Strategies for Aggressive Central Afterload Reduction in Patients With Heart Failure

NCT00588692 · Status: COMPLETED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 60

Last updated 2014-05-06

Study results available
· View outcomes & findings →

Summary

Heart failure (HF) is the leading cause of hospitalization among Americans over the age of 65 years, affecting greater than 5 million in the U.S. alone. Significant improvements in morbidity and mortality have been achieved through the use of medications that antagonize adverse neurohormonal signaling pathways, particularly therapies that reduce left ventricular (LV) afterload.

Vascular stiffness increases with aging, contributing to the increase in cardiac load. One important repercussion of such stiffening is an increase in pulse wave velocity. As the incident pressure wave generated by cardiac ejection encounters zones of impedance mismatch (such as arterial bifurcations), part of the wave is reflected backward, summing with the incident wave, increasing central blood pressure (CBP). With normal aging, hypertension, and heart failure, increased wave velocity causes the reflected wave to reach the heart earlier, in mid to late systole, considerably increasing late-systolic load, impairing cardiac ejection, and diastolic relaxation in the ensuing cardiac cycle.

The magnitude of this reflected pressure wave can be quantified by the augmentation index (AIx). The use of vasoactive agents which antagonize this increase in late systolic load (and AIx) may prove useful in the treatment of heart failure, by facilitating cardiac ejection during late systole when reflected pressure waves predominate. However, it has never been conclusively shown in humans that CBP-targeted therapy is useful in the management of HF.

LV afterload, measured centrally in the ascending aorta, may differ considerably from brachial cuff-measured pressure, and has traditionally required invasive hemodynamic assessment to determine, limiting the applicability of techniques targeting CBP and late-systolic load. Recently, a novel, hand-held tonometer (SphygmoCor, Atcor Medical) has been developed for the noninvasive assessment of CBP. This pencil-like device is applied over the radial artery, and uses a validated mathematical transformation to derive central aortic pressure. This device has received FDA approval for clinical use in the assessment of central pressures. However, it remains unknown whether knowledge of CBP and late-systolic load (AIx) confers any clinically-significant incremental benefit in the management of patients with heart failure. The primary objective of the proposed investigation will be to determine if this assessment might have such a role.

Conditions

Interventions

DEVICE

SphygmoCor

The SphygmoCor, a hand-held tonometer will assess central blood pressure noninvasively. This pencil-like device is applied over the radial artery, and uses a validated mathematical transformation to derive central aortic pressure.

Sponsors & Collaborators

  • AtCor Medical, Inc.

    collaborator INDUSTRY
  • Mayo Clinic

    lead OTHER

Principal Investigators

  • Barry A. Borlaug, MD · Staff Physician, Mayo Clinic

Study Design

Allocation
RANDOMIZED
Purpose
TREATMENT
Masking
SINGLE
Model
PARALLEL

Eligibility

Min Age
18 Years
Sex
ALL
Healthy Volunteers
No

Timeline & Regulatory

Start
2007-07-31
Primary Completion
2012-11-30
Completion
2012-12-31

Countries

  • United States

Study Locations

More Related Trials

Entities

Read the full study record

This page highlights key information. For complete eligibility criteria, study locations, investigator contacts, and the full protocol, visit the original record on ClinicalTrials.gov.

View NCT00588692 on ClinicalTrials.gov