Artificial Pancreas Control System in an Inpatient Setting
NCT01552603 · Status: COMPLETED · Phase: PHASE2 · Type: INTERVENTIONAL · Enrollment: 14
Last updated 2016-06-03
Summary
The purpose of this study is to verify an automated system of blood glucose control in Type I Diabetics. The automated system consists of the investigational Artificial Pancreas Control software (APC), two blood glucose sensors, and two hormone pumps, one for delivering insulin to lower blood sugar, and the second for delivering glucagon to raise blood sugar. The blood glucose sensors relays information to the Artificial Pancreas software, which uses the Adaptive Proportional Device algorithm to determine the rate of insulin and glucagon infusion by the hormone pumps. In prior studies, the Adaptive Proportional Device algorithm has been verified, but required manual input into the computer and hormone pumps. This study differs in that it uses a fully automated system under the control of the Artificial Pancreas Control software. The importance of this change is that it is the next step to enable outpatient use of automated, closed loop blood glucose control.
Conditions
- Type I Diabetes Mellitus
Interventions
- DEVICE
-
Artificial Pancreas Control Software
This master controller software is used in conjunction with two subcutaneous continuous glucose monitoring systems and two Omnipod pumps, one for administering aspart insulin (NovoLog) and one for administering glucagon (GlucaGen), to control blood glucose levels. The insulin and glucagon infusion rates are determined by an automated version of the Adaptive Proportional Derivative (APD) insulin and glucagon control algorithm.
Sponsors & Collaborators
-
Juvenile Diabetes Research Foundation
collaborator OTHER -
Legacy Health System
lead OTHER
Principal Investigators
-
W K Ward, MD · Legacy Health Research
Study Design
- Allocation
- NA
- Purpose
- TREATMENT
- Masking
- NONE
- Model
- SINGLE_GROUP
Eligibility
- Min Age
- 21 Years
- Max Age
- 65 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2012-03-31
- Primary Completion
- 2013-08-31
- Completion
- 2013-09-30
Countries
- United States
Study Locations
More Related Trials
-
Sensor-Augmented Insulin Delivery: Insulin Plus Glucagon Versus Insulin Alone
NCT00797823 ·Status: COMPLETED ·Phase: PHASE2
-
Individualizing Automated Closed Loop Glucose Control Through Pharmacokinetic Profiling in an Insulin-Only Bionic Pancreas
NCT03262116 ·Status: TERMINATED ·Phase: PHASE2/PHASE3
-
Closed-Loop Glucagon Administration For Hypoglycemia Treatment
NCT02181127 ·Status: COMPLETED ·Phase: NA
-
An Outpatient Study of Automated Blood Glucose Control With an Insulin-Only Bionic Pancreas
NCT02536950 ·Status: COMPLETED ·Phase: NA
-
Closed Loop Context Aware AID
NCT06676657 ·Status: RECRUITING ·Phase: NA
-
Feasibility Evaluation of an Artificial Pancreas With Glucose Prediction Trust Index
NCT03092310 ·Status: COMPLETED ·Phase: NA
-
Dual-hormone Artificial Pancreas Versus Single-hormone Under Exercise and a Meal Challenge
NCT06082973 ·Status: COMPLETED ·Phase: NA
-
Artificial Pancreas With Different Stress Assessments in the Outpatient Setting
NCT04142229 ·Status: COMPLETED ·Phase: NA
-
The Summer Camp Study 2: Blood Glucose Control With a Bi-Hormonal Endocrine Pancreas
NCT02105324 ·Status: COMPLETED ·Phase: NA
-
Real-time Adaptation to Changes in Insulin Sensitivity
NCT01261052 ·Status: COMPLETED ·Phase: PHASE2
-
Outpatient Automated Blood Glucose Control With a Bi-hormonal Bionic Endocrine Pancreas
NCT01762059 ·Status: COMPLETED ·Phase: NA
-
Four Way Crossover Closed Loop With Exercise Detection
NCT02862730 ·Status: COMPLETED ·Phase: NA
-
The Monitoring Study
NCT02969863 ·Status: COMPLETED ·Phase: NA
-
The Insulin-Only Bionic Pancreas Bridging Study
NCT03565666 ·Status: COMPLETED ·Phase: PHASE2/PHASE3
-
Insulet Artificial Pancreas Early Feasibility Study
NCT02897557 ·Status: COMPLETED ·Phase: NA
-
The Set-Point Study: Evaluating Effects of Changing Glucose Target on Bionic Pancreas Performance
NCT02509065 ·Status: COMPLETED ·Phase: NA
-
Portable Artificial Pancreas Applied for Youth and Adolescents
NCT05543850 ·Status: COMPLETED ·Phase: NA
-
The Use of Mini-dose Glucagon to Prevent Exercise-induced Hypoglycemia in Type 1 Diabetes
NCT02660242 ·Status: COMPLETED ·Phase: PHASE2
-
Using an Artificial Pancreas System in Older Adult Type 1 Diabetes Mellitus Patients
NCT03353792 ·Status: TERMINATED ·Phase: NA
-
Outpatient Control-to-Range: System and Monitoring Testing
NCT01697150 ·Status: COMPLETED ·Phase: NA
-
Closed-loop Control of Glucose Levels (Artificial Pancreas) for 5 Days in Adults With Type 1 Diabetes
NCT02488616 ·Status: WITHDRAWN ·Phase: PHASE2
-
A Study to Evaluate a Multiple Model Probabilistic Predictive Controller (MMPPC) for Closed Loop Insulin Delivery
NCT01492062 ·Status: WITHDRAWN ·Phase: NA
-
Closed-loop Control of Overnight Glucose Levels (Artificial Pancreas) in Type 1 Diabètes Adults With Hypoglycemia Unawareness and Documented Nocturnal Hypoglycemia
NCT02282254 ·Status: COMPLETED ·Phase: PHASE2
-
Reduction of Nocturnal Hypoglycemia and Hyperglycemia in the Home Using Predictive Algorithms, Pump Suspension, and Insulin Dosing in Children and Young Adolescents
NCT02714972 ·Status: COMPLETED ·Phase: PHASE2
-
Crossover Feasibility Study of Portable AP Device With Zone-MPC and HMS and Adapted I:C and Basal Insulin
NCT01929798 ·Status: COMPLETED ·Phase: EARLY_PHASE1