Effect of Water Exchange Method on Single-balloon Enteroscopy
NCT01942863 · Status: COMPLETED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 110
Last updated 2016-03-25
Summary
Enteroscopy, including double balloon enteroscopy (DBE), single balloon enteroscopy (SBE) and spiral enteroscopy (SE) currently, have shown good performances in small bowel diagnostics and seem to be useful in the clinical routine. However, enteroscopy is a time-consuming procedure. During common practice, large volumes of air need to be insufflated for good visualization. It leads to significant distention of the small bowel during the examination, which makes further intubation more technically challenging because of the formation of distended bowel loops and acute angulations and limits the maximal intubation length. According to the published data, the oral insertion depth of different kinds of enteroscopy is limited to approximately 240 cm. The total examination rate range form 18% to 86% for DBE and 0% to 11% for SBE.
It is thought that the intubation depth in small bowel determines the diagnostic yield and the following treatment. The deeper the enteroscopy is advanced into the small bowel, the more lesions may be found and treated. In order to improve the intubation depth of balloon enteroscopy, several methods, such as carbon dioxide insufflation and decompression side tube-equipped device, have been tried and showed positive effects. CO2 insufflation could also reduce severe pain during DBE and residual gas retention after the procedure because of rapid absorption. However, it is not known how much CO2 insufflation can decrease the distention of small bowel and the formation of bowel loops.
Recently, the use of water infusion in lieu of air insufflation has been shown to facilitate completion of colonoscopy, even in potentially difficult patients with prior abdominal or pelvic surgery. Water exchange method obviates excessive lengthening of the colon and the formation of acute angulation, which may cause less pain and easier intubation during scope insertion. Recently, water exchange method was also tried in two patients undergoing SBE via antegrade route in our center. Distal ileum 8cm near to ICV and the cecum was reached respectively (unpublished data), indicating water exchange be a useful method for deep intubation of SBE.
Here a prospective, randomized, controlled trial was designed to investigate whether, compared with CO2 insufflation method, water exchange method could increase the intubation depth and diagnostic yield in patients undergoing SBE.
Conditions
- Single Balloon Enteroscopy
Interventions
- PROCEDURE
-
water exchange single balloon enteroscopy
Oral enteroscopy was performed first, followed by the anal route on the same day or later. For oral route, SBE was first advanced beyond Treitz ligation with CO2 insufflation. Then the water exchange method was used for further insertion. Briefly, residual air in the lumen was suctioned, and 37°C water was infused with a peristaltic pump through the biopsy channel to obtain lumen visualization. Turbid luminal water due to residual feces was suctioned and replaced by clean water until the small bowel lumen was clearly visualized again. Thus, infused water was removed predominantly during the insertion phase. The total volume of water was not restricted. For anal route, water exchange or CO2 insufflation method was used from the beginning of insertion respectively.
- PROCEDURE
-
CO2 insufflation single balloon enteroscopy
Conventional enteroscopy was performed as CO2 insufflated during insertion. Oral enteroscopy was performed first, followed by the anal route on the same day or later.
- OTHER
-
Procedural Requirements
SBE was advanced as deeply as possible and complete small bowel visualization was attempted. When the following conditions were met, tattooing at the deepest position with India ink was performed and the endoscope was withdrawn: no further endoscopic advancement could be achieved, detection of a significant lesion and no other lesions suspected, severe stricture, obvious sedation and SBE-related adverse events happened which required termination of further intubation.
Sponsors & Collaborators
-
Air Force Military Medical University, China
lead OTHER
Principal Investigators
-
Shuhui Liang, M.D. · Associated professor
Study Design
- Allocation
- RANDOMIZED
- Purpose
- DIAGNOSTIC
- Masking
- DOUBLE
- Model
- PARALLEL
Eligibility
- Min Age
- 18 Years
- Max Age
- 80 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2013-12-31
- Primary Completion
- 2015-08-31
- Completion
- 2015-08-31
Countries
- China
Study Locations
More Related Trials
-
The Effect of Cap-assisted Water Exchange Colonoscopy on Straight Passage of the Colonoscope Through the Sigmoid Colon, Without Loop Formation
NCT06992856 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Comparing Maximal and Half-maximal Suction Pressure Applied During Water Exchange in Colonoscopy
NCT01948284 ·Status: UNKNOWN ·Phase: NA
-
Left-colon WEC May Reduce Insertion Time Compared With Whole-colon WEC.
