Comparison of Functional Outcome Between Locking Plate Technique Versus Hybrid Ilizarov Technique in Patients With Schatzker Type V and VI Tibial Plateau Fractures
NCT07773402 · Status: RECRUITING · Phase: NA · Type: INTERVENTIONAL · Enrollment: 78
Last updated 2026-08-19
Summary
This comparative clinical study will evaluate and compare the functional outcomes of patients with Schatzker type V and VI tibial plateau fractures treated using either the locking plate technique or the hybrid Ilizarov technique. Functional outcome will primarily be assessed using the Rasmussen Knee Functional Score. Fracture healing, time to union, non-union, delayed union, and infection will also be assessed and compared between the two treatment groups.
Conditions
- Tibial Plateau Fracture
Interventions
- PROCEDURE
-
Hybrid Ilizarov Fixation
Patients with Schatzker type V or VI tibial plateau fractures will undergo fracture reduction and fixation using a hybrid Ilizarov external fixation system under C-arm fluoroscopic guidance. Closed or minimally open reduction will be performed as appropriate. The construct will consist of a hybrid Ilizarov C-ring with appropriately tensioned Kirschner wires and Schanz screws. Additional wires or fixation components may be used when required to achieve adequate fracture stability and alignment. Bone graft or bone substitute may be used when clinically indicated.
- PROCEDURE
-
Locking Plate Fixation
Patients with Schatzker type V or VI tibial plateau fractures will undergo fracture reduction and internal fixation using a locking compression plate under C-arm fluoroscopic guidance. The appropriate surgical approach and medial and/or lateral plate configuration will be selected according to fracture morphology, comminution, and stability. Bone graft or bone substitute may be used when clinically indicated. Postoperative rehabilitation will include early knee range-of-motion exercises, non-weight-bearing ambulation initially, and progressive weight-bearing according to clinical and radiological fracture healing.
Sponsors & Collaborators
-
Prof. Sajjad Hussain Goraya
lead OTHER
Study Design
- Allocation
- RANDOMIZED
- Purpose
- TREATMENT
- Masking
- SINGLE
- Model
- PARALLEL
Eligibility
- Min Age
- 25 Years
- Max Age
- 50 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2026-08-16
- Primary Completion
- 2026-11-16
- Completion
- 2026-11-16
Countries
- Pakistan
Study Locations
More Related Trials
-
Morphological Characteristics of Inferior Pole Patellar Fractures and a Finite Element Analysis Combined with a Retrospective Clinical Study of Anchor Suture and Titanium Cable Cerclage Treatment
NCT06736639 ·Status: COMPLETED
-
Supra-Pectineal QLS Plating Vs Infra-pectineal Plating in Management of Quadrilateral Plate Fractures
NCT06440590 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Polyaxial Locking Plate Osteosynthesis in Proximal Tibia Fractures
NCT04680247 ·Status: COMPLETED ·Phase: NA
-
Proximal Femur Locking Compression Plates Versus Trochanteric Nails
NCT01128868 ·Status: COMPLETED ·Phase: NA
-
Lateral Decubitus vs Traction in the Supine Position in Proximal Femoral Nailing. Is There a Huge Difference?
NCT07410338 ·Status: COMPLETED ·Phase: NA
-
Surgical Management of Posterior Tibial Plateau Fractures
NCT03540719 ·Status: COMPLETED
-
Treatment of Tibial Plateau Fractures With Bone-graft and Bone Tamp Technique
NCT04807062 ·Status: COMPLETED ·Phase: NA
-
High-Strength Suture vs. Traditional Tension Band for Patellar Fractures
NCT07248982 ·Status: RECRUITING
-
Open Tibia Fractures a Comparative Study Between Biplane External Fixator and Locked Intramedullary Nail
NCT02064595 ·Status: COMPLETED ·Phase: NA
-
Minimally Invasive Locking Plate Fixation vs Reamed Intramedullary Nail Fixation on Patients With Open Tibia Fracture
NCT04072094 ·Status: UNKNOWN ·Phase: NA
-
Volar Locking Plate Comparison With External Fixator
NCT07576075 ·Status: RECRUITING ·Phase: NA
-
Is Far Cortical Locking More Effective Than Bicortical Locking in Treating AO 43A1-3 Fractures?
NCT06005090 ·Status: COMPLETED
-
Helical Blade vs Lag Screw Fixation for Cephalomedullary Nailing of Low Energy Intertrochanteric Hip Fractures
NCT04306198 ·Status: UNKNOWN ·Phase: NA
-
Hook Plate vs Tightrope in Fixation of Fracture Distal Third Clavicle
NCT03773848 ·Status: UNKNOWN ·Phase: NA
-
Is the Expert Nail With Poller Screws Superior to the Distal Tibial Locked Plate in the Management of Short Oblique Distal Tibial Fractures?
NCT06436365 ·Status: COMPLETED ·Phase: NA
-
Two-stage ORIF Vs Ex. Fix. in Complex Pilon Fractures
NCT05141227 ·Status: COMPLETED ·Phase: NA
-
3D Geplante Osteosynthesen Mit Patientenspezifischen Zielvorrichtungen
NCT02826538 ·Status: TERMINATED ·Phase: NA
-
Miniplate Versus k Wires in Management of Metacarpal Fracture
NCT04605341 ·Status: UNKNOWN ·Phase: NA
-
Fixation of Shaft Femure Fracrture by Ender Versus Plate
NCT07067333 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Comparative Evaluation of Minimally Invasive "tibial Tuberoplasty" Surgical Technique Versus Conventional Open Surgery for Tibial Plateau Fractures
NCT03444779 ·Status: COMPLETED ·Phase: NA
-
Primary Dynamization Versus Standard Interlocking Intramedullary Nail in Treatment of Tibial Shaft Fractures in Adults
NCT06147219 ·Status: RECRUITING ·Phase: NA
-
Treatment of Compound Tibia Fracture With a Microvascular Latissimus Dorsi Flap and the Ilizarov Technique
NCT02369991 ·Status: COMPLETED
-
Lateral Versus Anterior Spanning External Fixator for Tibial Plateau Fractures
NCT00610701 ·Status: TERMINATED ·Phase: NA
-
External Fixation Vs. Volar Plate for Distal Radius Fractures: Functional Outcomes
NCT06738693 ·Status: COMPLETED ·Phase: NA
-
Comparison of Interlock Nailing Versus Dynamic Compression Plating in Transverse Fractures of Tibia
NCT04958564 ·Status: COMPLETED ·Phase: NA