Accuracy of Respiree Pulse Oximeters With Profound Hypoxia
NCT07785050 · Status: COMPLETED · Type: OBSERVATIONAL · Enrollment: 24
Last updated 2026-08-26
Summary
The aim of this project is to test the accuracy of pulse oximeters during mild, moderate and severe hypoxia. This is done by comparing the reading of the pulse oximeter during brief, steady state hypoxia with a gold-standard measurement of blood oxyhemoglobin saturation (arterial blood sample processed in a laboratory hemoximeter). The data obtained is submitted by pulse oximeter manufacturers to the FDA for device approval.
Conditions
- Healthy Volunteer
Interventions
- DEVICE
-
Respiree SpO2
The aim of this project is to test the accuracy of pulse oximeters during mild, moderate and severe hypoxia. This is done by comparing the reading of the pulse oximeter during brief, steady state hypoxia with a gold-standard measurement of blood oxyhemoglobin saturation (arterial blood sample processed in a laboratory hemoximeter). The data obtained is submitted by pulse oximeter manufacturers to the FDA for device approval
Sponsors & Collaborators
-
University of California, San Francisco
collaborator OTHER -
Respiree Pte Ltd
lead INDUSTRY
Eligibility
- Min Age
- 18 Years
- Max Age
- 49 Years
- Sex
- ALL
- Healthy Volunteers
- Yes
Timeline & Regulatory
- Start
- 2026-01-13
- Primary Completion
- 2026-01-22
- Completion
- 2026-06-18
Countries
- United States
Study Locations
More Related Trials
-
Induced Hypoxia Study for Validation of SpO2 Accuracy
NCT00788983 ·Status: COMPLETED
-
SpO2 Accuracy of Noninvasive Disposable Pulse Oximeter Sensor With Motion Conditions
NCT05264116 ·Status: COMPLETED ·Phase: NA
-
Accuracy of Pulse Oximeters in Profound Hypoxia
NCT05920278 ·Status: COMPLETED
-
Accuracy of SpO2 for Noninvasive Pulse Oximeter Sensor (LNCS ADTX)
NCT03125018 ·Status: COMPLETED ·Phase: NA
-
Accuracy of Pulse Oximeters With Profound Hypoxia
NCT04324385 ·Status: COMPLETED
-
Pulse Oximeter Responses to Multiple Levels of Stable Hypoxia
NCT01253785 ·Status: COMPLETED
-
Comparison of Pulse Oximetry (SpO2) With Different Oximeters and Arterial Saturation (SaO2): Oxygap2 Study
NCT06102499 ·Status: RECRUITING
-
Clinical Study of Peripheral Capillary Oxygen Saturation (SpO2): Vital Signs Patch (VSP)
NCT01899911 ·Status: COMPLETED ·Phase: NA
-
Pulse Oximeter Validation Study for the Perin Health Patch
NCT07027150 ·Status: COMPLETED
-
Accuracy of Evie Ring Pulse Oximeter in Profound Hypoxia
NCT06101654 ·Status: COMPLETED
-
Hypoxia and Hemodilution Testing in Healthy Adult Volunteers
NCT07503171 ·Status: NOT_YET_RECRUITING
-
Comparison of Oxygen Delivery Devices for Reversal of Altitude-Induced Hypoxemia in Normal Subjects
NCT01477450 ·Status: COMPLETED ·Phase: NA
-
Accuracy of Owlet Smart Sock Sensor 3rd Generation With Profound Hypoxia
NCT04446247 ·Status: COMPLETED
-
Accuracy of Oxygen Saturation (SpO2) Noninvasive Pulse Oximeter Sensor (RD Disposable) Under Motion Conditions
NCT03124784 ·Status: COMPLETED ·Phase: NA
-
Hypoxia Blood Validation in Multiple Pulse Oximeters
NCT00881829 ·Status: UNKNOWN
-
SpO2 Validation of Noninvasive Red Diamond Disposable Pulse Oximeter Sensor
NCT03124602 ·Status: COMPLETED ·Phase: NA
-
OxyGap : Comparison Between Different Pulse Oximeter and With the Arterial Blood Gase
NCT04772183 ·Status: RECRUITING
-
Accuracy of SpO2 for Noninvasive Pulse Oximeter Sensor (RD DCI)
NCT03124797 ·Status: COMPLETED ·Phase: NA
-
SpO2 Accuracy in Children
NCT07168798 ·Status: ENROLLING_BY_INVITATION
-
Calibration and Evaluation of an Audio Pulse Oximeter Sensor (AudioOx) at Ascent and Descent From Simulated Altitude
NCT01732029 ·Status: COMPLETED ·Phase: NA
-
SpO2 Comparison Between Commercial Smartwatch and Medical-grade Pulse Oximeter During Hypoxia
NCT05657288 ·Status: UNKNOWN ·Phase: NA
-
An Invasive Controlled Desaturation Study to Determine the Accuracy of the CART-I Pulse Oximeter
NCT05693961 ·Status: COMPLETED ·Phase: NA
-
Controlled Desaturation Study for TipTraQ SpO2 Performance Validation
NCT06634693 ·Status: COMPLETED
-
Oxitone Sp02 Hypoxia Test Versus Reference Pulse Oximetry
NCT02870179 ·Status: COMPLETED
-
Alternate Methodology of Pulse Oximeter Validation
NCT03628560 ·Status: TERMINATED ·Phase: NA