NCT01735266 ·Status: COMPLETED ·Phase: NA
-
Water Injection Colonoscopy vs Air Insufflation Colonoscopy in Experienced Endoscopists
NCT01797406 ·Status: UNKNOWN ·Phase: NA
-
Investigation of Cecal Intubation Rates and Pain Levels Between Water Exchange and Air Insufflation Flexible Sigmoidoscopy
NCT03209349 ·Status: COMPLETED ·Phase: NA
-
Water Method in Low-body Mass Index (BMI) Female Patients With Unsedated Colonoscopy
NCT01546259 ·Status: WITHDRAWN ·Phase: NA
-
Comparing Cap-assisted Water Exchange and Water Exchange in Colonoscopy
NCT02759081 ·Status: COMPLETED ·Phase: NA
-
Water Injection Colonoscopy vs Air Insufflation Colonoscopy in Training the Beginners
NCT01762735 ·Status: UNKNOWN ·Phase: NA
-
Adenoma Detection Rate in Water and Air Colonoscopy Using Computer-aided System
NCT05448300 ·Status: UNKNOWN ·Phase: NA
-
Comparison Air Versus Carbon Dioxide Insufflation in Single Balloon Anterograde Enteroscopy
NCT03811522 ·Status: UNKNOWN
-
Water Method Colonoscopy in Patients With Prior Surgery
NCT01485133 ·Status: COMPLETED
-
Comparing the Adenoma Detection Rate With Air Insufflation, Water Immersion and Water Exchange
NCT01894191 ·Status: COMPLETED ·Phase: NA
-
Optimal Procedural Sequence in Same-day Bidirectional Endoscopy: A Prospective Randomized Controlled Study
NCT02708212 ·Status: COMPLETED ·Phase: NA
-
A Comparison of Air Insufflation, Water Immersion and Water Exchange Colonoscopy in Diagnostic Patients
NCT01781650 ·Status: COMPLETED ·Phase: NA
-
Impact of Reinforced Education by Wechat and Short Message Service on the Quality of Bowel Preparation
NCT02832869 ·Status: UNKNOWN ·Phase: PHASE4
-
Comparing Clinical Performance of Novice Trainee Endoscopists Using Conventional Air Insufflation Versus Warm Water Infusion Colonoscopy
NCT01482546 ·Status: COMPLETED
-
Dose the Saline Reduce the Mucus Production When Water Exchange Colonoscopy is Used?
NCT04769739 ·Status: COMPLETED ·Phase: NA
-
Comparing Water Exchange, Water Immersion and Air Insufflation Methods During Colonoscopy With the Option of on Demand Sedation
NCT01699399 ·Status: COMPLETED ·Phase: NA
-
"Air Assisted"Water Injection Colonoscopy in Experienced Endoscopists
NCT01797393 ·Status: UNKNOWN ·Phase: NA
-
Efficacy and Safety of Carbon Dioxide Insufflation During Endoscopy
NCT02502136 ·Status: COMPLETED ·Phase: NA
-
Comparisons of SWI, WWI and CI in Potentially Difficult Colonoscopy.
NCT03571061 ·Status: COMPLETED ·Phase: NA
-
The Best Dosage and Timing of Polyethylene Glycol for Bowel Preparation Before Capsule Endoscopy
NCT02486536 ·Status: COMPLETED ·Phase: PHASE4
-
Comparison of Procedural Sequences in Same-day Painless Bidirectional Endoscopy With Colonoscopic Water Exchange Method
NCT03638713 ·Status: COMPLETED ·Phase: NA
-
Effect of Carbon Dioxide Insufflation and Appendix on the Restoration of Intestinal Microecology After Colonoscopy.
NCT05637021 ·Status: UNKNOWN
-
Water Exchange and CO2 Insufflation with Abdominal Compression Device to Reduce Manual Assistance
NCT06496958 ·Status: RECRUITING ·Phase: NA