Can Capillary Refill Time Variation During Passive Leg Raising Predict Fluid Responsiveness
NCT02248025 · Status: COMPLETED · Type: OBSERVATIONAL · Enrollment: 34
Last updated 2017-05-05
Summary
Fluid responsiveness in a context of circulatory failure can be assessed by different way. Microcirculatory evaluation to assess fluid responsiveness could be interesting, but the available device are expensive and the analysis are delayed. Capillary refill time (CRT) is hampered by its variability. The investigators have developed a method to standardize the pressure, the length of compression and a computerized analysis to calculate the capillary refill time. This method enables accurate measure of CRT.
The investigators will study if CRT variation induced by a passive leg raising (PLR) can predict CRT after a 500 ml Fluid Load.
About thirty patients in circulatory failure with a continuous cardiac output monitoring for whom, the attending physician has decided a fluid load, will be included. hemodynamic parameters (arterial pressure, venous pressure, cardiac output), metabolic parameters (arterial and venous blood gas and lactate), microcirculatory parameters (assessed by sublingual video-microscopy) and capillary refill time measured on the thorax and on the gingival area will be recorded. Data collection will be made before and after a passive leg raising and after a 500 ml fluid load of crystalloids.
Patients will be aposteriori sorted in two groups: responders and non responders, defined by the reduction of CRT after the fluid load. The diagnosis ability of the CRT variation after PLR to predict in which group each patient is classified will be investigate and receiver operative characteristic curve will be built. These results will be compared to the metabolic response, the macrocirculatory response, and the microcirculatory response.
Conditions
- Circulatory Failure
Interventions
- OTHER
-
Observational study: No special intervention will be made.
No special intervention will be made, only data will be collected before, and after a passive leg raising and a fluid challenge decided and performed by the attending physician.
Sponsors & Collaborators
-
Hopital Louis Pradel
lead OTHER
Eligibility
- Min Age
- 18 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2014-09-30
- Primary Completion
- 2017-05-31
- Completion
- 2017-05-31
Countries
- France
Study Locations
More Related Trials
-
Passive Leg Raising for Predicting Fluid Responsiveness in VA-ECMO Assisted Patients
NCT04984603 ·Status: UNKNOWN
-
Assessment of Fluid Responsiveness in Patients After Cardiac Surgery
NCT02571465 ·Status: COMPLETED
-
Use of Mini-fluid Challenge for Fluid Responsiveness Prediction During One-lung Ventilation
NCT02858115 ·Status: COMPLETED
-
Fluid Responsiveness With Passive Leg Raising in Patients Undergoing Coronary Artery Bypass Surgery
NCT07245485 ·Status: COMPLETED
-
Trendelenburg Maneuver Versus Passive Leg Raising Test for Fluid Responsiveness in High-Risk Surgical Patients
NCT06423833 ·Status: COMPLETED ·Phase: NA
-
Impact of Fluid and Passive Leg Raising on Cardiac Output in Patients Undergoing Cardiac Surgery
NCT03179033 ·Status: COMPLETED
-
Corrected Flow Time in the Carotid Artery as a Predictor of Fluid Responsiveness in Mechanically Ventilated Patients With Low Tidal Volume in the Intensive Care Unit
NCT04139031 ·Status: COMPLETED
-
Prediction of Fluid Responsiveness in Atrial Fibrillation Patients Who Underwent Valvular Heart Surgery: Peep-induced Increase in Central Venous Pressure vs. Passive Leg Raising
NCT02224378 ·Status: COMPLETED ·Phase: NA
-
Clot Formation and Coagulation Factors Consumption in the Clearing Fluid After Arterial Catheter Blood Sampling.
NCT06349551 ·Status: COMPLETED
-
Peripheral Tissue Perfusion in Intensive Care
NCT06384287 ·Status: RECRUITING
-
Preload Dependence During Prone Position In ARDS Patients
NCT01965574 ·Status: COMPLETED ·Phase: NA
-
Metabolic Fluid Responsiveness in Children
NCT07255469 ·Status: RECRUITING
-
Detection of Hypovolemia in the Elderly Patient Undergoing Surgery
NCT06229938 ·Status: COMPLETED
-
Reliability of PVI Changes During Tidal Volume Challenge in ICU Patients
NCT05428423 ·Status: UNKNOWN
-
Passive Leg Raise Induced Stroke Volume Changes in Elderly Prior to Elective Surgery Measured by LiDCOplusTM
NCT02977390 ·Status: COMPLETED ·Phase: NA
-
Arterial Pressure Derived Dynamic Parameters to Detect Preload Responsiveness in Mechanically Ventilated Patients Under Spontaneous Mode
NCT06495489 ·Status: COMPLETED
-
Prone Positioning in ARDS: Predicting Neurological Complications Via Cerebral Hemodynamics
NCT06967285 ·Status: RECRUITING
-
Parameters of Cerebral Perfusion
NCT02806492 ·Status: COMPLETED ·Phase: NA
-
Laboratory Outcome Predictors in Coronary Surgery
NCT01178866 ·Status: COMPLETED
-
Mean Systemic Filling Pressure and Heart Performance Predicting Fluid Responsiveness
NCT02060942 ·Status: COMPLETED
-
Prevalence of Hypotension Associated With Preload Dependence During Continuous Renal Replacement Therapy
NCT03139123 ·Status: COMPLETED
-
Changes in Portal Vein Pulsatility Variability During a Tidal Volume Challenge Can Predict Fluid Tolerance
NCT07131228 ·Status: NOT_YET_RECRUITING
-
Pressure Gradient for Venous Return in Predicting Fluid Responsiveness in Patients Undergoing Laparoscopic Surgery
NCT04030221 ·Status: UNKNOWN
-
Predicting Hypotension During Dialysis in the ICU
NCT01171352 ·Status: WITHDRAWN
-
Dynamic Preload Indicators in Sitting Position
NCT02000570 ·Status: COMPLETED ·Phase: NA