Variable Ventilation During Acute Respiratory Failure

NCT01083277 · Status: TERMINATED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 7

Last updated 2017-07-11

No results posted yet for this study

Summary

Acute respiratory failure requiring support with mechanical ventilation occurs with an incidence of 77-100 per 100,000 person-years and accounts for half of all patients admitted to the intensive care unit. Major causes of acute respiratory failure include pneumonia, asthma, emphysema, and acute lung injury. These causes of acute respiratory failure may result in partial lung collapse (atelectasis), and airway narrowing (bronchoconstriction)that result in decreased oxygen levels requiring support with the ventilator. The prolonged inactivity in the supine position associated with mechanical ventilation can further result in atelectasis requiring increased oxygen supplementation through the ventilator.

The current standard of care in acute respiratory failure is a strategy of mechanical ventilation using a single lung volume delivered repeatedly. However, the current standard mechanical ventilation strategy is not consistent with the variability in respiration of healthy humans and has been shown to contribute to increased lung injury in some studies. The mortality associated with acute respiratory failure is high, 30-40%. Thus, improvements in mechanical ventilation strategies that improve oxygen levels and potentially decrease further lung injury delivered by the ventilator are warranted.

Recent studies by BU Professor Bela Suki and others in humans and animals with acute lung injury, bronchoconstriction, and atelectasis have shown that varying the lung volumes delivered by a ventilator significantly decreases biomarkers of lung injury, improves lung mechanics, and increases oxygenation when compared to identical mean volumes of conventional, monotonous low lung volume ventilation.

Therefore, we propose a first-in-human, Phase I study to evaluate the safety of this novel mode of ventilation, Variable Ventilation, during acute respiratory failure

Conditions

  • Acute Respiratory Failure

Interventions

DEVICE

variable ventilation

In variable ventilation, the tidal volume on the Puritan-Bennett 840 ventilator will be randomly varied by 40% on a breath-by-breath basis around a pre-set mean, using the variable ventilation software developed by Dr. Bela Suki and Dr. Arnab Majumdar. In conventional ventilation, the tidal volume on the Puritan-Bennett 840 ventilator will be set to equal the mean tidal volume used in variable ventilation and does not vary.

OTHER

Conventional ventilation

tidal volume will be set as the patient's baseline tidal volume prior to study entry and will not vary.

Sponsors & Collaborators

  • Wallace H. Coulter Foundation

    collaborator OTHER
  • Boston Medical Center

    lead OTHER

Principal Investigators

  • George T O'Connor, MD · Boston University

Study Design

Allocation
RANDOMIZED
Purpose
DEVICE_FEASIBILITY
Masking
NONE
Model
CROSSOVER

Eligibility

Min Age
18 Years
Sex
ALL
Healthy Volunteers
No

Timeline & Regulatory

Start
2012-09-30
Primary Completion
2016-07-31
Completion
2016-12-23
FDA Device
Yes

Countries

  • United States

Study Locations