Apollo Overstitch, a Treat and Resect Model
NCT01307813 · Status: COMPLETED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 4
Last updated 2022-02-24
Summary
The Overstitch (Apollo Endosurgery, Austin, Texas) is an FDA cleared product which attaches to a standard double channel endoscope. The Overstitch can place sutures under endoscopic guidance, with the goal of reproducing standard surgical techniques. These would include hemostasis, tissue approximation, anastomosis formation, fixation of intraluminal devices, or repair/closure of mucosal or full thickness defects such as perforations or endoscopic mucosal resection (EMR) sites. Knot tying of the endoscopically placed sutures is provided by an endoscopic cinching device that passes through the channel of the endoscope.
This feasibility trial will evaluate the ability of the Apollo suturing device (Overstitch) to endoscopically place sutures into normal mucosa, and then "tie" the sutures with the cinching device. These devices have been utilized effectively in explant, live porcine, and human cadaver colon and stomach models. In this treat and resect model, sutures would be placed in a segment of colon or stomach that is being surgically removed via open or laparoscopic technique for the treatment of benign or malignant disease. The sutures would be placed in a segment of normal mucosa remote to the pathology being surgically treated. In addition, the sutures will be placed under direct observation via laparoscopic or open visualization. After resection of the segment of colon, it will be evaluated grossly for level of suture placement, evidence of perforation, and quality of suture approximation with the cinching device.
Conditions
- Colon Malignant Tumor
- Colon Benign Tumor
Interventions
- DEVICE
-
Overstitch Endoscopic Suturing System
Assess the safety and effectiveness of the Apollo endoscopic suturing device (Overstitch) and cinching device for placement of sutures and surgical knots in a segment of colon under laparoscopic or open visualization of the operative area. Patients will already require resection of segments of colon for treatment of benign or malignant disease and this will therefore be a treat and resect model
Sponsors & Collaborators
-
Apollo Endosurgery, Inc.
collaborator INDUSTRY -
University Hospitals Cleveland Medical Center
lead OTHER
Principal Investigators
-
Jeffrey Marks, MD · University Hospitals Cleveland Medical Center
Study Design
- Allocation
- NA
- Purpose
- OTHER
- Masking
- NONE
- Model
- SINGLE_GROUP
Eligibility
- Min Age
- 18 Years
- Sex
- ALL
- Healthy Volunteers
- Yes
Timeline & Regulatory
- Start
- 2011-02-28
- Primary Completion
- 2011-11-30
- Completion
- 2011-11-30
Countries
- United States
Study Locations
More Related Trials
-
Cap Assisted Colonoscopy for the Detection of Colon Polyps
NCT01211132 ·Status: UNKNOWN ·Phase: NA
-
Transparent Cap-Assisted Colonoscopy Combined With Computer-Aided Detection in Improving the Detection Rate of Colorectal Adenomas
NCT07097350 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
The Utility of Cap Colonoscopy in Increasing Adenoma Detection Rate
NCT01601431 ·Status: TERMINATED ·Phase: NA
-
Endocuff Adenoma Detection Rate Pilot Study
NCT01761097 ·Status: UNKNOWN ·Phase: NA
-
Artificial Intelligence Development for Colorectal Polyp Diagnosis
NCT06447012 ·Status: RECRUITING
-
Use of a Novel Camera to Check the Bowel After Polyp or Tumour Removal
NCT07341126 ·Status: NOT_YET_RECRUITING
-
Suturing Through-the-scope System Used for Prophylactic Closure of Colonic Post-ESD Defects
NCT06443047 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
A Prospective Study to Evaluate the Performance of a Real-time System in the Estimation of Colorectal Polyp Size
NCT06957015 ·Status: RECRUITING ·Phase: NA
-
Utility of OverStitch Sx After ESD
NCT04361227 ·Status: COMPLETED
-
AI-assisted Detection of Missed Colonic Polyps
NCT04227795 ·Status: COMPLETED ·Phase: NA
-
Inspection of the Colon Using a Retrograde Viewing Device for Detection of Colorectal Polyps
NCT04107376 ·Status: UNKNOWN ·Phase: NA
-
Pivotal Study of the CapsoCam Colon (CV-3) in Detecting Colonic Polyps, Using Colonoscopy as the Reference
NCT04607746 ·Status: COMPLETED ·Phase: NA
-
The Real-time Optical Diagnosis Value of Optical Enhancement Endoscopy in Colorectal Sessile Serrated Adenomas/Polyps
NCT03238573 ·Status: UNKNOWN
-
AI in Predicting Polyp Pathology and Endoscopic Classification
NCT06773832 ·Status: RECRUITING
-
Artificial Intelligence-assisted System in Colonoscopy
NCT06406062 ·Status: RECRUITING
-
Artificial-intelligence-based QUAntification of Size measuremeNts of Adenoma in Routine Endoscopy
NCT06040710 ·Status: COMPLETED
-
Endoscopic Full Thickness Resection in the Lower GI Tract With the "Full Thickness Resection Device"
NCT02362126 ·Status: UNKNOWN
-
Efficacy and Safety of Cold Snare Polypectomy (CSP) of Intermediate Sized Colorectal Polyps 10-15 mm
NCT04464837 ·Status: UNKNOWN ·Phase: NA
-
Longterm Effectiveness of Artificial Intelligence-assisted Colonoscopy on Adenoma Recurrence
NCT06251700 ·Status: RECRUITING ·Phase: NA
-
Post-resection Treatment of Large Colon Polyps
NCT03654209 ·Status: COMPLETED ·Phase: NA
-
Endocuff-assisted Versus Cap-assisted Versus Standard Colonoscopy
NCT02331836 ·Status: COMPLETED ·Phase: NA
-
AI Colorectal Polyp Detection
NCT04979962 ·Status: COMPLETED ·Phase: NA
-
Gastrointestinal Anastomosis Using MonoPlus® Suture
NCT04811833 ·Status: WITHDRAWN
-
Adenoma Miss Rate in Tandem Endocuff-assisted Colonoscopy
NCT04805567 ·Status: UNKNOWN
-
Endocuff Vision Assisted vs. Standard Polyp Resection in the Colorectum
NCT03117114 ·Status: COMPLETED ·Phase: NA