Safety of Noninvasive Electrical Stimulation of Acupuncture Points (NESAP) in Infants

NCT01495286 · Status: COMPLETED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 30

Last updated 2012-11-19

Study results available
· View outcomes & findings →

Summary

This research study represents a pilot, open arm study that will evaluate the safety of using Non-invasive Electrical Stimulation of Acupuncture Points (NESAP) in 42 newborn infants less than 3 days of age who require heel sticks for clinical blood sampling. The investigators plan to enroll 51 infants into the study in order to obtain 42 completed infants. Two sub studies will precede the main safety study, with 6 infants in each sub study and 30 infants in the main study. These two sub studies will use electrical stimulation intensities that are a fraction of the planned intensity of electrical stimulation that will be used during the main part of the study.

The clinical trial will be performed at the University of Arkansas for Medical Sciences Hospital (Little Rock, AR). The study will evaluate the pain response to heel stick routinely used to obtain This blood from 30 term neonatal infants, ages 37 to 42 weeks Electrical stimulation will be applied at appropriate acupuncture points using a very low current for 10 minutes, routine for procedural pain. The response to pain will be assessed using pain scales and physiologic changes.

The investigators hypothesize that the NESAP procedure is safe in newborn infants undergoing a routine heelstick.

Conditions

Interventions

DEVICE

EMPI Select Transcutaneous Electrical Nerve Stimulation

Experimental: EMPI Select TENS unit For analgesia, StimCare electrodes will be placed on the baby's legs at specific acupuncture points and electrical stimulation will be administered via a standard EMPI Select TENS unit. For the main study, a low continuous current will be provided with voltage of 3.5 mA. The frequency will be delivered using a stimulation of 10 Hz for 10±1 minutes prior to the heelstick, with continued stimulation during and for 5±1 min after the heel stick. Two sub studies will precede the main safety study, with 6 infants in each, using electrical stimulation intensities that are a fraction of the planned intensity. Infants in sub study 1 will receive electrical stimulation at 1 mA and 2 Hz. Infants in sub study 2 will receive electrical stimulation at 2 mA and 10 Hz.

Sponsors & Collaborators

Principal Investigators

  • Richard Hall, MD · University of Arkansas

Study Design

Allocation
NA
Purpose
TREATMENT
Masking
NONE
Model
SINGLE_GROUP

Eligibility

Min Age
1 Day
Max Age
3 Days
Sex
ALL
Healthy Volunteers
No

Timeline & Regulatory

Start
2011-12-31
Primary Completion
2012-07-31
Completion
2012-07-31

Countries

  • United States

Study Locations

More Related Trials

Entities

Diseases

Read the full study record

This page highlights key information. For complete eligibility criteria, study locations, investigator contacts, and the full protocol, visit the original record on ClinicalTrials.gov.

View NCT01495286 on ClinicalTrials.gov