MOTIONPOD (TM) Validation and Calibration Study
NCT01317732 · Status: COMPLETED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 60
Last updated 2019-05-28
Summary
In this study we propose 1) to develop a new multisensor monitoring system associating a tri-axial accelerometer and a magnetometer to measure physical activity in free-living adults, 2) to perform its calibration and assess its validity in a series of activity tasks in comparison with the measure of energy expenditure by indirect calorimetry as the criterion measure, and with existing physical activity monitors (cardiofrequencemetry and accelerometers used either alone or in combination). Briefly the subjects will perform a series of standardized activity tasks of different intensities and a 30-min free physical activity period while wearing 6 MOTIONPOD(TM) and different commercial activity monitors. Physical activity energy expenditure will be measured using a metabolic gas analyser.
Data of the 30 first subjects will be used to develop new algorithms to identify the different activity tasks and to estimate the related energy expenditures. Data of the following 30 subjects will be used to validate the MotionPOD(TM) against indirect calorimetry and existing physical activity monitors
Conditions
- Energy Expenditure
Interventions
- DEVICE
-
MOTIONPOD (TM) measures
It is a study with a single arm. The MOTIONPOD TM measures are compared with simultaneous estimations obtained with the criteria measure (indirect calorimeter) and with existing activity monitors (heart rate monitor POLAR; different accelerometers - rT3 et Actigraph GT3X-, Actiheart, Sensewear Pro2 Armband) After physical fitness evaluation, different activity monitors are set up and the subjects perform a series of standardised activity tasks of different intensities, and well as a 30-min free activity period. Physical activity energy expenditure is measured at the end of each task using a metabolic gas analyser
Sponsors & Collaborators
-
Hospices Civils de Lyon
lead OTHER
Principal Investigators
-
Chantal SIMON, Pr,PhD, MD · Hospices Civils de Lyon Centre de Recherche en Nutrition Humaine Rhône-Alpes (CRNH-RA)
Study Design
- Allocation
- NA
- Purpose
- OTHER
- Masking
- NONE
- Model
- SINGLE_GROUP
Eligibility
- Min Age
- 18 Years
- Max Age
- 55 Years
- Sex
- ALL
- Healthy Volunteers
- Yes
Timeline & Regulatory
- Start
- 2010-10-31
- Primary Completion
- 2013-10-31
- Completion
- 2013-10-31
Countries
- France
Study Locations
More Related Trials
-
Digital Assessment of Real-World Walking Activity in Pulmonary Hypertension: A Prospective Multicenter Trial
NCT07137260 ·Status: RECRUITING
-
Validity of an Actigraph Accelerometer Following Critical Illness
NCT03295630 ·Status: COMPLETED ·Phase: NA
-
A Smartphone Application to Evaluate Energy Expenditure and Duration of Activities in Free-living Conditions (eMouve2)
NCT01995162 ·Status: COMPLETED ·Phase: NA
-
Validity and Reliability of Optical Heart Rate Sensors
NCT05525000 ·Status: COMPLETED ·Phase: NA
-
SHIFT-Hospital in Motion (Validation Study)
NCT06396676 ·Status: COMPLETED
-
AI-POD Clinical Validation Study for Obese Patients
NCT06595134 ·Status: RECRUITING
-
Pulse Oximetry_Performance Testing- PCBA-1 (Printed Circuit Board Assembly)
NCT01747460 ·Status: COMPLETED
-
Development of Tools for Respiration and Circulation Exploration
NCT02114749 ·Status: COMPLETED ·Phase: NA
-
A Prospective Patient Reported Outcomes and Wearables Study in Myeloproliferative Neoplasms
NCT06334913 ·Status: NOT_YET_RECRUITING
-
Setting up a Warehouse of Physiological Data and Biomedical Signals in Adult Intensive Care
NCT02893462 ·Status: RECRUITING
-
ECG Validation Study
NCT05445726 ·Status: ACTIVE_NOT_RECRUITING ·Phase: PHASE2
-
Validation of Two Acitivity Monitors in Three Inpatient Populations.
NCT04120740 ·Status: COMPLETED
-
Evaluation of a New System for Heart Rate and SpO2 Measurement.
NCT05240079 ·Status: UNKNOWN ·Phase: NA
-
UMIC Validation Study
NCT01708577 ·Status: COMPLETED ·Phase: NA
-
Portrait Mobile Monitoring Solution V2.0 External Evaluation
NCT07309809 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Observational, Non-Interventional Study Supporting Validation of VO2Max Estimation Methods Using Results in Patients Receiving Standard of Care Cardiopulmonary Exercise Tests (CPET)
NCT05678530 ·Status: RECRUITING
-
Comparative in Patient, Non-intervention Study of the Remote Physiological Monitoring System (RPM™) vs Standard Physiological Monitoring Devices
NCT00664924 ·Status: COMPLETED
-
Validation of Smart Garments for Metabolic Rate Estimation
NCT06026761 ·Status: COMPLETED
-
A Wireless Bed Sensor for Monitoring Coughs
NCT03177694 ·Status: UNKNOWN
-
Evaluation of Performance, Usability, and Reliability of a Novel Device for Continuous Collection of Physiological Data
NCT03257189 ·Status: COMPLETED ·Phase: NA
-
A Validation Study of Selfie Technology for Assessment of Vital Signs
NCT05117762 ·Status: UNKNOWN
-
The Validation Study of Bioelectronics
NCT05397951 ·Status: RECRUITING ·Phase: NA
-
Assessing the Feasibility of Multi-modal Biosensing for Monitoring Mobility and Cognition in Older Adults
NCT07217951 ·Status: NOT_YET_RECRUITING
-
Validity of Measuring Preoperative Fitness Using Seismofit
NCT05943730 ·Status: UNKNOWN ·Phase: NA
-
Wearable Devices Empowering Active Health Initiatives for High-Risk Stroke Populations
NCT06935513 ·Status: RECRUITING ·Phase: NA