KV-PREDICT Diagnostic Device in Patients With Heart Failure
NCT07805213 · Status: NOT_YET_RECRUITING · Phase: NA · Type: INTERVENTIONAL · Enrollment: 120
Last updated 2026-09-04
Summary
This is a pilot, single-center, non-invasive interventional study evaluating the performance of KV-PREDICT, an investigational diagnostic medical device (Class IIa, not CE-marked), in adult patients with heart failure. During a single scheduled outpatient visit, the device is placed externally on the chest, over clothing, and records a single-lead ECG together with cardiac mechanical vibration signals for about 10 seconds. The study assesses whether the device can acquire signals of adequate quality and reproducibility to allow extraction of mechanical and electromechanical cardiac parameters (such as systolic and diastolic time intervals and the amplitudes of mechanical vibrations corresponding to the heart sounds S1-S4). The study does not aim to support clinical decisions, does not change patient management, and does not evaluate the diagnostic or predictive performance of the device. About 120 patients across NYHA functional classes I-III and different left-ventricular function profiles will be enrolled. No direct clinical benefit to participants is expected; anticipated risks are minimal given the non-invasive, brief procedure.
Conditions
Interventions
- DEVICE
-
KV-PREDICT
KV-PREDICT is applied externally to the chest, over clothing (no skin contact required), during a scheduled outpatient visit. It performs a single acquisition of about 10 seconds, simultaneously recording a single-lead ECG and cardiac mechanical vibration signals. The embedded software only acquires, filters, synchronizes and transmits the signals; it produces no automated clinical output or interpretation. During the same session, an external, standalone reference pulse oximeter (photoplethysmograph), which is not connected to and not part of the investigational device, is recorded separately and used only for offline comparison during signal analysis. All signals are analyzed offline for research purposes only.
Sponsors & Collaborators
-
KardioVis S.r.l.
lead INDUSTRY
Principal Investigators
-
Giuseppe Boriani, MD, PhD · Azienda Ospedaliero-Universitaria di Modena
Study Design
- Allocation
- NA
- Purpose
- DIAGNOSTIC
- Masking
- NONE
- Model
- SINGLE_GROUP
Eligibility
- Min Age
- 18 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2026-09-30
- Primary Completion
- 2027-04-30
- Completion
- 2027-04-30
Countries
- Italy
Study Locations
More Related Trials
-
Prospective Evaluation of the StatusFirst™ CHF NT-proBNP Device in Human Whole Blood and Plasma Samples
NCT00734045 ·Status: COMPLETED
-
Predictive Value of Vasodilator Challenge for Right Heart Failure After LVAD Implantation
NCT05836233 ·Status: UNKNOWN
-
A Two-way Communication System to Coach Elderly Patients With Heart Failure
NCT03294811 ·Status: COMPLETED ·Phase: NA
-
Remotely Monitoring Patients With Chronic Conditions in Their Home
NCT03207802 ·Status: COMPLETED
-
Remote Monitoring and Optimization of Heart Failure Therapy
NCT07622472 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
A Multi-site, Prospective, Non-interventional, Observational Data Collection Study in Patients Undergoing a Right Heart Catheterization
NCT07010562 ·Status: NOT_YET_RECRUITING
-
Evaluation of a New Non-Invasive Device for Detection of Endothelial Dysfunction
NCT00650741 ·Status: UNKNOWN
-
Artificial Intelligence and Smart Wearable Technologies for Early Detection of Acute Heart Failure
NCT05591443 ·Status: NOT_YET_RECRUITING
-
FIND HF Risk-guided Screening for Heart Failure - Pilot Study
NCT07367841 ·Status: NOT_YET_RECRUITING
-
Validity and Reliability of a Clinical Method for Assessment of Cardiorespiratory Fitness Using Seismocardiography
NCT05356871 ·Status: COMPLETED
-
Clinical Study on the Noninvasive Lung Fluid Monitoring System in Guiding the Treatment of Heart Failure
NCT06102031 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Exploratory Study of the Diagnostic Potential of an Innovative Thoracic Vibration Analysis Technique
NCT06661200 ·Status: COMPLETED ·Phase: NA
-
Evaluation of the Effectiveness of the Cardiostory Device in Distinguishing Heart Failure From Other Causes in Patients Presenting With Dyspnea.
NCT07685106 ·Status: RECRUITING
-
Early Detection and IntervenTion in Heart Failure
NCT07731490 ·Status: RECRUITING ·Phase: NA
-
Monitoring Oedema in Heart Failure to Improve Function and Reduce Hospitalisation Risk
NCT07067658 ·Status: RECRUITING ·Phase: NA
-
Comparison of Three-dimensional and Two-dimensional Left Ventricle Strain With Speckle-tracking Echocardiography in Heart Failure With Reduced and Mildly Reduced Ejection Fraction
NCT07741305 ·Status: RECRUITING
-
Utilising AI Analysis of Sounds To prEdict heaRt failurE decOmpensation
NCT06555757 ·Status: RECRUITING
-
Myovista vs NT Pro-BNP Heart Failure Referral Tool
NCT05068154 ·Status: UNKNOWN
-
Magnetocardiography (MCG) Device Use in Patients With Elevated Troponin
NCT06620744 ·Status: COMPLETED ·Phase: NA
-
Non-Invasive Detection of Right-to-Left Cardiac Shunts
NCT07420400 ·Status: RECRUITING
-
Vivio At-Home Study
NCT07730268 ·Status: ENROLLING_BY_INVITATION ·Phase: NA
-
US Benchmarking Clinical Study
NCT07215715 ·Status: RECRUITING
-
Acute Safety and Efficacy of the Pivot Bridge System for Functional Tricuspid Regurgitation
NCT07385625 ·Status: RECRUITING ·Phase: NA
-
Artificial Intelligence (AI) Analysis of Synchronized Phonocardiography (PCG) and Electrocardiogram(ECG)
NCT06009718 ·Status: RECRUITING
-
Assessmet of Patients With PAH Right Ventricular Volume
NCT01557582 ·Status: COMPLETED ·Phase: NA