Use of Transcollation Device to Decrease Blood Loss During Hepatic Resections: a Randomized Cohort Study (HEPACOLL)
NCT01874639 · Status: UNKNOWN · Phase: PHASE2 · Type: INTERVENTIONAL · Enrollment: 140
Last updated 2016-07-29
Summary
Blood loss in hepatic surgery is the main factor of postoperative morbidity. The use of the most effective possible tool for hemostasis allows a bleeding decrease during liver transection and thus could reduce postoperative morbidity.
In the past decade, the improvement of techniques of transection of the hepatic parenchyma was one of the most important factors to ensure the hepatectomy safety. But the clinical performances of these technological innovations (ultrasound dissectors, monopolar radiofrequency probes and dissection devices using pressurized water) remain still unclear.
The medical device of hemostasis Aquamantys® (Salient company, Innopath) use the technology of "transcollation" combining a source of radiofrequency associated with a conductive liquid (NaCl 0.9% solution). The system consists of a specific generator (Aquamantys Pump Generator®) and single-use probes (Aquamantys 2.3 BipolarSealer®). The energy of radiofrequency is delivered by two bipolar electrodes. The innovative aspect of this device consists in maintaining the tissue to a temperature of 100°C, while using a conductive liquid which acts as process of cooling and avoids the drying out of tissues, smoke, risks of electric arc and overheating met with conventional electrosurgery. This device allows the coagulation of blood vessels but also bile ducts. The Aquamantys® system could decrease the postoperative morbidity and mortality due to a decrease of blood loss and biliary leak. These clinical benefits could be translated by an improvement of the direct and indirect costs associated to the surgery. However the Aquamantys® technology has not been scientifically validated in the context of the hepatic surgery, and this technology is expensive due to the purchase of single-use bipolar probes (Aquamantys 2.3 BipolarSealer®) and to the investment in a generator (Aquamantys Pump Generator®).
Consequently, it is essential to realize a study measuring the clinical and medical economic impact of the transcollation technology (Aquamantys® device) in the hepatic surgery.
Conditions
- Hepatectomy
Interventions
- DEVICE
-
standard bipolar coagulation
- DEVICE
-
Aquamantys® probe for liver hemostasis
Sponsors & Collaborators
-
INNOPATH
collaborator UNKNOWN -
MEDTRONIC labs provide the aquamantys® probes for the study.
collaborator UNKNOWN -
University Hospital, Clermont-Ferrand
lead OTHER
Principal Investigators
-
Emmanuel BUC · University Hospital, Clermont-Ferrand
Study Design
- Allocation
- RANDOMIZED
- Purpose
- TREATMENT
- Masking
- SINGLE
- Model
- PARALLEL
Eligibility
- Min Age
- 18 Years
- Max Age
- 80 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2013-06-30
- Primary Completion
- 2016-12-31
- Completion
- 2016-12-31
Countries
- France
Study Locations
More Related Trials
-
Efficacy and Tolerability of Hemopatch After Hepatic Resection
NCT03323359 ·Status: UNKNOWN ·Phase: NA
-
Fibrinogen in Liver Transplant Subjects
NCT06764927 ·Status: WITHDRAWN ·Phase: PHASE4
-
Prevention of Post-Polypectomy Colorectal Bleeding by Clips in Patients on Anticoagulants
NCT07007598 ·Status: RECRUITING
-
Adjunctive Application of BioFoam Surgical Matrix in Liver Surgery
NCT01458561 ·Status: TERMINATED ·Phase: PHASE3
-
Tranexamic Acid Versus Placebo to Reduce Perioperative Bleeding After Major Hepatectomy
NCT00657384 ·Status: TERMINATED ·Phase: PHASE3
-
Correlation Between Reticulated Platelets and Major Adverse Cardiac and Cerebrovascular Events After Noncardiac Surgery
NCT02097602 ·Status: COMPLETED
-
Role of Topical Tranexamic Acid in Total Hip Arthroplasty
NCT01866943 ·Status: TERMINATED ·Phase: PHASE2
-
Thrombin Generation in Liver Transplant Surgery
NCT04762550 ·Status: UNKNOWN
-
Intraoperative Phlebotomies and Bleeding in Liver Transplantation
NCT04826666 ·Status: COMPLETED
-
Systematic Analysis of a Standardized Questionnaire to Detect Possible Bleeding Disorders and Its Impact on Perioperative Hemostasis Management
NCT04993170 ·Status: COMPLETED
-
Noninferiority Oral Tranexamic Acid vs Intravenous Administration in Total Hip Arthroplasty
NCT04691362 ·Status: COMPLETED ·Phase: PHASE4
-
Tranexamic Acid for Unilateral Total Knee Arthroplasty
NCT01594671 ·Status: COMPLETED ·Phase: PHASE3
-
Fibrinogen in Liver Transplant
NCT07265843 ·Status: NOT_YET_RECRUITING ·Phase: PHASE4
-
ClotFoam as an Adjunct to Hemostasis in Abdominal Surgery - Liver Bleeding is Encountered
NCT02264730 ·Status: UNKNOWN ·Phase: PHASE1
-
Tranexamic Acid Versus Placebo for Blood to Reduce Perioperative Bleeding Post-liver Resection
NCT01651182 ·Status: COMPLETED ·Phase: PHASE3
-
Viscoelastic Tests-Guided Therapy In Liver Transplantation
NCT03756948 ·Status: COMPLETED ·Phase: NA
-
Comparison of Blood Product Use and Bleeding Events During and After Endoscopic or Neurosurgical Procedures in Patients With Cirrhosis and Coagulopathy
NCT02457403 ·Status: COMPLETED ·Phase: NA
-
The Use of Tranexamic Acid to Reduce Blood Loss in Acetabular Surgery
NCT02684851 ·Status: COMPLETED ·Phase: PHASE3
-
Safety and Efficacy of Activated Recombinant Human Factor VII in Patients Undergoing Orthotopic Liver Transplantation
NCT01563458 ·Status: COMPLETED ·Phase: PHASE2
-
Prevention of Postoperative Bleeding in Subcapital Femoral Fractures
NCT02150720 ·Status: COMPLETED ·Phase: PHASE3
-
Personalized ViscoElastic Testing-guided Bleeding Management In Liver Surgery, Neurosurgery and Obstetrics
NCT06635564 ·Status: RECRUITING
-
Coagulopathy in Cardiac Surgery
NCT03475940 ·Status: COMPLETED
-
Clinical Safety and Performance of GATT-Patch in Open Liver Surgery
NCT04819945 ·Status: COMPLETED ·Phase: NA
-
Rapid Diagnostic of Hyperfibrinolysis in Liver Transplantation
NCT03012633 ·Status: COMPLETED
-
Topical Application of Tranexamic Acid Reduces Postoperative Blood Loss in Total Hip Arthroplasty
NCT01260818 ·Status: UNKNOWN ·Phase: NA