MIRACLE EF Clinical Study

NCT01735916 · Status: TERMINATED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 44

Last updated 2017-11-06

Study results available
· View outcomes & findings →

Summary

This study is looking at whether the electrical treatment provided by a special type of pacemaker called a Cardiac Resynchronization Therapy (CRT) pacemaker may keep a patient's heart failure from getting worse. When the lower heart chambers (i.e. ventricles) are electrically paced to beat together by the CRT pacemaker, blood may be pumped to the body more efficiently.

The CRT pacemaker being studied in this clinical trial is approved by the US Food and Drug Administration (FDA) for patients with moderate to severe heart failure, whose hearts pump blood inefficiently. In the MIRACLE EF study, patients who have heart failure with slightly less inefficient hearts will be observed to see if the electrical pacing treatment is better than not getting the treatment. This study is being conducted to support FDA approval of this type of pacemaker for people whose heart failure is less inefficient.

Conditions

  • Congestive Heart Failure
  • Left Bundle Branch Block
  • Systolic Heart Failure

Interventions

DEVICE

CRT-P Implant

The Medtronic Consulta CRT-P (models C3TR01, C4TR011) dual chamber implantable pacemaker with cardiac resynchronization therapy (CRT-P) is a multi-programmable cardiac device that monitors and regulates the patient's heart rate by providing single or dual chamber rate-responsive bradycardia pacing, and sequential biventricular pacing. The device senses the electrical activity of the patient's heart using the electrodes of the implanted atrial and right ventricular leads. It then analyzes the heart rhythm based on selectable detection parameters. The device responds to bradyarrhythmias by providing bradycardia pacing therapy. Simultaneous or sequential biventricular pacing is used to provide patients with cardiac resynchronization therapy. The device also provides diagnostic and monitoring information that assists with system evaluation and patient care.

DEVICE

CRT-P OFF

Device programmed to minimal pacing at 40 beats/minute. Device and arrhythmia diagnostics may remain enabled.

Sponsors & Collaborators

  • Medtronic Cardiac Rhythm and Heart Failure

    lead INDUSTRY

Principal Investigators

  • Cecilia Linde, MD PhD · Karolinska University Hospital

Study Design

Allocation
RANDOMIZED
Purpose
TREATMENT
Masking
QUADRUPLE
Model
PARALLEL

Eligibility

Min Age
18 Years
Sex
ALL
Healthy Volunteers
No

Timeline & Regulatory

Start
2012-12-31
Primary Completion
2014-03-31
Completion
2014-03-31

Countries

  • United States
  • India
  • Russia
  • Sweden
  • United Kingdom

Study Locations

More Related Trials

Read the full study record

This page highlights key information. For complete eligibility criteria, study locations, investigator contacts, and the full protocol, visit the original record on ClinicalTrials.gov.

View NCT01735916 on ClinicalTrials.gov