Pulse Pressure Variation (PPV) to Predict Fluid Responsiveness During Cardiac Displacement in Patients Undergoing Off-pump Coronary Artery Bypass Surgery (OPCAB)
NCT01041742 · Status: COMPLETED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 35
Last updated 2010-07-27
Summary
Pulse pressure variation (PPV) known as a dynamic preload index is increasingly being used for guide of fluid management under various clinical situations. We hypothesized that PPV could play a role as a predictor of fluid responsiveness during displacement of the heart in patients undergoing off-pump coronary artery bypass surgery (OPCAB).
Conditions
- Ischemic Heart Disease
Interventions
- PROCEDURE
-
fluid loading
fluid loading will be performed by using 6% hydroxyethyl starch solution , at 10 mL/kg.
Sponsors & Collaborators
-
Seoul National University Hospital
lead OTHER
Principal Investigators
-
Yunseok Jeon, MD · Seoul National University Hospital
Study Design
- Allocation
- NA
- Purpose
- PREVENTION
- Masking
- NONE
- Model
- SINGLE_GROUP
Eligibility
- Min Age
- 18 Years
- Max Age
- 80 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2009-12-31
- Primary Completion
- 2009-12-31
- Completion
- 2010-01-31
Countries
- South Korea
Study Locations
More Related Trials
-
The Use of Tidal Volume Challenge of Dynamic Parameters During Laparoscopic Surgery
NCT03467711 ·Status: COMPLETED
-
Dynamic Preload Parameters During Liver Transplantation
NCT01971333 ·Status: UNKNOWN
-
Hemodynamic Indices Predictive of a Beneficial Response to Fluid Expansion in Case of Hemodynamic Failure After Cardiac Surgery With Altered Preoperative Ejection Fraction (LVEF≤45%)
NCT01673230 ·Status: COMPLETED ·Phase: NA
-
Goal-directed Fluid Therapy During Deep Inferior Epigastric Perforator (DIEP) Free Flap Breast Reconstruction
NCT06080178 ·Status: RECRUITING ·Phase: PHASE4
-
Intraoperative Fluid Management Based on Arterial Pulse Pressure Variation During High-Risk Surgery
NCT00479011 ·Status: TERMINATED ·Phase: NA
-
Assessment of the Evolutions of Transcutaneous CO2 With the Modification of Blood Flow During On-pump Cardiac Surgery
NCT02362841 ·Status: COMPLETED
-
Pressure Gradient for Venous Return in Predicting Fluid Responsiveness in Patients Undergoing Laparoscopic Surgery
NCT04030221 ·Status: UNKNOWN
-
Pontos-Central Venous Pressure and Cardiac Surgery
NCT03423420 ·Status: COMPLETED
-
PWV for Cardiovascular Complication After Cardiac Surgery
NCT02014012 ·Status: COMPLETED
-
Dynamic Tests and Parameters to Predict Fluid Responsiveness After OPCAB
NCT04482946 ·Status: UNKNOWN ·Phase: NA
-
Correlation Between ΔPP/HR and ΔSV During Fluid Challenge.
NCT02439242 ·Status: UNKNOWN
-
Individualized Blood Pressure Management in Patients Undergoing Cardiac Surgery
NCT03784690 ·Status: WITHDRAWN ·Phase: NA
-
Dynamic Preload Indicators in Sitting Position
NCT02000570 ·Status: COMPLETED ·Phase: NA
-
Controling Mean Arterial Pressure Using a Closed-Loop System for Vasopressor Titration
NCT04586218 ·Status: COMPLETED ·Phase: NA
-
Assessments of Dynamic Variables of Fluid Responsiveness to Predict Desufflation-induced Hypotension in Urologic Patients Undergoing Laparoscopic Surgery
NCT03967119 ·Status: UNKNOWN
-
The Utility of Pulse Pressure Variation to Predict the Fluid Responsiveness During Pneumoperitoneum and Reverse-Trendelenburg Position
NCT02771067 ·Status: COMPLETED ·Phase: NA
-
Parameters of Cerebral Perfusion
NCT02806492 ·Status: COMPLETED ·Phase: NA
-
Impact of Positive End-expiratory Pressure on Hepatic Venous Flow
NCT02700581 ·Status: UNKNOWN ·Phase: NA
-
Dynamic Preload Dependence Indices in Laparoscopic Surgery
NCT02541656 ·Status: COMPLETED ·Phase: NA
-
Dynamic Estimation of Cardiac Output in the Operating Room
NCT04926220 ·Status: UNKNOWN
-
Effect of Intraoperative Volume Optimization on Outcome After Intrabdominal Surgery
NCT00766519 ·Status: COMPLETED ·Phase: PHASE4
-
In Situ Exploration of Vascular Function in Vasoplegic Shock Following Cardiac Surgery With Cardiopulmonary Bypass
NCT06318689 ·Status: RECRUITING
-
Multi-center Trial of Goal-directed Fluid Management Based on Pulse Pressure Variation Monitoring
NCT03128190 ·Status: COMPLETED ·Phase: NA
-
Evaluation of a Non-invasive Device to Measure Blood Pressure and Difference in Pulse Pressure (dPP) Intraoperatively
NCT02009020 ·Status: COMPLETED
-
Casptesia Versus PICCO in Cardiac Surgical Patients in the ICU
NCT03727503 ·Status: TERMINATED ·Phase: NA