Use of Transcollation Device to Decrease Blood Loss During Hepatic Resections: a Randomized Cohort Study (HEPACOLL)

NCT01874639 · Status: UNKNOWN · Phase: PHASE2 · Type: INTERVENTIONAL · Enrollment: 140

Last updated 2016-07-29

No results posted yet for this study

Summary

Blood loss in hepatic surgery is the main factor of postoperative morbidity. The use of the most effective possible tool for hemostasis allows a bleeding decrease during liver transection and thus could reduce postoperative morbidity.

In the past decade, the improvement of techniques of transection of the hepatic parenchyma was one of the most important factors to ensure the hepatectomy safety. But the clinical performances of these technological innovations (ultrasound dissectors, monopolar radiofrequency probes and dissection devices using pressurized water) remain still unclear.

The medical device of hemostasis Aquamantys® (Salient company, Innopath) use the technology of "transcollation" combining a source of radiofrequency associated with a conductive liquid (NaCl 0.9% solution). The system consists of a specific generator (Aquamantys Pump Generator®) and single-use probes (Aquamantys 2.3 BipolarSealer®). The energy of radiofrequency is delivered by two bipolar electrodes. The innovative aspect of this device consists in maintaining the tissue to a temperature of 100°C, while using a conductive liquid which acts as process of cooling and avoids the drying out of tissues, smoke, risks of electric arc and overheating met with conventional electrosurgery. This device allows the coagulation of blood vessels but also bile ducts. The Aquamantys® system could decrease the postoperative morbidity and mortality due to a decrease of blood loss and biliary leak. These clinical benefits could be translated by an improvement of the direct and indirect costs associated to the surgery. However the Aquamantys® technology has not been scientifically validated in the context of the hepatic surgery, and this technology is expensive due to the purchase of single-use bipolar probes (Aquamantys 2.3 BipolarSealer®) and to the investment in a generator (Aquamantys Pump Generator®).

Consequently, it is essential to realize a study measuring the clinical and medical economic impact of the transcollation technology (Aquamantys® device) in the hepatic surgery.

Conditions

  • Hepatectomy

Interventions

DEVICE

standard bipolar coagulation

DEVICE

Aquamantys® probe for liver hemostasis

Sponsors & Collaborators

  • INNOPATH

    collaborator UNKNOWN
  • MEDTRONIC labs provide the aquamantys® probes for the study.

    collaborator UNKNOWN
  • University Hospital, Clermont-Ferrand

    lead OTHER

Principal Investigators

  • Emmanuel BUC · University Hospital, Clermont-Ferrand

Study Design

Allocation
RANDOMIZED
Purpose
TREATMENT
Masking
SINGLE
Model
PARALLEL

Eligibility

Min Age
18 Years
Max Age
80 Years
Sex
ALL
Healthy Volunteers
No

Timeline & Regulatory

Start
2013-06-30
Primary Completion
2016-12-31
Completion
2016-12-31

Countries

  • France

Study Locations

More Related Trials

Read the full study record

This page highlights key information. For complete eligibility criteria, study locations, investigator contacts, and the full protocol, visit the original record on ClinicalTrials.gov.

View NCT01874639 on ClinicalTrials.gov