: TERMINATED ·Phase: NA
-
Ultrasound Guidance Versus Anatomical Landmarks for Subclavian Vein Catheterization
NCT04690296 ·Status: COMPLETED ·Phase: NA
-
Ultrasound to Investigate Tip Dislodgment of Epicutaneous-caval Catheter.
NCT06438289 ·Status: COMPLETED
-
Ultrasound-guided Axillary Artery vs Femoral Artery Cannulation.
NCT02801825 ·Status: COMPLETED ·Phase: NA
-
Ultrasound-assisted Thoracic Epidural Catheter Insertion
NCT03890640 ·Status: COMPLETED ·Phase: NA
-
Supraclavicular Fossa US View for Catheter Positioning in Right Subclavian Central Venous Catheterization
NCT03812757 ·Status: COMPLETED
-
Comparison of Different Methods of Nasogastric Tube Insertion in Anesthetized and Intubated Patients
NCT02557204 ·Status: COMPLETED ·Phase: NA
-
UGIST: Ultrasound Guided Internal Jugular Short-Term Central Venous Catheters Tunneling
NCT00639197 ·Status: UNKNOWN ·Phase: NA
-
Facilitation of NGT Insertion
NCT02764632 ·Status: COMPLETED ·Phase: NA
-
Comparison of Axillary Versus Subclavian Vein Strategies for Central Venous Catheterization Under Continuous Ultrasound Guidance
NCT01543360 ·Status: COMPLETED ·Phase: NA
-
Effect of Ultrasound-guided Insertion on Peripheral Catheters Related Complications.
NCT05284422 ·Status: UNKNOWN ·Phase: NA
-
Comparing Palpation Guided and Ultrasound Guided Arterial Line Placement
NCT01757314 ·Status: TERMINATED
-
Ultrasonography Confirmation of Feeding Tube Placement
NCT05307900 ·Status: COMPLETED ·Phase: NA
-
A Trial to Study the Influence of Ultrasound Guidance on the Complications of Central Catheter
NCT01154465 ·Status: UNKNOWN ·Phase: NA