Technical Evaluation Of JewelPUMP In Type 1 Diabetic Patients Treated With Extern Insulin Pump
NCT01640210 · Status: COMPLETED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 28
Last updated 2012-07-13
Summary
The main objective of the study is to verify the reliability of the solutes volumes issued by the Debiotech JewelPUMPTM controlled by its remote.
Three clinical sites are participating in this study:
* CHSF, Service of Endocrinology and Diabetology, CORBEIL-ESSONNES (91): Dr. Guillaume CHARPENTIER, Dr. Sylvia FRANC
* Grenoble University Hospital, Department of Endocrinology, Diabetes Diseases, Nutrition, GRENOBLE (38): Pr Pierre-Yves BENHAMOU
* CHU Jean Minjoz, Department of Endocrinology and Diabetology, BESANCON (25): Professor Alfred PENFORNIS, Dr. Annie CLERGEOT
The study will be conducted in 20 patients with type 1 diabetes treated by external insulin pump. Patients will be informed of the study during a screening visit. After signing the informed consent, they will return to the center where they will wear a JewelPUMPTM containing saline water, they will use their pumps in parallel. The investigator or nurse education will form the operation of the JewelPUMPTM and they will be instructed to replicate the same settings between their usual and JewelPUMPTM pump. The patient will be asked to complete visual analog scales of satisfaction with their usual treatment and the various elements of the devices (usual pump, and JewelPUMPTM) have been weighed using a precision balance to have a form of a base for comparison.
Patients will leave home for a period of about three days, but they will have to come back every days to the center. They will be asked to collect all events arising (programming problems to deliver a bolus, hardware failure ...) in a booklet.
At the end of study visit, patients will return to the center where the volumes will be assessed by the perfused weighed the various components and devices where they will complete the visual analog scales of satisfaction at endpoint.
Conditions
- Type1diabetes
Interventions
- DEVICE
-
JewelPUMP (insulin patch pump)
The study will be proposed during the visit of selection. Visit of inclusion: This visit will take place after having received the consent of the patient. Women will be asked to achieve a pregnancy test. Patients will wear a JewelPUMP containing saline solution in parallel with their usual insulin pump. They will be trained to use JewelPUMP. Patients treated with insulin pump will be instructed to reproduce the same "programming" between their usual pump and the JewelPUMP, they will use in parallel. Volume infused will be evaluated during a period of basal and bolus with a precision scale. Patient monitoring: Patient have to come back to the centre every 24 hours for 3 days. Study visit: Patients will be asked to fill out a questionnaire of satisfaction to the JewelPUMPTM and Visual scales. Volume infused will be evaluated with a precision scale, by comparison of weight of JewelPUMP and patients' usual pump
Sponsors & Collaborators
-
Centre d'Etudes et de Recherche pour l'Intensification du Traitement du Diabète
lead OTHER
Principal Investigators
-
Guillaume Charpentier, MD · CHSF
Study Design
- Allocation
- NA
- Purpose
- TREATMENT
- Masking
- NONE
- Model
- SINGLE_GROUP
Eligibility
- Min Age
- 18 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2011-11-30
- Primary Completion
- 2012-03-31
- Completion
- 2012-03-31
Countries
- France
Study Locations
More Related Trials
-
Web-Based Follow-Up Using Cellular Phone in Type 1 Diabetic Patients Under Insulin Pump Therapy : The PumpNet Study
NCT00324584 ·Status: COMPLETED ·Phase: PHASE3
-
Smartguard Use in Real Life : a Longitudinal Study in Patients With Type 1 Diabetes
NCT03047486 ·Status: COMPLETED
-
Study of Insulin Pump in Prevention of Low Glucose Events in Adults With Type 1 Diabetes at Risk of Severe Hypoglycemia
NCT02657213 ·Status: COMPLETED ·Phase: NA
-
The Impact of Hybrid Closed-loop Insulin Delivery in Type 1 Diabetes on Glycemic Control and PROMs
NCT04414280 ·Status: ACTIVE_NOT_RECRUITING
-
Study the Feasibility of Permanent Use of inControl for the Treatment of Type 1 Diabetes
NCT02892604 ·Status: TERMINATED ·Phase: NA
-
Impact of the Mylife CamAPS FX System With the DEXCOM G6 Sensor on T1D Patients in France
NCT07048795 ·Status: RECRUITING
-
Efficacy of Automated Insulin Therapy Early Initiated After Diagnosis on Blood Glucose Control in Children and Adolescents With Type 1 Diabetes
NCT06283797 ·Status: RECRUITING ·Phase: NA
-
The MiniMed™ 780G Glycemic Control and Quality of Life Study for the Treatment of Pediatric and Adult Subjects With Type 1 Diabetes in France.
NCT04308291 ·Status: COMPLETED
-
Root Cause Determination of Catheter Obstructions
NCT03230266 ·Status: TERMINATED ·Phase: NA
-
Safety and Efficacy of 7-day Wear Infusion Set vs. Control Infusion Set.
NCT04208282 ·Status: COMPLETED ·Phase: NA
-
Closed-loop Control of Glucose Levels in the Context of Exercise in Adults With Type-1 Diabetes
NCT01297946 ·Status: COMPLETED ·Phase: PHASE1/PHASE2
-
Feasibility of Automated Insulin Delivery With an Interoperable Algorithm Using an Alternative Insulin Pump
NCT05299177 ·Status: TERMINATED ·Phase: NA
-
A Pilot Study to Assess the Feasibility of a Novel Non-invasive Technology to Measure Changing Blood Glucose Levels in Adults with Type-1 Diabetes Mellitus
NCT06097689 ·Status: COMPLETED ·Phase: NA
-
Real-life Follow-up of the Physical Activity in Type 1 Diabetes Participants Equipped With an Insulin Pump With Hybrid Closed Loop
NCT07015970 ·Status: COMPLETED
-
Real-life Data From Diabetic Patients on Closed-loop Pumps
NCT05418699 ·Status: COMPLETED
-
A Trial to Compare Automated Lyumjev Delivery With Carbohydrate Counting, Qualitative Meal-size Estimation, and Meal Detection in Type 1 Diabetes
NCT06021158 ·Status: RECRUITING ·Phase: PHASE2
-
Observational Study of the Use of DBLG1 System in Real Life
NCT04749693 ·Status: RECRUITING
-
Study of Insulin Pump Discontinuation in Adults With Diabetes
NCT04915066 ·Status: COMPLETED
-
Study of MiniMed™ 640G Insulin Pump With SmartGuard™ in Prevention of Low Glucose Events in Adults With Type 1 Diabetes
NCT02733991 ·Status: COMPLETED ·Phase: NA
-
Telemedicine Program in Type 1 Diabetes and CSII
NCT02790645 ·Status: COMPLETED ·Phase: NA
-
Telemedicine for Patients With an Hybrid Closed Loop System
NCT04900636 ·Status: COMPLETED ·Phase: NA
-
Cohort Study to Refine the Positioning of Closed-loop Therapy Versus Islet Transplantation in the Management of Patients With Unstable Type 1 Diabetes
NCT07006272 ·Status: RECRUITING
-
Obtain a Good Blood Glucose Control With the Paradigm Real Time System
NCT00441129 ·Status: COMPLETED ·Phase: NA
-
Dexcom Hybrid Closed Loop Insulin Pump Study in Type 1 Diabetes
NCT05059860 ·Status: COMPLETED
-
Diabeloop WP6.2 : Crossover Evaluation of Glycemic Control
NCT02627911 ·Status: COMPLETED ·Phase: PHASE2