Artificial Pancreas Control System in an Outpatient Setting
NCT01871870 · Status: COMPLETED · Phase: PHASE2 · Type: INTERVENTIONAL · Enrollment: 20
Last updated 2015-05-15
Summary
The objectives of this outpatient research study are (1) to assess the ability of this automated system to be operated by a subject with limited professional oversight; (2) to assess whether the new devices (Dexcom Gen 4 sensors, Motorola ES400 smart phone, iDex pump controller) will reduce the frequency of hardware and data communication lapses seen in the previous system; and (3) to measure the degree of glucose control achievable with this automated system. The system will adjust blood glucose by administering insulin and glucagon. Insulin is a hormone that lowers blood glucose and will be given nearly continuously during this study. Glucagon raises blood glucose and will be automatically administered during hypoglycemia. Both are natural hormones made by people without diabetes. Each subject will have four devices placed on his abdomen: two Omnipod insulin pumps, one for delivering insulin and one for delivering glucagon, and two Dexcom G4 glucose sensors for measuring glucose. The two sensors will feed glucose data into Motorola smart phone master controller, which will calculate the correct amount of insulin or glucagon to deliver. The system will then send the command to the correct Omnipod through the iDex pod controller.
In this new system, the research subject will be able to monitor the progress of the study by use of the smart phone graphical user interface. The subject will have a companion with him/her during the entire study for safety purposes. Both the subject and companion will complete a training course on how to treat diabetic emergencies and how to operate the system. A study physician and technician will be in the hotel during each study and will be monitoring the study via a cloud-based data communication system. These studies will be carried out in a hotel setting.
Conditions
- Type 1 Diabetes Mellitus
Interventions
- DEVICE
-
Artificial Pancreas Control Software
This master controller software is used in conjunction with two subcutaneous continuous glucose monitoring systems and two Omnipod pumps, one for administering aspart insulin (NovoLog) and one for administering glucagon (GlucaGen), to control blood glucose levels. The insulin and glucagon infusion rates are determined by an outpatient automated version of the Adaptive Proportional Derivative (APD) insulin and glucagon control algorithm programmed into a smart phone.
Sponsors & Collaborators
-
Juvenile Diabetes Research Foundation
collaborator OTHER -
Legacy Health System
lead OTHER
Principal Investigators
-
William K Ward, MD · Legacy Health
Study Design
- Allocation
- NA
- Purpose
- TREATMENT
- Masking
- NONE
- Model
- SINGLE_GROUP
Eligibility
- Min Age
- 21 Years
- Max Age
- 60 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2013-05-31
- Primary Completion
- 2013-09-30
- Completion
- 2013-10-31
Countries
- United States
Study Locations
More Related Trials
-
Outpatient Control-to-Range: System and Monitoring Testing
NCT01697150 ·Status: COMPLETED ·Phase: NA
-
Integration of Continuous Glucose Monitoring Into a BiHormonal Closed-Loop Artificial Pancreas
NCT01161862 ·Status: COMPLETED ·Phase: NA
-
Feasibility Study Assessing The Ability Of An Insulin Pump-Controlling Algorithm To Minimize Hypoglycemia And Hyperglycemia In Patients With Type 1 Diabetes In A Clinical Research Setting
NCT01401751 ·Status: COMPLETED ·Phase: NA
-
Dual-hormone Artificial Pancreas Versus Single-hormone Under Exercise and a Meal Challenge
NCT06082973 ·Status: COMPLETED ·Phase: NA
-
A Multicenter Study of Outpatient Automated Blood Glucose Control With a Bihormonal Bionic Pancreas
NCT02092220 ·Status: COMPLETED ·Phase: NA
-
Safety and Efficacy of Artificial Pancreas With and Without a Meal Detection Module on Glycemic Control in Adolescents With Type 1 Diabetes After a Missed Bolus
NCT02909829 ·Status: COMPLETED ·Phase: NA
-
Closed-Loop Glucagon Administration For Hypoglycemia Treatment
NCT02181127 ·Status: COMPLETED ·Phase: NA
-
Effect of HCL Insulin Delivery System on Glycemic Control in Patients With T1D
NCT05924932 ·Status: RECRUITING
-
Artificial Pancreas With Different Stress Assessments in the Outpatient Setting
NCT04142229 ·Status: COMPLETED ·Phase: NA
-
Feasibility Study Using Zone-MPC Controller, HMS and Technosphere® Insulin Inhalation System From MannnKind Corp
NCT01874392 ·Status: COMPLETED ·Phase: NA
-
Four Way Crossover Closed Loop With Exercise Detection
NCT02862730 ·Status: COMPLETED ·Phase: NA
-
Reduction of Nocturnal Hypoglycemia and Hyperglycemia in the Home Using Predictive Algorithms, Pump Suspension, and Insulin Dosing in Children and Young Adolescents
NCT02714972 ·Status: COMPLETED ·Phase: PHASE2
-
Evaluation of Physician-based Decision Support
NCT03443713 ·Status: COMPLETED ·Phase: NA
-
Closed-loop Control of Glucose Levels (Artificial Pancreas) for 5 Days in Adults With Type 1 Diabetes
NCT02488616 ·Status: WITHDRAWN ·Phase: PHASE2
-
CGM Use in Poorly Controlled Youth With Type 1 Diabetes
NCT04721145 ·Status: COMPLETED ·Phase: NA
-
Closed-loop Control of Glucose Levels (Artificial Pancreas) for 24 Hours in Adults and Adolescents With Type 1 Diabetes
NCT01754337 ·Status: COMPLETED ·Phase: PHASE2
-
Two Way Crossover Closed Loop Study MPC vs FMPD
NCT04771403 ·Status: COMPLETED ·Phase: NA
-
Outpatient Automated Blood Glucose Control With a Bi-hormonal Bionic Endocrine Pancreas
NCT01762059 ·Status: COMPLETED ·Phase: NA
-
Feasibility Evaluation of an Artificial Pancreas With Glucose Prediction Trust Index
NCT03092310 ·Status: COMPLETED ·Phase: NA
-
Fault Detection, Zone MPC and DiAs System in T1D
NCT02773875 ·Status: UNKNOWN ·Phase: NA
-
Feasibility Study of a Portable Artificial Pancreas System in Type 1 Diabetes Mellitus (T1DM) - Montpellier
NCT01447979 ·Status: COMPLETED ·Phase: EARLY_PHASE1
-
Sensor-Augmented Insulin Delivery: Insulin Plus Glucagon Versus Insulin Alone
NCT00797823 ·Status: COMPLETED ·Phase: PHASE2
-
Closed Loop Context Aware AID
NCT06676657 ·Status: RECRUITING ·Phase: NA
-
Closed-loop Control of Overnight Glucose Levels (Artificial Pancreas) in Type 1 Diabètes Adults With Hypoglycemia Unawareness and Documented Nocturnal Hypoglycemia
NCT02282254 ·Status: COMPLETED ·Phase: PHASE2
-
Closed-loop Glucose Control for Automated Management of Type 1 Diabetes
NCT00811317 ·Status: COMPLETED ·Phase: NA