Anterior-segment OCT (AS-OCT) and Intraoperative OCT (iOCT) for Trans- Conjunctival Needle Revision (TCNR)

NCT05790408 · Status: TERMINATED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 10

Last updated 2023-11-15

Study results available
· View outcomes & findings →

Summary

Trabeculectomy is a very important and commonly performed glaucoma operation. It allows fluid from inside the eye to exit into a space called a bleb located on the surface of the eye under the upper eyelid. The formation of excessive scar tissue after surgery may cause the operation to work less well or stop working. This results in an increase in eye pressure. The use of a needle to cut the scar tissue is a commonly used procedure. This surgery is called trans-conjunctival needle revision (TCNR) of trabeculectomy bleb.

The study aims to determine if advanced optical imaging called Optical Coherence Tomography (OCT) of the scar tissue both in the office prior to surgery and during surgery in the operating room improves the success rate of the revision surgery. These devices are FDA approved and have been used extensively in ophthalmology and ocular surgery.

Ophthalmologists already used these imaging devices for this purpose as part of the standard medical care of some patients. The purpose of this study is to prospectively gather information about its use in a systematic way. Furthermore, investigators want to determine if imaging improves outcomes compared to historical controls (patients who underwent the same surgery in the past without imaging). The potential benefit of this research is that it may provide knowledge that will be of benefit to future patients with glaucoma who are undergoing this procedure.

Conditions

Interventions

DEVICE

Digital microscope integrated with intraoperative OCT (Zeiss Artevo 800, Carl Zeiss Meditec AG)

The Zeiss Artevo digital microscope integrated with iOCT (Zeiss Artevo 800, Carl Zeiss Meditec AG) is a commercially available, FDA approved device that can be utilized to visualize and evaluate the morphology of the trabeculectomy bleb during transconjunctival needle revision of trabeculectomy bleb.

DEVICE

Spectralis Anterior-segment OCT (AS-OCT) (Heidelberg Engineering)

The Spectralis Anterior-segment OCT (AS-OCT) is a commercially available, FDA approved device that can be utilized to visualize and evaluate the morphology of the trabeculectomy bleb in the office.

Sponsors & Collaborators

Principal Investigators

  • Angelo P Tanna, MD · Professor

Study Design

Allocation
NA
Purpose
TREATMENT
Masking
NONE
Model
SINGLE_GROUP

Eligibility

Min Age
18 Years
Sex
ALL
Healthy Volunteers
No

Timeline & Regulatory

Start
2020-08-18
Primary Completion
2022-01-12
Completion
2022-01-12
FDA Device
Yes

Countries

  • United States