Functional Evaluation of Two Types of Totally Implanted Venous Ports
NCT00484848 · Status: COMPLETED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 200
Last updated 2009-01-26
Summary
Totally implanted venous access ports allow a safe delivery of medication, mainly chemotherapy, but are also used for blood sampling. This last procedure is not always successful, as it appeared from a nurse's survey in different hospitals in Flanders, including the University Hospitals in Leuven, Belgium. In 3 to 29 percent of the attempts, blood withdrawal is impaired or not possible, as an intermittent or permanent fact. This is in line with international literature data where difficulty in blood draw was noted in 6 to 26% of port accessions. Partial or total occlusion leads to discomfort for the patient, delay in therapy, higher costs and extra nursing time.
A new port system with a tangential outlet (Vortex port) was designed and according to the manufacturer, this shape will allow to cleanse the entire reservoir of the port more efficiently and avoid the formation of precipitates of medication or blood that could lead to an obstruction of the device. These precipitates are also regarded as a potential risk factor for infection.
However, only one previously published small randomised study addressed the value of the Vortex port when compared to conventional access devices: Stevens et al. were able to show a reduction in obstruction incidence from 26% to 7% with the use of the Vortex port. The incidence of blood withdrawal problems in our experience with conventional ports in University hospitals Leuven was 8% thus lower than that reported by Stevens, but this remains the most frequent problem faced by care providers and patients.
With this study, the investigators aim to compare the performance of the tangential outlet ports and that of a "conventional" port in order to assess an eventual functional difference.
Conditions
- Hematologic Disease
Interventions
- DEVICE
-
Vortex port and Celsite port
Sponsors & Collaborators
-
RITA Medical Systems
collaborator INDUSTRY -
B. Braun Medical SA
collaborator INDUSTRY -
Universitaire Ziekenhuizen KU Leuven
lead OTHER
Principal Investigators
-
Marguerite Stas, MD PhD · KU Leuven
Study Design
- Allocation
- RANDOMIZED
- Purpose
- SUPPORTIVE_CARE
- Masking
- SINGLE
- Model
- PARALLEL
Eligibility
- Min Age
- 18 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2004-09-30
- Primary Completion
- 2004-12-31
- Completion
- 2005-03-31
Countries
- Belgium
Study Locations
More Related Trials
-
Central Venous Access Device Removal in Cancer Patients
NCT03855969 ·Status: COMPLETED
-
PORTAS 2, Comparing Venae Sectio Versus Punction of Vena Subclavia for Insertion of a Totally Implantable Access Port
NCT00600444 ·Status: COMPLETED ·Phase: NA
-
Evaluation of Performance Over Dwell Time and Safety of the Central-venous Catheters Certofix® Paed
NCT05124821 ·Status: COMPLETED
-
Improved Outcomes With Pre-Procedure Shockwave IVL of Common Femoral Artery Access Site Prior to Large Bore Access and Pre-Closure
NCT07205068 ·Status: RECRUITING ·Phase: NA
-
Safety and Efficacy of the URECA CTO Device
NCT04385381 ·Status: TERMINATED ·Phase: NA
-
RIPT Feasibility Trial
NCT03070834 ·Status: COMPLETED ·Phase: NA
-
Evaluation of the Surfacer System Approach to Central Venous Access
NCT03209050 ·Status: COMPLETED ·Phase: NA
-
Using the Accuvein Device for Patients Who Are Difficult to Perfuse
NCT06861595 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Vital Peripheral Intravenous Catheter Feasibility
NCT07016607 ·Status: COMPLETED ·Phase: NA
-
AMBULATE: Cardiva Mid-Bore VVCS vs. Manual Compression for Multiple Femoral Venous Access Sites, 6 - 12F ID
NCT03193021 ·Status: COMPLETED ·Phase: NA
-
AMBULATE Continued Access Protocol to Evaluate the Cardiva Mid-Bore Venous Vascular Closure System (VVCS)
NCT03573206 ·Status: COMPLETED ·Phase: NA
-
Distal vs Conventional Transradial Access for Coronary Procedures
NCT07138170 ·Status: COMPLETED ·Phase: NA
-
Effectiveness of Antibiotic Prophylaxis for Totally Implantable Venous Access Device
NCT00867295 ·Status: COMPLETED ·Phase: PHASE3
-
Vascular Access in Cancer Patients - PICC vs PORT in a Randomized Controlled Trial.
NCT01971021 ·Status: COMPLETED ·Phase: NA
-
A Randomized Controlled Open Label Trial to Assess the Safety and Efficacy of the OptiVein IV Catheter in an Oncologic Population
NCT02420028 ·Status: TERMINATED ·Phase: NA
-
Concentrated Citrate Locking to Reduce the Incidence of CVC-related Complications in Hematological Patients
NCT01820962 ·Status: TERMINATED ·Phase: PHASE3
-
A Retrospective, Observational, Monocenter, Study to Describe the Utilization and Overall Safety and Performance of POLYSITE®/SEESITE® Implantable Ports
NCT05519787 ·Status: COMPLETED
-
Satisfaction With Placement of Implantable Venous Access Devices in Patients With Solid Tumors
NCT01098643 ·Status: TERMINATED ·Phase: NA
-
Vascular Access Complications for Therapeutic Apheresis in Nephrology
NCT05894317 ·Status: COMPLETED
-
Clinical Investigation for Safety and Efficacy Study of CELT ACD (Arterial ClosureDevice)
NCT01600482 ·Status: COMPLETED ·Phase: NA
-
Assess Veinplicity Venous Access Device Safety and Effectiveness
NCT03109405 ·Status: COMPLETED ·Phase: NA
-
Impact of Availability of Showerpatch for Patients With Intravenous Catheters
NCT02324868 ·Status: TERMINATED ·Phase: NA
-
Observational Peripheral IV Insertion Study
NCT04762121 ·Status: WITHDRAWN
-
Comparison Between Two Optional IVC Filters Regardind Ease of Use,Complications and Outcome
NCT00588757 ·Status: UNKNOWN ·Phase: NA
-
Two is Better Than One: A Novel Venous Access System for Intermittent Apheresis
NCT04846374 ·Status: COMPLETED