Feasibility Study Using Zone-MPC Controller, HMS and Technosphere® Insulin Inhalation System From MannnKind Corp
NCT01874392 · Status: COMPLETED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 9
Last updated 2021-11-11
Summary
This clinical trial is a feasibility study to assess the performance of an Artificial Pancreas (AP) device using the Artificial Pancreas System (APS©) platform for subjects with type 1 diabetes using rapid-acting insulin as well as preprandial inhaled insulin (Technosphere® Insulin Inhalation System by MannKind Corporation). The goal of this proposed study is to explore the feasibility of using multiple insulin delivery routes in order to mimic the physiology of both first- and second-phase insulin secretion. The intent is to exploit the rapid action achieved by inhaled insulin to compensate for part of the meals and utilize the conventional subcutaneous route for management of basal insulin and as second-phase meal-related insulin.
Conditions
- Type 1 Diabetes Mellitus
Interventions
- DRUG
-
Investigational inhaled insulin (Technosphere)
by MannKind Corp. IND 61,729
- DEVICE
-
Artificial Pancreas (AP) device (APS©)
Device includes: * OneTouch® Ping® Glucose Management System with modified Meter-Remote from Animas® Corp or the OmniPod® Insulin Management System from Insulet Corp. * Dexcom® G4® CGM System (CGM) from Dexcom® Corp * Control algorithm: zone-Model Predictive Control (zone-MPC) with safety Health Monitoring System (HMS)
Sponsors & Collaborators
-
Juvenile Diabetes Research Foundation
collaborator OTHER -
Sansum Diabetes Research Institute
lead OTHER
Principal Investigators
-
Howard Zisser, MD · Sansum Diabetes Research Institute
Study Design
- Allocation
- NA
- Purpose
- TREATMENT
- Masking
- NONE
- Model
- SINGLE_GROUP
Eligibility
- Min Age
- 21 Years
- Max Age
- 65 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2012-10-31
- Primary Completion
- 2013-06-30
- Completion
- 2013-06-30
Countries
- United States
Study Locations
More Related Trials
-
Safety and Feasibility Evaluation of the APS APP
NCT03504046 ·Status: COMPLETED ·Phase: PHASE2/PHASE3
-
OpT2mise Glucose Control in Type 2 Diabetes Mellitus (DM) With Insulin Pump Therapy
NCT01182493 ·Status: COMPLETED ·Phase: NA
-
Artificial Pancreas Control System in an Outpatient Setting
NCT01871870 ·Status: COMPLETED ·Phase: PHASE2
-
Use of the Paradigm 722 System to Improve Glycemic Control in Adult and Adolescent Subjects With Type 1 Diabetes
NCT00211510 ·Status: COMPLETED ·Phase: NA
-
Feasibility Evaluation of an Artificial Pancreas With Glucose Prediction Trust Index
NCT03092310 ·Status: COMPLETED ·Phase: NA
-
A Study to Evaluate a Multiple Model Probabilistic Predictive Controller (MMPPC) for Closed Loop Insulin Delivery
NCT01492062 ·Status: WITHDRAWN ·Phase: NA
-
A Multicenter Study of Outpatient Automated Blood Glucose Control With a Bihormonal Bionic Pancreas
NCT02092220 ·Status: COMPLETED ·Phase: NA
-
Automated Insulin Delivery in Pregnant Patients With Type 1 Diabetes With Extension Into Outpatient at Home
NCT04492566 ·Status: COMPLETED ·Phase: NA
-
Artificial Pancreas Control System in an Inpatient Setting
NCT01552603 ·Status: COMPLETED ·Phase: PHASE2
-
Effect of Inhaled Technosphere Insulin vs RAA Insulin on Exercise-Induced Hypoglycemia in Adults With T1D Using Automated Insulin Delivery
NCT06880835 ·Status: RECRUITING ·Phase: NA
-
Model Predictive Control (MPC) Artificial Pancreas vs. Sensor Augmented Pump (SAP)/Predictive Low Glucose Suspend (PLGS) With Different Food Choices in the Outpatient Setting
NCT03767790 ·Status: COMPLETED ·Phase: NA
-
Feasibility Study for Training Pump Naïve Subjects To Use The Paradigm® System And Evaluate Effectiveness
NCT00530023 ·Status: COMPLETED ·Phase: PHASE4
-
Exercise-Induced Hypoglycemia Prevention in Adults With Type 1 Diabetes Using an Artificial Pancreas
NCT03859401 ·Status: COMPLETED ·Phase: NA
-
Cross-over Study to Evaluate the Safety and Efficacy of Night Closed-loop Control Using the MD-Logic Automated Insulin Delivery System Compared to Sensor Augmented Pump Therapy in Poorly Controlled Patients With Type 1 Diabetes
NCT02733211 ·Status: WITHDRAWN ·Phase: NA
-
Dual-hormone Artificial Pancreas Versus Single-hormone Under Exercise and a Meal Challenge
NCT06082973 ·Status: COMPLETED ·Phase: NA
-
Safety and Efficacy of Artificial Pancreas With and Without a Meal Detection Module on Glycemic Control in Adolescents With Type 1 Diabetes After a Missed Bolus
NCT02909829 ·Status: COMPLETED ·Phase: NA
-
Glycemic Outcomes and Safety With Minimed 780G System in Children With Type 1 Diabetes Aged 2-6 Years
NCT04949022 ·Status: UNKNOWN ·Phase: NA
-
Reduction of Nocturnal Hypoglycemia and Hyperglycemia in the Home Using Predictive Algorithms, Pump Suspension, and Insulin Dosing in Children and Young Adolescents
NCT02714972 ·Status: COMPLETED ·Phase: PHASE2
-
A Study of Glucose Control in Participants With Type 1 and Type 2 Diabetes
NCT04667182 ·Status: WITHDRAWN
-
Inpatient Evaluation of the MD-Logic Artificial Pancreas System in Patients With Type 1 Diabetes
NCT01501032 ·Status: WITHDRAWN ·Phase: PHASE1
-
Use of an Automated Insulin Delivery System Compared to Sensor Augmented Pump at Patients With Type 1 Diabetes (T1D)
NCT02636491 ·Status: COMPLETED ·Phase: NA
-
Closed-loop Control of Glucose Levels (Artificial Pancreas) for 5 Days in Adults With Type 1 Diabetes
NCT02488616 ·Status: WITHDRAWN ·Phase: PHASE2
-
Insulet Artificial Pancreas Early Feasibility Study
NCT02897557 ·Status: COMPLETED ·Phase: NA
-
Comparison of the Effect on the Glucose Infusion Rates Between Inhaled Technosphere Insulin and a Subcutaneous Injection of Regular Human Insulin
NCT00511979 ·Status: COMPLETED ·Phase: PHASE1
-
Multi-center Trial in Adult and Pediatric Patients With Type 1 Diabetes Using Hybrid Closed Loop System and Control at Home
NCT02748018 ·Status: COMPLETED ·Phase: NA