Comparison of Optic Nerve Sheath Diameter on Retrobulbar Ultrasound Before and After Drainage of Cerebrospinal Fluid in Patient With Hydrocephalus
NCT01863329 · Status: TERMINATED · Type: OBSERVATIONAL · Enrollment: 15
Last updated 2019-03-27
Summary
Studies in patients with intracranial hypertension have shown a good relationship between optic nerve sheath diameter measured by retrobulbar ultrasound and invasively measured intracranial pressure. The aim of this study was to evaluate changes in optic nerve sheath diameter before and after drainage of cerebrospinal fluid in patients with hydrocephalus.
Conditions
- Hydrocephalus
Interventions
- PROCEDURE
-
retrobulbar ultrasound
both optic nerve sheath diameter (the posterior 3mm of the papilla), 5 individual measurement
Sponsors & Collaborators
-
Yonsei University
lead OTHER
Eligibility
- Min Age
- 20 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2013-03-31
- Primary Completion
- 2013-03-31
- Completion
- 2013-09-30
Countries
- South Korea
Study Locations
More Related Trials
-
The Effect of Pneumoperitoneum on Intracranial Pressure in Pediatric Laparoscopic Surgery: Ultrasonographic Measurement of Optic Nerve Sheath Diameter
NCT01840267 ·Status: COMPLETED
-
Optic Nerve Sheath Diameter (ONSD) With the Raised PCO2 and Internal Jugular Venous Occlusion
NCT02361658 ·Status: COMPLETED
-
Sonography of the Optic Nerve Sheath Diameter for Detection of Elevated Intracranial Pressure (ICP)
NCT03529370 ·Status: COMPLETED
-
Optic Nerve Sheath Diameter as a Screening Test for Increased Intracranial Pressure
NCT02338284 ·Status: UNKNOWN
-
Optic Nerve Sheath Diameters in Idiopathic Intracranial Hypertension Patients
NCT04603118 ·Status: COMPLETED ·Phase: NA
-
Non-invasive Intracranial Pressure Monitoring in Brain Tumor Patients
NCT07286396 ·Status: NOT_YET_RECRUITING
-
Diagnosis of Intracranial Hypertension Using TCCD, ONSD and ODH by Bedside Ultrasound
NCT07151287 ·Status: NOT_YET_RECRUITING
-
Intracranial Hypertension and Optic Nerve Sheath Diameter
NCT01796015 ·Status: COMPLETED ·Phase: NA
-
Ultrasonography of Optic Nerve Sheath Diameter for Noninvasive Detection of Raised Intracranial Pressure: ORIENT Study
NCT04981548 ·Status: UNKNOWN
-
Sonographic Monitoring of Weaning of Cerebrospinal Fluid Drainages
NCT02408757 ·Status: TERMINATED
-
Non-invasive ONSD-based Neuromonitoring in a Neurointensive Care Setting
NCT05818371 ·Status: UNKNOWN ·Phase: NA
-
The Effects of Lateral 45° Downward Position on the Optic Nerve Sheath Diameter
NCT05185908 ·Status: COMPLETED
-
Comparison of Pupilometer and Ultrasound of Optic Nerve Sheath Diameter in Estimating Intracranial Pressure (ICP)
NCT03115450 ·Status: COMPLETED
-
Measurement of the Optic Nerve Diameter in Different Healthcare Operators
NCT06830460 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Optic Nerve Sheath Diameter and Intracranial Pressure (ICP) in Children
NCT02507063 ·Status: WITHDRAWN
-
The Effect of Epidural Analgesia on Intracranial Pressure by Measuring the Optic Nerve Sheath Diameter Using Ultrasound in Pediatric Patients With Cerebral Palsy
NCT03200951 ·Status: COMPLETED ·Phase: NA
-
Automated Measurement of Optic Nerve Sheath Diameter
NCT02786706 ·Status: COMPLETED
-
The Effect of End-tidal Carbon Dioxide Level on the Optic Nerve Sheath Diameter in Pediatric Patients
NCT03988868 ·Status: COMPLETED
-
Changes in Optic Nerve Sheath Diameter in Response to Various Levels of End Tidal Carbon Dioxide Levels
NCT02711774 ·Status: COMPLETED
-
The Morphology and Parameter Estimation of Cranial Ultrasound Spectrum Based on Cerebral Artery
NCT04730713 ·Status: UNKNOWN
-
Identification of Corticomedullary Differentiation Along Different Stage of Pregnancy
NCT02193516 ·Status: UNKNOWN
-
Determination of Normal Measures of Optic Nerve Sheath Diameter in Children
NCT03178760 ·Status: COMPLETED
-
Effect of Head Rotation on Overlap and Relative Position of Internal Jugular Vein to Carotid Artery in Infants and Children: A Study of the Anatomy Using Ultrasonography
NCT01017328 ·Status: COMPLETED
-
The Prediction of Intracranial Pressure and Clinical Outcome by Transcranial Doppler in Neurocritical Patients
NCT00886054 ·Status: UNKNOWN
-
Assessment of Intracranial Pressure Using Optic Nerve Sheath Diameter in Head Trauma in Assiut University
NCT06726681 ·Status: NOT_YET_RECRUITING