Efficacy, Safety and Efficiency of the nMARQ Pulmonary Vein Isolation System in Paroxysmal Atrial Fibrillation
NCT02268539 · Status: COMPLETED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 11
Last updated 2020-12-22
Summary
This is a pilot study designed to investigate the effectiveness of the nMARQ Pulmonary Vein Isolation system in the treatment of Paroxysmal Atrial Fibrillation (AF) at different ablation settings.
AF is a common condition which causes a fast and erratic heartbeat. There are estimated to be 50,000 new cases diagnosed per year in the UK. The fast heart beat can cause symptoms such as palpitations, lightheadedness, chest pains, shortness of breath and fatigue.
Catheter ablation is a technique used for the control of AF. In this procedure a catheter (a long thin wire) is passed into the chambers of the heart via a large blood vessel in a leg. The tip of the catheter can destroy tiny sections of heart tissue that may be the source or trigger of the abnormal electrical impulses. One of the challenges of AF ablation is to maximize success rates, as such there is currently rapid advances in technology to carry out this procedure.
Different catheters exist which deliver this energy in different ways. This study uses one such system to perform this procedure. It is called the nMARQ system for Pulmonary Vein Isolation produced by Biosense Webster. Currently this system is used in practice in the UK for patients with this medical condition.
What we seek to research is when ablating what is the optimum setting to perform ablation at. There is currently no data to guide best clinical practice in this area.
Conditions
- Paroxysmal Atrial Fibrillation
Interventions
- PROCEDURE
-
ablation
Ablation ranging from 20-25 watts / 30-45 seconds
Sponsors & Collaborators
-
Anglia Ruskin University
collaborator OTHER -
Mid and South Essex NHS Foundation Trust
lead OTHER
Principal Investigators
-
Stuart Tan, MB BC, MRCP · Mid and South Essex NHS Foundation Trust
Study Design
- Allocation
- RANDOMIZED
- Purpose
- TREATMENT
- Masking
- NONE
- Model
- FACTORIAL
Eligibility
- Min Age
- 18 Years
- Max Age
- 80 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2014-02-01
- Primary Completion
- 2017-12-31
- Completion
- 2017-12-31
Countries
- United Kingdom
Study Locations
More Related Trials
-
3D-Guided Pulsed Field Ablation for Paroxysmal AF
NCT07023237 ·Status: NOT_YET_RECRUITING
-
Ectopy Triggering Ganglionated Plexus Ablation to Prevent Atrial Fibrillation
NCT02487654 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Cardioneuroablation vs Pulmonary Vein Isolation in Treatment of Paroxysmal Atrial Fibrillation
NCT06058468 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
A Study of Assessment on Safety and Effectiveness of BWI Pulsed Field Ablation With OMNYPULSE Catheter for the Treatment of Paroxysmal Atrial Fibrillation (PAF)
NCT06455098 ·Status: RECRUITING ·Phase: NA
-
Substrate Versus Trigger Ablation for Paroxysmal Atrial Fibrillation
NCT02169037 ·Status: UNKNOWN ·Phase: NA
-
Inflammatory Response Following " Pulsed Field Ablation " vs. Radiofrequency Ablation-2
NCT06160076 ·Status: COMPLETED
-
Pulmonary Veins Circular Ablation Catheter Evaluation for Atrial Fibrillation
NCT02107027 ·Status: UNKNOWN ·Phase: NA
-
Pulsed Field Ablation With Concomitant Radiofrequency Cardioneuroablation in Patients With Paroxysmal Atrial Fibrillation
NCT07171463 ·Status: RECRUITING ·Phase: NA
-
Safety-and-effectiveness Clinical Evaluation of Nanosecond-pulse Ablation for Atrial Fibrillation
NCT06039722 ·Status: COMPLETED ·Phase: NA
-
Evaluation of the Efficacy of Pulmonary Vein Isolation by Pulsed-field Ablation in Persistent Atrial Fibrillation: a Multicenter Study With Follow-up by Implantable Cardiac Monitor
NCT06985901 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Safety and Efficacy Study of Amniotic Membrane Patch to Treat Postoperative Atrial Fibrillation
NCT02193321 ·Status: WITHDRAWN ·Phase: PHASE1/PHASE2
-
Clinical Value of Linear Ablation Without Pulmonary Vein Isolation in Persistent Atrial Fibrillation
NCT05468528 ·Status: UNKNOWN ·Phase: NA
-
Oesophageal Pacing to Check Left Atrial Posterior Wall Isolation
NCT05086861 ·Status: COMPLETED ·Phase: NA
-
Contact Force Guided Ablation Versus Conventional Pulmonary Vein Isolation for Paroxysmal Atrial Fibrillation
NCT02816268 ·Status: COMPLETED ·Phase: NA
-
A Study for Treatment of Paroxysmal Atrial Fibrillation (PAF) by Pulsed Field Ablation (PFA) System With Irreversible Electroporation (IRE)
NCT04524364 ·Status: COMPLETED ·Phase: NA
-
Ganglionated Plexus Ablation For Treatment of Atrial Fibrillation
NCT02267889 ·Status: COMPLETED ·Phase: NA
-
Left Atrial Arrhythmia Substrate Identification After Confirmed durABLE Pulmonary Vein Isolation
NCT04111731 ·Status: COMPLETED ·Phase: NA
-
Prospective Evaluation of CT Guided Ablation of Cardiac Ganglionated Plexi
NCT04642976 ·Status: COMPLETED
-
Unexcitability Along the Ablation as an Endpoint for Atrial Fibrillation Ablation
NCT01724437 ·Status: COMPLETED ·Phase: NA
-
Pulsed Field Ablation During Left Atrial Appendage Occlusion: A Randomised Controlled Trial
NCT06334250 ·Status: WITHDRAWN ·Phase: NA
-
Study on the Ablation of Persistent Atrial Fibrillation Using Pulsed Electric Fields Under Different Surgical Procedures
NCT06671197 ·Status: NOT_YET_RECRUITING
-
Left Atrial Posterior Wall and Mitral Isthmus PF Ablation in Non-Paroxysmal AF Patients
NCT06801392 ·Status: RECRUITING
-
CellFX® Nanosecond Pulsed Field Ablation (PFA) 360 Catheter Ablation System for Treatment of Atrial Fibrillation
NCT06696170 ·Status: RECRUITING ·Phase: NA
-
Prospective Evaluation of Open Irrigated Ablation Catheters With High Resolution Mapping to Treat Paroxysmal Atrial Fibrillation
NCT03729830 ·Status: COMPLETED
-
Clinical Evaluation of the Blazer Open-Irrigated Ablation Catheter for the Treatment of Paroxysmal Atrial Fibrillation
NCT01687166 ·Status: COMPLETED ·Phase: NA