Evaluation of New Test Method to Measure Kidney Function
NCT00026715 · Status: COMPLETED · Type: OBSERVATIONAL · Enrollment: 150
Last updated 2008-03-04
Summary
This study will test the accuracy of a new "Fast GFR" (glomerular filtration rate) test to evaluate kidney function. Accurate assessment of kidney function is important in many clinical situations, including detecting kidney disease early, determining appropriate drug dosages, deciding when to begin dialysis, and evaluating heart and kidney organ donors and recipients. The current GFR test is used mostly for research purposes, as it is too costly and complicated for general medical use. Another significant drawback to its use in diagnosing acute kidney failure is the time it takes (3 to 24 hours) to complete, since effective therapy for this condition requires its detection as soon as possible. The Fast GFR, by comparison, takes only 45 minutes.
Patients 6 years old and older with kidney disease or with impaired kidney function caused by abnormal heart function or swelling-from congestive heart failure, severe infections, swelling from fluid accumulation, fluid in the abdomen, or burns-may be eligible for this study. Patients will undergo both the standard and the Fast GFR tests, described below, to evaluate the accuracy of the new test.
Fast GFR: Two catheters (thin flexible tubes) are placed into two arm veins, one for injecting iothalamate-an agent commonly used in CT scanning and blood vessel imaging-and the other for collecting blood samples. Baseline blood and urine samples are collected and then 0.5 milliliter (ml) iothalamate is injected into a vein. Blood samples are collected at 5, 10, 15, 20, 30, and 45 minutes in adults and at 5, 15, and 45 minutes in children. Urine is collected at 45 minutes. The size of the bladder is measured using ultrasound to determine if the bladder has completely emptied.
Standard GFR: Iothalamate (1 ml) is injected under the skin. Blood samples are collected at 60, 90, 120, 180 and 240 minutes. (A heparin lock is used to avoid multiple needle sticks.) Urine is collected at 60, 90, 120, 180 and 240 minutes. The size of the bladder is measured using ultrasound to determine if the bladder has completely emptied.
Conditions
Sponsors & Collaborators
-
National Institute of Diabetes and Digestive and Kidney Diseases (NIDDK)
lead NIH
Eligibility
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2000-06-30
- Completion
- 2002-06-30
Countries
- United States
Study Locations
More Related Trials
-
Estimation of Glomerular Filtration Rate (GFR) in Patients With Type 2 Diabetes Mellitus.
NCT01215994 ·Status: UNKNOWN
-
Risk of Chronic Kidney Disease Progression
NCT02654756 ·Status: COMPLETED
-
Accuracy of Glomerular Filtration Rate (GFR) Estimation Using Creatinine and Cystatin C and Albuminuria
NCT02433002 ·Status: UNKNOWN
-
Comparison of Markers of Kidney Function
NCT01403766 ·Status: COMPLETED
-
DKK3 for Prognosis and Monitoring of GFR Decline in Heart Failure
NCT04111094 ·Status: COMPLETED
-
GFR Measurement With Contrast-enhanced Dynamic MRI
NCT00614081 ·Status: COMPLETED ·Phase: NA
-
Glomerular Filtration Rate (GFR) Reporting on Nephrology Referral Patterns by Internists
NCT00134797 ·Status: WITHDRAWN
-
Fast Field Cycling Imaging of Kidney Disease
NCT05851417 ·Status: COMPLETED ·Phase: NA
-
The Study on the Effectiveness of [68Ga]Ga-HBED-CC-DiAsp PET/CT in Calculating GFR and Predicting Residual Renal Function After Partial Nephrectomy
NCT06973798 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Measurement of Kidney Blood Flow and Oxygen Levels by MRI
NCT01318967 ·Status: COMPLETED ·Phase: NA
-
Study Evaluating Novel Biomarkers of AKI (Acute Kidney Injury) in Post-operative Patients
NCT02499185 ·Status: TERMINATED ·Phase: PHASE4
-
Assessment of Renal Physiology by Magnetic Resonance Imaging (MRI) in Normal Volunteers
NCT00936416 ·Status: COMPLETED ·Phase: NA
-
Nova Max Creatinine and eGFR Meter System
NCT05118074 ·Status: COMPLETED
-
Canadian Study of Prediction of Risk and Evolution to Dialysis, Death and Interim Cardiovascular Events Over Time
NCT00826319 ·Status: UNKNOWN
-
A Study to Examine Past Estimated Glomerular Filtration Rate (eGFR) Slope as a Risk Marker for Rapid Kidney Function Decline in People With Chronic Kidney Disease
NCT04881448 ·Status: TERMINATED ·Phase: PHASE2
-
Assessment of Blood Pressure Control and Target Organ Damage in Patients With Chronic Kidney Disease and Hypertension -II
NCT02078115 ·Status: UNKNOWN
-
S-cystatin C vs.Injection Clearance Measurements to Estimate Kidney Function in Patients With Spinal Cord Injuries
NCT06565351 ·Status: COMPLETED
-
Establishing a New Ultrasound Technique to Improve Assessment of Chronic Kidney Disease.
NCT06159439 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Urinary Tubular Biomarkers for Chronic Kidney Disease
NCT06732349 ·Status: RECRUITING
-
Efficacy of Point-Of-Care Creatinine Assays in Patients With eGFR <30 Receiving Intravascular Contrast
NCT04597892 ·Status: WITHDRAWN
-
Evaluation of the Performance of Glomerular Filtration Rate Measurement Using CT Urography in Patients With a GFR Below 60 mL/Min/1.73 m²
NCT07042698 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Kidney Function in People With Cystic Fibrosis in the Era of HEMT
NCT06595420 ·Status: RECRUITING
-
Rapid Kidney Function Decline in Older Adults
NCT06765811 ·Status: COMPLETED
-
Evaluation of Novel Biomarkers From Acutely Ill Patients at Risk for Acute Kidney Injury
NCT01209169 ·Status: COMPLETED
-
Early Screening and Diagnosis of CKD
NCT02841371 ·Status: RECRUITING