SmartCare Driven Pressure Support-Non Invasive Ventilation Feasibility Study
NCT01870089 · Status: TERMINATED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 11
Last updated 2017-05-08
Summary
Knowledge-based systems were initially developped to automatically adapt pressure support settings during invasive ventilation, and proved to be at least as efficient as experienced clinicians.
Non-invasive ventilation has become the standard of care for patients suffering from acute hypercapnic respiratory failure (ARF)and has reduced the need for endotracheal intubation in these patients, thus reducing their hospital mortality.
NIV success or failure is closely related to the tolerance of NIV treatment, which is tightly correlated to patient-ventilator synchrony. As severe asynchronies frequently occurs during NIV (namely in more than 40% of patients) and as the occurence of asynchronies is related to the use of high pressure support levels, to the presence of leaks and/or to non optimal expiratory trigger settings, very frequent ventilator settings adaptations should allow reducing patient-ventilator asynchronies but require the presence of an experienced clinician at the bedside during NIV treatment.
A computer-driven ventilator settings adaptation has the adavantage of permitting very frequent ventilator settings adaptation whithout requiring the presence of an experienced clinician at the bedside and could possibly improve patient-ventilator interaction.
The aim of the present study is to test the faisability of using the Smartcare NIV computer-driven system to automatically adapt ventilator settings during non invasive ventilation delivered because of acute respiratory failure.
Conditions
- Acute Respiratory Failure
Interventions
- DEVICE
-
SmartCare/PS-NIV Drägerwerk Lübeck Germany
Sponsors & Collaborators
-
University of Lausanne Hospitals
lead OTHER
Principal Investigators
-
Philippe Jolliet, Prof · University of Lausanne Hospitals
Study Design
- Allocation
- NA
- Purpose
- TREATMENT
- Masking
- NONE
- Model
- SINGLE_GROUP
Eligibility
- Min Age
- 18 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2013-05-31
- Primary Completion
- 2016-08-31
- Completion
- 2016-08-31
Countries
- Switzerland
Study Locations
More Related Trials
-
Non-Invasive Ventilation Versus Continuous Positive Airway Pressure in Cardiogenic Pulmonary Edema: a Multicentre Study
NCT00785174 ·Status: COMPLETED ·Phase: PHASE3
-
Sonographic Evaluation of Diaphragmatic Function Under Nasal High-flow (NHF) and Non-invasive Ventilation (NIV) in Respiratory Insufficiency
NCT07050147 ·Status: COMPLETED ·Phase: NA
-
Monitoring of Patients With Chronic Respiratory Failure Treated With Non-invasive Home Ventilation: Contribution of New Monitoring Tools
NCT04872062 ·Status: UNKNOWN
-
Unloading Respiratory Muscles During NIV: Comparison of a Spontaneous and Auto-adjusting Controlled Mode
NCT00366912 ·Status: TERMINATED ·Phase: NA
-
Evaluation of Prolonged Apnea Supported by High Frequency Non-invasive Ventilation.
NCT02712190 ·Status: UNKNOWN ·Phase: NA
-
Noninvasive Ventilation After Extubation in Hypercapnic Patients
NCT01047852 ·Status: COMPLETED ·Phase: NA
-
Improving Non-invasive Ventilation
NCT01571986 ·Status: RECRUITING
-
Neural Pressure Support for Low Pulmonary Compliance
NCT05566652 ·Status: UNKNOWN ·Phase: NA
-
Therapy Study of Automated Protocolized vs. Physician-Directed Non-Protocolized Weaning
NCT00606788 ·Status: SUSPENDED ·Phase: NA
-
Non-invasive Ventilation in Severe Chronic Obstructive Pulmonary Disease(COPD)
NCT00710541 ·Status: TERMINATED ·Phase: NA
-
Automatic Control of Pressure Support Ventilation in Surgical Intensive Care Units
NCT00445289 ·Status: COMPLETED ·Phase: NA
-
Patient-ventilator Interactions in Long Term Non-invasive Ventilation: Influence of Back-up Frequency
NCT01130090 ·Status: COMPLETED ·Phase: NA
-
Evaluation of Conventional Non-invasive Mechanical Ventilation (NIV) Versus an Automatic Ventilation Mode.
NCT03872167 ·Status: COMPLETED ·Phase: NA
-
Impact of Dyspnea, Regional Lung Ventilation, and Diaphragmatic Function During de Novo Acute Respiratory Failure
NCT04961437 ·Status: COMPLETED
-
NIV Versus HFO for Acute Exacerbations of Interstitial Lung Diseases
NCT06182956 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Ventilation Strategies During Spontaneous Breathing Trial
NCT02939963 ·Status: COMPLETED ·Phase: NA
-
Volume-targeted Versus Pressure-limited Noninvasive Ventilation in Patients With Acute Hypercapnic Respiratory Failure
NCT02538263 ·Status: COMPLETED ·Phase: NA
-
Prevalence of an Early Success of Non-invasive Ventilation in the Emergency Departement.
NCT06213623 ·Status: NOT_YET_RECRUITING
-
Influence of an Inverse Pressure Ramp in Long-term Non-invasive Ventilation on Dyspnea in the Morning After Therapy
NCT04093427 ·Status: TERMINATED ·Phase: NA
-
Early Non-invasive Ventilation Outside the Intensive Care Unit
NCT01572337 ·Status: COMPLETED ·Phase: PHASE4
-
Out-of-Hospital Non-Invasive Ventilation for Patients With Acute Respiratory Failure
NCT00885898 ·Status: COMPLETED ·Phase: NA
-
BEACON Care ® System Assisting Ventilation in Pressure Support Ventilation (PSV) Patient
NCT02760147 ·Status: COMPLETED ·Phase: NA
-
Autotitrating Versus Standard Non-invasive Ventilation (NIV) in Acute Exacerbation of Respiratory Failure
NCT01174316 ·Status: WITHDRAWN ·Phase: NA
-
Comparison of Humidification Devices During Non Invasive Ventilation, in Acute Respiratory Failure
NCT00190346 ·Status: TERMINATED ·Phase: NA
-
Volume Mode Non-invasive Ventilation in Amyotrophic Lateral Sclerosis
NCT05328492 ·Status: UNKNOWN ·Phase: NA