The Response Patterns to the Electrical Stimulation of Epidural Catheters With Varying Pulse Widths in Term Pregnant Women
NCT02762149 · Status: TERMINATED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 20
Last updated 2017-08-01
Summary
Epidural analgesia is commonly used for labor pain relief due to its safety and effectiveness. Despite a very high success rate, the epidural technique remains a somewhat blind technique and failures continue to occur. Unfortunately, there are no imaging techniques that can be used at the bedside to determine the proper positioning of the epidural catheter. The trans-catheter electric stimulation test (TCEST) has been successfully used for this purpose. This test is occasionally performed in situations where the immediate confirmation of the proper epidural catheter location is deemed necessary. The test helps to predict which epidurals might fail so that appropriate measures could be immediately implemented.
There has been one duration of electrical stimulus (0.2 milliseconds) that has been used in the majority of studies and in clinical practice. With this duration of stimulation, the vast majority of cases show a unilateral motor response of the lower limbs during the TCEST. Studies on the stimulation of peripheral nerves (nerves in the arms and legs) have shown that an electrical stimulus with a longer duration is able to stimulate nerves which are farther away. Since nerves in the epidural space are similar in composition to peripheral nerves, the investigators expect to see a higher rate of bilateral response with the longer duration of stimulus. The investigators also hope to show that this bilateral response is predictive of a better functioning epidural.
The investigators hypothesize that the incidence of a bilateral response to the TCEST will be higher with the 1.0 ms pulse width compared to 0.1 ms pulse width. Furthermore, the investigators hypothesize that a bilateral motor response associated with the 1.0 ms pulse width will be predictive of symmetry of sensory and motor block and of lower consumption of local anesthetic.
Conditions
- Labor Pain
Interventions
- DEVICE
-
Nerve stimulator
The nerve stimulator (Stimpod NMS 450: Xavant technology (PTY) Ltd; Pretoria, South Africa or similar nerve stimulator) will be connected to the epidural catheter through an adapter (Johans ECG Adapter, Arrow International Inc., Reading). The epidural catheter and the adapter will be primed with a standard volume of 3 ml of sterile normal saline to allow for effective electrical conduction. Secured connections and avoidance of any air within in the system must be ensured to avoid high impedance in the circuit, which could result in false negatives. The cathode terminal of the stimulator will then be attached to the metal hub of the adapter and the anode terminal will be connected to the electrode placed over the deltoid muscle.
Sponsors & Collaborators
-
Samuel Lunenfeld Research Institute, Mount Sinai Hospital
lead OTHER
Principal Investigators
-
Jose Carvalho, MD · MOUNT SINAI HOSPITAL
Study Design
- Allocation
- RANDOMIZED
- Purpose
- TREATMENT
- Masking
- DOUBLE
- Model
- PARALLEL
Eligibility
- Min Age
- 16 Years
- Max Age
- 55 Years
- Sex
- FEMALE
- Healthy Volunteers
- Yes
Timeline & Regulatory
- Start
- 2016-05-31
- Primary Completion
- 2016-08-31
- Completion
- 2016-08-31
Countries
- Canada
Study Locations
More Related Trials
-
Assessment of the Use of Ultrasound for Epidural Catheter Placement and Comparison With Palpation Technique
NCT02271100 ·Status: COMPLETED ·Phase: NA
-
Differential Sensory Block During Labor Epidural Analgesia: a Prospective Observational Study to Investigate the Relationship of Lower and Upper Sensory Block Levels to Cold With Sensory Block to Pinprick and Light Touch
NCT05187962 ·Status: COMPLETED
-
Identification of the Sensory Level Block to Cold During Epidural Analgesia for Labor: A Cohort Study to Determine the Influence of the Direction of Testing
NCT03572439 ·Status: COMPLETED ·Phase: NA
-
Loss of Resistance, w/wo Stimulation, For Epidural Placement
NCT03087604 ·Status: COMPLETED ·Phase: PHASE4
-
Epidural Catheter Thread Between Two Different Vendors
NCT03722446 ·Status: COMPLETED ·Phase: NA
-
Utilizing Ultrasound for Residents as an Aid in Epidural Placement
NCT03378492 ·Status: WITHDRAWN ·Phase: NA
-
Effectiveness Analysis of Ultrasound-guided Intratissue Percutaneous Electrolysis (EPI) in Patient With Chronic Low Back Pain
NCT04290221 ·Status: COMPLETED ·Phase: NA
-
Acupuncture With Manual and Electrical Stimulation to Reduce Labour Pain
NCT01197950 ·Status: COMPLETED ·Phase: NA
-
Epidural Wave Form Analysis vs Fluoroscopic Guidance for Thoracic Epidural Placement
NCT07217457 ·Status: ENROLLING_BY_INVITATION ·Phase: NA
-
Three-Dimensional Ultrasound (3D US) in Parturients
NCT01523249 ·Status: COMPLETED
-
Ultrasound-Guided Technique for Thoracic Epidural Insertion
NCT01449214 ·Status: COMPLETED ·Phase: NA
-
Electrical Epidural Stimulation Test for Detecting Epidural Catheter Reactivation in Obstetric Population
NCT04983511 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Pain Relief by Applying TENS on Acupuncture Points During the First Stage of Labour
NCT00148577 ·Status: UNKNOWN
-
Analgesic Efficacy of Transcutaneous Electrical Nerve Stimulation (TENS) Versus Placebo During the First Stage of Labor
NCT03990441 ·Status: UNKNOWN ·Phase: NA
-
Assessment of Sensory Block During Labour Epidural Analgesia in Patients Experiencing Pain During First Stage of Labour.
NCT05881395 ·Status: COMPLETED
-
fMRI Measurements on Pain Relief Methods in First Stage Labor Pain
NCT00768014 ·Status: UNKNOWN
-
The Efficacy of Acu-TENS as an Adjunct Analgesic During USG-MVA
NCT06411054 ·Status: RECRUITING ·Phase: NA
-
TENS for Suction Evacuation for Termination of 1st Trimester Pregnancies
NCT03494842 ·Status: UNKNOWN ·Phase: NA
-
Echo-guided Percutaneous Electrical Nerve Stimulation of the Femoral Nerve
NCT06894537 ·Status: COMPLETED ·Phase: NA
-
The Effect of Sacral Surface Electrical Stimulation for Assisted Reproductive Technology
NCT01082913 ·Status: UNKNOWN ·Phase: PHASE1/PHASE2
-
Tsui Test as a Predictor of Bupivacaine Consumption in Labour Epidurals
NCT00792311 ·Status: COMPLETED ·Phase: NA
-
Treatment of Acute Low Back Pain With Transcutaneous Electrical Neurostimulation at the Emergency Department: a Randomized Controlled Trial
NCT07183176 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Evaluation of the Effectiveness of Transcutaneous Electrical Nerve Stimulation During Labor.
NCT03137251 ·Status: COMPLETED ·Phase: NA
-
Gravity Flow Technique to Validate Proper Location of Epidural Needle Tip
NCT03317626 ·Status: COMPLETED ·Phase: NA
-
Nerve Conduction Block Using Transcutaneous Electrical Currents
NCT03169049 ·Status: UNKNOWN ·Phase: NA