Pascal Pascal Dynamic Contour Tonometer (DCT) Intraocular Pressure and Ocular Pulse Amplitude in Patients With Thyroid Related Orbitopathy: A Comparison to Goldmann Tonometer and to Muscles Characteristics on CT Scan
NCT00646295 · Status: UNKNOWN · Phase: NA · Type: INTERVENTIONAL · Enrollment: 30
Last updated 2008-06-19
Summary
Thyroid related orbitopathy (TRO) is an autoimmune disease. Clinical features include: orbital pressure pain, ocular soft tissue swelling, muscle enlargement around the eyeball, eyelid retraction and bulging of the eye anteriorly out of the orbit. In many cases, the cornea may become too dry, and as a result, corneal ulcers may form, which can become infected. In severe cases, damage to the optic nerve can occur secondary to optic nerve compression by enlarged muscles in the orbit.
Inflammation with soft tissue swelling occurs in the 1st stage of the disease. Scar formation can occur in the 2nd phase. The muscles under and nasal to the eyeball are most commonly involved. In many patients, intra-ocular pressure (IOP) can increase in primary. IOP in upgaze (when looking up) can increase.
Goldmann applanation is the standard device to measure the IOP. It measures the average IOP (between the "systolic", when the heart contracts, to the diastolic IOP, when the heart relaxes). Pascal Dynamic Contour Tonometer is a new device that can measure IOP and ocular pulse amplitude (OPA) which is the difference between diastolic IOP and systolic IOP. The choroid is a vascular layer inside the eyeball that feeds part of the retina (the retina is like the film in a non-digital camera). OPA is suggestive of choroidal blood flow. IOP measurements using Pascal Dynamic Contour Tonometer are less influenced by corneal thickness as opposed to Goldmann applanation which measures higher values in thicker corneas. In the current study we are interested in measuring the relationships between measurements taken with Goldmann applanation (IOP) and those taken with the Pascal Dynamic Contour Tonometer (IOP and OPA). In addition, we will investigate the effect of orbital muscle enlargement on IOP/OPA following an up gaze position (looking up).
Conditions
- Thyroid Related Orbitopathy
Interventions
- DEVICE
-
To measure the IOP (with Goldmann and Pascal DCT tonometers) and OPA (with Pascal DCT) in primary and upright gazes
Pascal Dynamic Contour Tonometer Goldmann Applanation Tonometer
Sponsors & Collaborators
-
Sheba Medical Center
lead OTHER_GOV
Study Design
- Allocation
- NA
- Purpose
- DIAGNOSTIC
- Masking
- NONE
- Model
- SINGLE_GROUP
Eligibility
- Min Age
- 18 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2008-06-30
- Primary Completion
- 2010-06-30
- Completion
- 2010-09-30
Countries
- Israel
More Related Trials
-
Choroidal Thickness During Changes in Intraocular Pressure and Arterial Blood Pressure
NCT01333891 ·Status: TERMINATED ·Phase: NA
-
Evaluation of Blood Flow Characteristics in Glaucoma Using Optical Coherence Tomography Angiography (OCT-A).
NCT02757677 ·Status: TERMINATED
-
The Intraocular Pressure Measured by Different Tonometers in Corneal Edema
NCT01998568 ·Status: COMPLETED
-
Anterior-segment OCT (AS-OCT) and Intraoperative OCT (iOCT) for Trans- Conjunctival Needle Revision (TCNR)
NCT05790408 ·Status: TERMINATED ·Phase: NA
-
Effects of a PF Ophthalmic Solution Containing HA0.4% and TAU 0.5%
NCT03480295 ·Status: COMPLETED ·Phase: NA
-
Corneal Biomechanics and Continuous IOP Monitoring Using Soft Contact Lenses in Glaucomatous Patients
NCT01849536 ·Status: COMPLETED ·Phase: NA
-
Comparison of Intraocular Pressure Measurement With the Novel TonoVera Device With Other Commonly Used Devices
NCT05523622 ·Status: RECRUITING ·Phase: NA
-
Different Glaucoma Treatments Effect on Intraocular Pressure Fluctuation With Postural Change in Eyes With Open-angle Glaucoma
NCT02868502 ·Status: UNKNOWN
-
Comparison of Sensimed Triggerfish With Goldmann Applanation Tonometry and Perkins Tonometry
NCT01391078 ·Status: COMPLETED ·Phase: NA
-
The Effect of Ocular Massage on the Management of Elevated Intraocular Pressure After Acute Angle Closure
NCT02539758 ·Status: COMPLETED ·Phase: NA
-
R&D of Non-invasive Innovative Intracranial Waves Monitoring System for Diagnostics and Treatment Monitoring of Patients with Normal Tension Glaucoma
NCT06443411 ·Status: ENROLLING_BY_INVITATION
-
Efficacy of 24-hour Intraocular Pressure Fluctuation Recording With the SENSIMED Triggerfish Contact Lens Sensor
NCT01390779 ·Status: COMPLETED ·Phase: NA
-
Blood Flow of Ophthalmic Artery and Glaucoma
NCT02656979 ·Status: UNKNOWN ·Phase: NA
-
The Effect of Trabeculectomy & Ex-PRESS Glaucoma Drainage Implant on the Corneal Biomechanical Properties
NCT04648943 ·Status: COMPLETED ·Phase: NA
-
Effect of Raised End-Tidal pCo2 on Choroidal Volume
NCT06275308 ·Status: RECRUITING ·Phase: NA
-
Evaluation of the Water Drinking Test Response in Supine and Sitting Position Using the Continuous Measurement Device Sensimed Triggerfish Intraocular Pressure in Healthy Subjects
NCT02843971 ·Status: COMPLETED ·Phase: NA
-
Comparative Study Between Tonometers
NCT03338101 ·Status: COMPLETED
-
Automatic Evaluation of the Anterior Chamber Angle Width by a New Non-contact Optical Device
NCT06278597 ·Status: COMPLETED ·Phase: NA
-
Intraocular Pressure Data Collection With Tonometers
NCT06450587 ·Status: COMPLETED ·Phase: NA
-
aICP in Glaucoma and Papilledema
NCT02410148 ·Status: UNKNOWN ·Phase: NA
-
Assessing Ocular Hemodynamic Response to Surgical Intervention in Glaucoma
NCT02891317 ·Status: TERMINATED
-
24h Continuous Intraocular Pressure (IOP) Monitoring vs Goldmann Applanation Tonometry
NCT01217853 ·Status: COMPLETED
-
The Response of Intraocular Pressure to Systemic Hypercapnia and Hyperoxia
NCT01325285 ·Status: UNKNOWN
-
Relationship Between 24-hour IOP Pattern and the 24-hour Blood Pressure Pattern in Patients With POAG
NCT01769521 ·Status: COMPLETED ·Phase: NA
-
Intraocular Pressure During Robotic Assisted Laparoscopic Procedures Utilizing Steep Trendelenburg Positioning
NCT01261871 ·Status: COMPLETED