Optimal Head Rotation and External Landmark for Internal Jugular Vein Cannulation After Placement of Proseal Laryngeal Mask Airway
NCT01407302 · Status: COMPLETED · Type: OBSERVATIONAL · Enrollment: 100
Last updated 2013-12-25
Summary
Recently, laryngeal mask airway (LMA) placements are frequently performed for general anesthesia. The investigators occasionally encounter a clinical situation to perform internal jugular vein (IJV) cannulation after LMA insertion, especially for difficult airway in subjects undergoing major surgery. However, anatomic relations of IJV and common carotid artery (CCA) in patient with LMA placement have been reported to be different from those in patients with endotracheal tube. The degree of overlapping of the right IJV and CCA after LMA placement was greater than before LMA placement. Furthermore, there are many cases of complete overlapping right IJV and CCA after LMA placement. Therefore, the risk of puncturing CCA increases when the investigators try to cannulate IJV after LMA placement. Furthermore, the central landmark commonly used for IJV cannulation was proved to show low success rate after LMA placement in previous report.
The investigators carefully examined the anatomic relations of IJV and CCA after LMA insertion with ultrasonography, and found that the degree of overlapping is different according to the degree of head rotation. The investigators postulated that if the degree of overlapping is different according to the degree of head rotation after LMA insertion, the investigators can find the angle of head rotation for least overlapping and reduce the risk of CCA puncture. Therefore, the investigators tried (1) to find the optimal head rotation angle appropriate for puncturing IJV after LMA placement, and (2) to find suitable landmark adequate for IJV cannulation after LMA placement.
Conditions
- General Anesthesia With Laryngeal Mask Airway (LMA)
Interventions
- OTHER
-
Head rotation
Repeated ultrasonographic examination according to the degree of head rotation (examination of overlap index of internal jugular vein and common carotid artery, and accuracy of external landmark of jugular cannulation)
Sponsors & Collaborators
-
Samsung Medical Center
lead OTHER
Principal Investigators
-
Mi Sook Gwak, M.D.,Ph.D. · Samsung Medical Center
Eligibility
- Min Age
- 20 Years
- Max Age
- 70 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2011-07-31
- Primary Completion
- 2012-12-31
- Completion
- 2012-12-31
Countries
- South Korea
Study Locations
More Related Trials
-
Comparison of Two Insertion Techniques of Proseal Laryngeal Mask Airway by Unskilled Personnel in Children
NCT01191619 ·Status: UNKNOWN ·Phase: NA
-
Double-lumen Tube Intubation Technique to Reduce Laryngeal Injuries
NCT01441362 ·Status: COMPLETED ·Phase: NA
-
C-MAC Videolaryngoscope Intubation and Cervical Spine Motion
NCT03567902 ·Status: UNKNOWN ·Phase: NA
-
Laryngoscope Asssited Lightwand Intubation
NCT01950702 ·Status: UNKNOWN ·Phase: NA
-
Neuromuscular Block in Laryngeal Mask Airway(LMA) Insertion
NCT01035021 ·Status: COMPLETED ·Phase: NA
-
The Insertion of I-gel and Classic LMA in Different Head Positions in Elderly Patients
NCT07027293 ·Status: RECRUITING ·Phase: NA
-
Clinical Acceptability of I-GEL® in Pediatric Patients: Comparison of Clinical Performance With Classic-LMA™
NCT01320163 ·Status: COMPLETED ·Phase: NA
-
Head and Neck Positions for Endotracheal Intubation Using a Videolaryngoscope
NCT05128968 ·Status: COMPLETED ·Phase: NA
-
Laryngeal Mask Airway (LMA) Insertion With Sevoflurane and Remifentanil
NCT01456299 ·Status: COMPLETED ·Phase: NA
-
The Clinical Efficacy of Supraglottic Airway Device, Self-pressurized Air-Q Intubating Laryngeal Airway (ILA -SP) in Adult Patients: Comparison With Classic-laryngeal Airway (c-LMA)
NCT02206438 ·Status: COMPLETED ·Phase: NA
-
The Comparison of the Clinical Efficacy Between I-gel and LMA-Supreme, the Two Most Recently Developed Supraglottic Airway Devices, in Elderly Patients
NCT02026791 ·Status: COMPLETED ·Phase: NA
-
The Comparison of Airway Sealing With the Laryngeal Mask Airway (LMA) Supreme at Different Intracuff Pressure in Children
NCT01738854 ·Status: COMPLETED ·Phase: NA
-
Intubation Success Rate_Rigid Video Stylet Vs Video Laryngoscope
NCT02769221 ·Status: UNKNOWN ·Phase: NA
-
Endobronchial Intubation of Double-lumen Tube: Conventional Method vs Fiberoptic Bronchoscope Guide Method
NCT03368599 ·Status: COMPLETED ·Phase: NA
-
Comparison of LMA Proseal and LMA Supreme for Efficient Ventilation During Lateral Positioned Laparoscopic Surgeres
NCT02852135 ·Status: COMPLETED ·Phase: NA
-
Cervical Spine Motion During Tracheal Intubation: Video Laryngoscope vs Rigid Video Stylet
NCT03120546 ·Status: COMPLETED ·Phase: NA
-
Laryngeal Mask Use in Knee-chest Position in Lumbar Surgery in Neurosurgical Patients
NCT02162368 ·Status: COMPLETED
-
Comparison of Efficiency Between I-gel Blind Intubation and I-gel Bronchoscopic Intubation During Resuscitation
NCT02411422 ·Status: COMPLETED ·Phase: NA
-
The Effect of Placement of Proseal Laryngeal Mask Airway With C-Mac Videolaryngoscopy
NCT03852589 ·Status: COMPLETED ·Phase: NA
-
Laryngeal Tube vs Laryngeal Mask Airway
NCT02607644 ·Status: COMPLETED ·Phase: NA
-
Videoscope Guided Flexible LMA Insertion
NCT03510299 ·Status: COMPLETED ·Phase: NA
-
Head Position for Endotracheal Intubation
NCT02418741 ·Status: COMPLETED ·Phase: NA
-
Cuff Pressure in LMS
NCT03929848 ·Status: UNKNOWN
-
Supreme LMA and Endotracheal Intubation Use in Caesarean Section
NCT01858467 ·Status: COMPLETED ·Phase: NA
-
Optimal Intubating Technique Using Videolaryngoscopy in Patients With Semi-rigid Neck Collar
NCT04578119 ·Status: COMPLETED ·Phase: NA