Performance Comparison of Revaclear With Larger Dialyzer
NCT01722695 · Status: COMPLETED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 30
Last updated 2025-03-13
Summary
The purpose of the study is to show equivalent performance of the Revaclear dialyzer when compared to a dialyzer with larger membrane surface area.
Study design: open, randomized, cross-over, multicentric, controlled prospective
Medical devices: Revaclear 200 versus FX 60 or Revaclear 400 versus FX 100, depending on patient needs
Patients/sample size: 30 adult chronic hemodialysis patients
Treatment: Each patient will be treated by hemodialysis for one week (3 dialysis sessions) with Revaclear dialyzers and one week (3 dialysis sessions) with FX dialyzers.
Objectives: intraindividual comparison of dialysis dose; reduction rates and total removal of urea, phosphate, creatinine and ß2-microglobulin; albumin loss
Primary variable: dialysis dose Kt/V urea
Secondary variable: reduction rates and total removal of urea, phosphate, creatinine and ß2-microglobulin
Safety variable: albumin loss, blood count
Conditions
- Renal Failure Chronic Requiring Hemodialysis
Interventions
- OTHER
-
Dialyzer comparison
Each patient is treated by hemodialysis for one week (3 sessions) with each dialyzer type (Revaclear or FX). The order of dialyzers used will be randomly assigned to the patient at randomization.
Sponsors & Collaborators
-
Gambro Dialysatoren GmbH
collaborator INDUSTRY -
Baxter Healthcare Corporation
collaborator INDUSTRY -
Vantive Health LLC
lead INDUSTRY
Principal Investigators
-
Alexander Rosenkranz, Prof. · Medical University Graz, Austria
Study Design
- Allocation
- RANDOMIZED
- Purpose
- TREATMENT
- Masking
- NONE
- Model
- CROSSOVER
Eligibility
- Min Age
- 18 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2012-11-30
- Primary Completion
- 2012-12-31
- Completion
- 2012-12-31
Countries
- Austria
Study Locations
More Related Trials
-
Blood Compatibility Characteristics of Baxter Xenium+, Fresenius FX and Gambro Polyflux Dialyzers
NCT01273870 ·Status: COMPLETED
-
Comparative Effects Of Dialysate Flow Rate And Membrane Packing On The Performance Of Dialyzers Used For Hemodialysis
NCT00636077 ·Status: COMPLETED ·Phase: NA
-
A Pilot Study of a Heparin Dosing Algorithm for Hemodialysis
NCT01181544 ·Status: COMPLETED ·Phase: NA
-
Investigation of Performance and Compatibility of the Baxter Dialyzer Xenium XPH 210 During On-line Hemodiafiltration
NCT00976846 ·Status: COMPLETED ·Phase: NA
-
Gambro AK200 ULTRA Hemodiafiltration Study
NCT01202708 ·Status: COMPLETED ·Phase: NA
-
Dialysis Performance of the FX CorAL Membrane
NCT06203795 ·Status: COMPLETED ·Phase: NA
-
Theranova Randomized, Controlled, Trial (RCT) in China
NCT05309291 ·Status: COMPLETED ·Phase: NA
-
Reduction of Heparin Dose in Dialysis With Evodial System
NCT00781690 ·Status: COMPLETED ·Phase: NA
-
Efficacy of Uremic Toxins Clearance With Expanded Hemodialysis
NCT04786535 ·Status: UNKNOWN ·Phase: NA
-
Comparative Clinical Performance of Dialyzers Applied During High Volume Online Haemodiafiltration
NCT04102280 ·Status: COMPLETED ·Phase: NA
-
Exploratory Study to Explore the Safety and Efficacy of the HDx Therapy Using Theranova 500 Dialyzer in Comparison to Hemodiafiltration
NCT03499691 ·Status: COMPLETED ·Phase: NA
-
Effect of Increased Convective Clearance by On-Line Hemodiafiltration on All Cause Mortality in Chronic Hemodialysis Patients
NCT00205556 ·Status: COMPLETED ·Phase: NA
-
Second Clinical Evaluation of THERANOVA-500 Dialyzer in Chronic Hemodialysis (HD)
NCT03618368 ·Status: UNKNOWN ·Phase: NA
-
Effect of Expanded Dialysis on Patient Reported Symptoms Using LEVIL
NCT03640858 ·Status: COMPLETED ·Phase: NA
-
Determination In-vivo KUF for Diacap Pro Hemodialyser
NCT02964429 ·Status: COMPLETED ·Phase: NA
-
Comparison of Hemodialysis With Medium Cut-off Dialyzer (Theranova) and High Flux Dialyzer
NCT03211676 ·Status: COMPLETED ·Phase: NA
-
Comparison FX CorDiax 60 in Relation to the FX 60-Dialyzer
NCT01534741 ·Status: COMPLETED ·Phase: PHASE4
-
Cardiovascular Risk Comparison Between Expanded Hemodialysis Using Theranova and On-line Hemodiafiltration
NCT03448887 ·Status: COMPLETED ·Phase: NA
-
Integrated Patient Care Intradialysis Programme in Hemodialysis Through a Virtual Health Platform
NCT04823286 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Effect of Dialysis Dose and Membrane Flux in Maintenance Hemodialysis
NCT00004285 ·Status: COMPLETED ·Phase: NA
-
Continuous Venovenous Hemofiltration Versus Continuous Venovenuous Hemodialysis
NCT01062984 ·Status: COMPLETED ·Phase: NA
-
A Clinical Trial of IntensiVE Dialysis
NCT00649298 ·Status: COMPLETED ·Phase: PHASE4
-
Evaluation of Biocompatibility and Performances of 4 Dialyzers in Different Mode Treatments
NCT03262272 ·Status: COMPLETED ·Phase: NA
-
Clearum High Flux Hemodialyzer Used in Hemodialysis for Subjects With End-Stage Renal Disease
NCT04395131 ·Status: COMPLETED ·Phase: NA
-
Dialysis Catheter Comparative Clinical Trial
NCT00526123 ·Status: COMPLETED ·Phase: NA