Spontaneous Atrio Ventricular Conduction Preservation
NCT00655213 · Status: COMPLETED · Phase: PHASE4 · Type: INTERVENTIONAL · Enrollment: 622
Last updated 2008-04-09
Summary
In case of sinus node dysfunction, it is often necessary to choose the safer option provided by a DDD pacemaker even though the most appropriate mode of pacing is AAI mode.
In addition to saving energy, the latter mode allows spontaneous ventricular activation, the haemodynamic consequences of which are, in most cases, better than those obtained with dual chamber pacing.
Recent studies as the MOST study suggest also that ventricular desynchronization imposed by right ventricular apical pacing even when AV synchrony is preserved increases the risk of atrial fibrillation in patients with SND. Similar results were already given by anterior studies (PIPAF) which, taking into account the percentage of ventricular pacing, suggested that AF prevention algorithm in combination with a preserved native conduction are efficient in reducing AF burden.
However, current practice is to implant a dual chamber pacemaker to prevent the risk of atrioventricular block (AVB) even if DDDR pacing with a fixed long AV delay was found inefficient in reducing ventricular pacing and was associated with a high risk of arrhythmias.
The Symphony 2550 cardiac pacemaker offers pacing modes that automatically switch from AAI(R) mode to DDD(R) or DDI(R) in event of severe atrioventricular conduction disorder, irrespective of whether or not these are accompanied by an atrial arrhythmia, returning spontaneously to AAI(R) mode as soon as the spontaneous AV conduction has resumed. These 2 particular modes are called the AAI SafeR and DDD/AMC (R) mode.
The main differences between both modes are that (i) AAI SafeR does not trigger any AV Delay after a sensed or paced atrial event which allows long PR intervals or even limited ventricular pauses with no switch to DDD(R), while (ii) DDD/AMC (R) is able to optimize AV Delay after switching to DDD(R) according to measured spontaneous conduction times and to provide an acceleration in case of vaso-vagal syndrome. This pacing mode has previously been assessed in clinical studies.
This study intends to demonstrate that the automatic modes switching significantly reduce the percentage of ventricular pacing in patients implanted with a spontaneous AV conduction and reduce the occurrence of atrial arrhythmias, on a mid-term follow-up period, in comparison to standard DDD pacing with long AVDelay.
Conditions
- Sinus Node Dysfunction
- Bradycardia-Tachycardia Syndrome
- Paroxysmal Atrioventricular Block
Interventions
- DEVICE
-
Symphony D 2450
- DEVICE
-
Symphony DR 2550
Sponsors & Collaborators
-
LivaNova
lead INDUSTRY
Principal Investigators
-
Jean Marc DAVY, PhD · CH Montpellier
Study Design
- Allocation
- RANDOMIZED
- Purpose
- TREATMENT
- Masking
- DOUBLE
- Model
- PARALLEL
Eligibility
- Min Age
- 18 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2003-11-30
- Primary Completion
- 2006-12-31
- Completion
- 2006-12-31
Countries
- Belgium
- France
- Germany
- Italy
- United Kingdom
Study Locations
More Related Trials
-
To Pace or Not to Pace in Sinus Node Disease
NCT02485093 ·Status: COMPLETED ·Phase: NA
-
Risk of Pacing-induced Cardiomyopathy
NCT04269733 ·Status: COMPLETED
-
The Application of Negative Atrioventricular Hysteresis in Cardiac Resynchronization Therapy With MultiPoint Pacing
NCT02782598 ·Status: COMPLETED
-
Comparison of the Efficacy and Safety of Cardioneuroablation to Permanent Pacing in Patients With an Implanted Pacemaker for Symptomatic Bradycardia.
NCT05896592 ·Status: RECRUITING ·Phase: NA
-
Cardioneuroablation Versus Pacemaker Implantation for the Treatment of Symptomatic Sinus Node Dysfunction
NCT05186220 ·Status: UNKNOWN ·Phase: NA
-
Left Bundle Branch Pacing Versus Conventional Pacing in Atrioventricular Block
NCT05129098 ·Status: COMPLETED ·Phase: NA
-
Synchrony in Cardiac Conduction: Assessing the Effects of Pacing on Cardiac Performance Through Magnetic Resonance Imaging and Advanced ECG-imaging
NCT06843135 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Pacing to Maintain Physiologic Ventricular Activation
NCT04416958 ·Status: RECRUITING
-
Acute and Chronic Effect of His-pacing in Consecutive Patients With AV-block
NCT01019213 ·Status: COMPLETED ·Phase: PHASE4
-
An-Art Study: Atrioventricular (AV) Node Ablation in Cardiac Resynchronisation Therapy
NCT00260546 ·Status: WITHDRAWN ·Phase: EARLY_PHASE1
-
AV-node Stimulation Clinical Download Study to Reduce Ventricular Rate During AF
NCT01095952 ·Status: COMPLETED ·Phase: NA
-
Prevention of Syncope by Cardiac Pacing in Patients With Bifascicular Block
NCT01463358 ·Status: COMPLETED ·Phase: NA
-
Left Ventricular Function and Remodelling During Permanent Pacing
NCT00228241 ·Status: UNKNOWN ·Phase: NA
-
Biventricular Alternative Pacing
NCT00559143 ·Status: WITHDRAWN ·Phase: PHASE4
-
Effect of Closed Loop Pacemaker Treatment on Recurrent Vasovagal Syncope
NCT00292825 ·Status: COMPLETED ·Phase: NA
-
Cohort Description of Younger With AV-block
NCT03024047 ·Status: UNKNOWN
-
ISSUE3: International Study on Syncope of Uncertain Etiology 3
NCT00359203 ·Status: COMPLETED ·Phase: PHASE4
-
His Pacing Feasibility and Cardiac Electrical Activation
NCT04739553 ·Status: UNKNOWN ·Phase: NA
-
Right Ventricular Lead Placement in a Pacemaker Population: Evaluation of Apical and Alternative Position
NCT01647490 ·Status: UNKNOWN ·Phase: NA
-
Impact of Atrio-ventricular Optimization With His Bundle Pacing on Treatment of Atrio-ventricular Dromotropathy
NCT04544345 ·Status: COMPLETED ·Phase: NA
-
Renal Denervation in Hypertrophic Cardiomyopathy
NCT05577208 ·Status: UNKNOWN ·Phase: NA
-
Conduction System Pacing Versus Biventricular Pacing After Atrioventricular Node Ablation
NCT05467163 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
A Prospective Incident Study of Arrhythmias in Hypertrophic Cardiomyopathy
NCT04112290 ·Status: ACTIVE_NOT_RECRUITING
-
NOACs for Atrial Tachyarrhythmias in Congenital Heart Disease
NCT02928133 ·Status: UNKNOWN
-
Right Ventricular Septal Versus Apical Pacing: Echocardiographic Study
NCT06045143 ·Status: UNKNOWN