Restoration of Leg Length, Offset, and Center of Rotation in Total Hip Replacement
NCT00738803 · Status: UNKNOWN · Phase: NA · Type: INTERVENTIONAL · Enrollment: 100
Last updated 2009-02-06
Summary
The investigators aim to demonstrate the ability to accurately measure and restore leg length, offset, and center of rotation during a total hip replacement through a new technique that uses the femoral component as a measurement tool. The operative technique requires inserting the femoral component prior to performing the femoral neck osteotomy. After the femoral component is implanted, a reference guide is attached to the femoral component and guides a screw into the ilium at a fixed distance from the femoral component. The pre-arthroplasty measurements of leg length and offset are recorded. The femoral neck osteotomy is performed, and the native femoral head is removed and measured. The acetabular socket is prepared and the acetabular component is inserted. A repeat measurement with trial modular neck components is taken and allows the surgeon an additional opportunity to accurately recreate leg length and offset with the final component. The reference screw is removed from the ilium and the incision is closed.
Conditions
Interventions
- PROCEDURE
-
Total hip replacement
Total hip replacement typically preformed for hip arthritis
Sponsors & Collaborators
-
Tennessee Orthopedic Alliance
lead OTHER
Principal Investigators
-
William B Kurtz, MD · Tennessee Orthopedic Alliance
Study Design
- Allocation
- NON_RANDOMIZED
- Purpose
- TREATMENT
- Masking
- NONE
- Model
- SINGLE_GROUP
Eligibility
- Min Age
- 18 Years
- Sex
- ALL
- Healthy Volunteers
- Yes
Timeline & Regulatory
- Start
- 2007-06-30
- Primary Completion
- 2009-04-30
- Completion
- 2010-04-30
Countries
- United States
Study Locations
More Related Trials
-
Safety of Non-delayed Weight Bearing After Total Hip Replacement With Non-Cemented Fiber Metal Taper Stem
NCT00179088 ·Status: COMPLETED ·Phase: NA
-
Subsidence of Short Stem THA With DORR Type C
NCT06768541 ·Status: COMPLETED
-
Cup Position in THA With Standard Instruments
NCT03189303 ·Status: COMPLETED
-
CT-based 3D Planning, Computer Navigation and Subsequent Migration Analysis in Total Hip Arthroplasty
NCT05159206 ·Status: COMPLETED ·Phase: NA
-
Total Hip Arthroplasty Using Small Direct Anterior Incision: The Role of Short Femoral Stem
NCT01614028 ·Status: UNKNOWN ·Phase: NA
-
Comparison Between Automated and Manual Component Impaction in Total Hip Arthroplasty
NCT05480813 ·Status: COMPLETED ·Phase: NA
-
Pillow Use During Total Hip Arthroplasty
NCT03825029 ·Status: UNKNOWN ·Phase: NA
-
Stability of Revision Total Hip Arthroplasty Implants Using Radiostereometric Analysis
NCT01668160 ·Status: WITHDRAWN ·Phase: NA
-
The Relationship Between Component Position and RoM
NCT02884349 ·Status: UNKNOWN ·Phase: NA
-
Comparison of Implant Positioning With Robotic Aided Surgery and Traditional Jig Positioning in Total Knee Arthroplasty
NCT03052790 ·Status: WITHDRAWN ·Phase: NA
-
Analysis of Defined Elements on DXA in Patients Undergoing Hip Arthroplasty
NCT06324708 ·Status: RECRUITING ·Phase: NA
-
A Randomized Study of Approaches in Total Hip Arthroplasty
NCT01613508 ·Status: COMPLETED ·Phase: NA
-
Measured vs Navigated Techniques in Total Hip Arthroplasty
NCT05393778 ·Status: UNKNOWN ·Phase: NA
-
Efficiency and Safety of Navigation Aids in Total Hip Arthroplasty With Direct Anterior Approach
NCT07134036 ·Status: COMPLETED ·Phase: NA
-
The Difference of Angle of Femoral Component Rotation in TKA With Gap Balance and Measured Resection Technique
NCT03358381 ·Status: UNKNOWN ·Phase: NA
-
Medial Wedge Insoles to Improve Gait in Persons After Total Hip Replacement
NCT05736016 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Comparison of Muscle Atrophy After Direct Anterior & Posterior Total Hip Arthroplasty
NCT01636375 ·Status: COMPLETED
-
Study of Surgical Technique With Use of Single-radius Prosthesis in Total Knee Replacement
NCT01505452 ·Status: COMPLETED
-
Legs Dysmetria in Total Hip Replacement: Does Hip Approacches and Navigation Decrease the Risk?
NCT06506201 ·Status: RECRUITING ·Phase: NA
-
Midvastus Versus Medial Parapatellar Approach for Minimally Invasive Total Knee Arthroplasty
NCT01132378 ·Status: COMPLETED ·Phase: NA
-
Study of Total Hip Arthroplasty Using Radlink Surgical Positioning Software
NCT02536573 ·Status: COMPLETED ·Phase: NA
-
Imaging of Joint Replacement Complications by PET/CT
NCT01970228 ·Status: COMPLETED ·Phase: NA
-
Safety and Effectiveness of the HIT Reverse HRS
NCT05357378 ·Status: RECRUITING ·Phase: NA
-
Variability in Spinopelvic Parameters Among Patients Undergoing Total Hip Arthroplasty
NCT05212090 ·Status: COMPLETED ·Phase: NA
-
Evaluation of Proprioception in Patients With Total Hip Replacement
NCT05763368 ·Status: WITHDRAWN ·Phase: NA