The Efficacy of i-Scan for Detecting Reflux Esophagitis

NCT01381991 · Status: COMPLETED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 500

Last updated 2011-06-27

No results posted yet for this study

Summary

Endoscopy is a widely used modality for the diagnosis and classification of Gastroesophageal reflux disease (GERD), and the extent of esophageal mucosal breaks on endoscopy can be assessed. However, there were some limitation in diagnosis of GERD using endoscopy

1. More than half of patients with GERD reveal no visible abnormality on conventional endoscopy, it is possible that minute mucosal changes are underestimated by conventional endoscopy due to the limitation of visual ability
2. In addition of uncertainty in detecting mucosal breaks, uncertainty in describing severity of mucosal injury can lead to inconsistency among interpreters. Interobserver agreement regarding diagnosis and classification of GERD using endoscopy is unsatisfactory to apply daily practice.

Thus, the development of a new method to define the intra-esophageal injury for use in daily practice is a worthwhile endeavor and developed, such as narrow-band imaging (NBI), Fuji Intelligent Chromoen-doscopy (FICE) and i-scan.

Among them, i-scan technology is the most recently developed image enhancing technology, which consists of three modes of image enhancement, i.e. surface enhancement (SE), contrast enhancement (CE), and tone enhancement (TE).

Thus, the investigators examined the hypothesis that i-scan can improve the detection rate of reflux esophagitis and inter-observer agreement between endoscopists compared with conventional white light (WL) endoscopic examination.

Conditions

  • Gastroesophageal Reflux Disease
  • Reflux Esophagitis

Interventions

DEVICE

i-scan

For all the study procedures, Pentax EPKi processor and high-resolution adult video endoscopes (EG-2890i; Pentax, Japan) with push button switch from WL to i-scan were used. I-scan consist of three modes of image enhancement including SE, CE, ant TE. For SE and CE, switching among three enhancement levels (2+,3+,4+) is possible. Although SE and CE modes can allow detailed observation of subtle mucosal irregularities, noise increases as enhancement becomes more intense. In addition, TE is possible to switch p (pit pattern), v (vessel), b (Barrett), e (esophagus), g (stomach) and c (colo-rectum) mode.

Sponsors & Collaborators

  • Konkuk University Hospital

    lead OTHER

Principal Investigators

  • Sung Noh Hong, M.D. · Konkuk University Medical Center,Konkuk University School of Medicine

Study Design

Allocation
RANDOMIZED
Purpose
DIAGNOSTIC
Masking
SINGLE
Model
PARALLEL

Eligibility

Min Age
18 Years
Max Age
80 Years
Sex
ALL
Healthy Volunteers
Yes

Timeline & Regulatory

Start
2010-07-31
Primary Completion
2010-11-30
Completion
2011-06-30

Countries

  • South Korea

Study Locations

More Related Trials

Read the full study record

This page highlights key information. For complete eligibility criteria, study locations, investigator contacts, and the full protocol, visit the original record on ClinicalTrials.gov.