Optimal dRug Eluting steNts Implantation Guided By Intravascular Ultrasound and Optical coheRence tomoGraphy ORENBURG

NCT01917201 · Status: UNKNOWN · Phase: NA · Type: INTERVENTIONAL · Enrollment: 1000

Last updated 2014-10-28

No results posted yet for this study

Summary

The objective of this research is to assess the clinical results of implantation of different drug eluting stents under "aggressive" intravascular ultrasound (IVUS) guided all the way up to 24 months after operation and to establish the significance of the data of an optical coherent tomography (OCT) for the assessment of direct results of stenting and the degrees of endothelization of stent after 6 months.

The following hypothesis formed the base for this study:

* IVUS guided intervention allows to improve the results and increase the safety of implantation drug eluting stents.
* Suboptimal results according to IVUS data can influence the follow up results of treatment.
* Suboptimal results according to OCT data, which are not revealed by IVUS, can influence the follow up results of treatment.
* The use of strategy of stenting with the achievement of optimal results under the intravascular methods of visualization allows to reduce the time of application of antiplatelet therapy.
* The modern limus-eluting stents do not differ in the follow up results in investigated criteria.

Conditions

Interventions

PROCEDURE

IVUS-guided group

The randomization on groups was completed in accordance with stents to be implanted: "Xience Prime"/"Xience V", "Promus Element", "Resolute Integrity", "Biomatrix Flex", "Nobori", "Orsiro". In each group randomization on subgroups of IVUS-guided implantation and non-IVUS in the ratio 2:1 was completed. After randomization it is carried out coronary stenting under IVUS-control: a choice of length and diameter of stent - according to IVUS data. After the completion of implantation and postdilatation of stents the control IVUS is being used. If criteria of optimal implantation were not achieved, additional impact is being made: larger balloon, higher pressure, sufficient time of impact. In case of an additional impact the repeated control IVUS is being completed and the following results are being fixed. After control IVUS the OCT procedure is carried out. During OCT possible problems corresponding to stenting are being fixed. An additional impact based on OCT data is not being used.

PROCEDURE

Non-IVUS group

The randomization on groups was completed in accordance with stents to be implanted: "Xience Prime"/"Xience V", "Promus Element", "Resolute Integrity", "Biomatrix Flex", "Nobori", "Orsiro". In each group randomization on subgroups of IVUS-guided implantation and non-IVUS in the ratio 2:1 was completed. After randomization it is carried out coronary stenting under angiography control. After postdilatation control OCT is carried out. During OCT possible problems corresponding to stenting (malapposed struts, separate beams, a prolapse of fiber, microthrombosis) are being fixed. An additional impact based on OCT data is not being used.

Sponsors & Collaborators

  • The Orenburg Regional Clinical Hospital

    lead OTHER_GOV

Principal Investigators

  • Victor V Demin, MD, PhD · THE HEAD OF INTERVENTIONAL CARDIOLOGY AND ANGIOLOGY DEPARTMENT OF THE STATE BUDGETARY ESTABLISHMENT OF HEALTH "THE ORENBURG REGIONAL CLINICAL HOSPITAL"

Study Design

Allocation
RANDOMIZED
Purpose
TREATMENT
Masking
NONE
Model
PARALLEL

Eligibility

Min Age
18 Years
Max Age
75 Years
Sex
ALL
Healthy Volunteers
No

Timeline & Regulatory

Start
2012-03-31
Primary Completion
2014-12-31
Completion
2016-12-31

Countries

  • Russia

Study Locations

More Related Trials

Entities

Read the full study record

This page highlights key information. For complete eligibility criteria, study locations, investigator contacts, and the full protocol, visit the original record on ClinicalTrials.gov.

View NCT01917201 on ClinicalTrials.gov