Access to Hygiene in Patients With Dental Implants Using Two Toothbrushes
NCT07724054 · Status: COMPLETED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 16
Last updated 2026-07-23
Summary
Peri-implant mucositis is a reversible inflammatory condition primarily caused by biofilm accumulation around dental implants. Effective plaque control is essential for disease resolution; however, the influence of toothbrush bristle design on plaque removal around implant-supported prostheses remains unclear. Polybutylene terephthalate (PBT) tapered-end bristles are more flexible than conventional medium-textured bristles and may improve access to peri-implant areas while increasing patient comfort. This study aims to compare the effectiveness of a PBT tapered-end toothbrush and a medium-textured toothbrush in plaque removal, peri-implant bacterial load reduction, and patient-reported outcomes in individuals with peri-implant mucositis. Each participant will use both toothbrushes in a randomized sequence separated by a six-week washout period. Visible plaque will be disclosed and quantified using standardized photographic analysis based on the Rustogi Modified Navy Plaque Index. Absolute and relative peri-implant bacterial loads of Porphyromonas gingivalis and Fusobacterium nucleatum, together with total bacterial load, will be quantified by quantitative polymerase chain reaction. Patient satisfaction, including perceived discomfort, comfort, ease of handling and intention to use, will be assessed using visual analogue scales.
Conditions
- Plaque Removal
- Peri Implant Mucositis
Interventions
- OTHER
-
Plaque removal
Plaque removal with a Polybutylene terephthalate (PBT) tapered-end toothbrush
Sponsors & Collaborators
-
Octavi Camps-Font
lead OTHER
Study Design
- Allocation
- RANDOMIZED
- Purpose
- SUPPORTIVE_CARE
- Masking
- SINGLE
- Model
- CROSSOVER
Eligibility
- Min Age
- 18 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2024-05-18
- Primary Completion
- 2026-05-20
- Completion
- 2026-06-10
Countries
- Spain
Study Locations
More Related Trials
-
The Adjunctive Effect of a Titanium Brush in the Non-Surgical Treatment of Peri-Implantitis
NCT06843928 ·Status: RECRUITING ·Phase: NA
-
Assessment of the Impact of Probiotics on Biofilm Formation on Removable Acrylic Dentures
NCT02736994 ·Status: COMPLETED ·Phase: NA
-
Impact of Oral Hygiene Instructions in the Resolution of Peri-implant Mucositis
NCT06535958 ·Status: COMPLETED ·Phase: NA
-
Comparing Cleaning Tools for Full-Arch Implant-Supported Fixed Prostheses
NCT07474493 ·Status: RECRUITING ·Phase: NA
-
The Effect of Different Shapes of Interdental Brushes in the Management of Peri-implant Mucositis and Gingivitis
NCT03575858 ·Status: WITHDRAWN ·Phase: NA
-
Randomized Clinical Trial to Evaluate the Predictability of 5.5 mm Dental Implants
NCT04929743 ·Status: COMPLETED ·Phase: NA
-
Maintenance Protocol for Implant Supported Hybrid Prosthesis.
NCT05482490 ·Status: UNKNOWN ·Phase: NA
-
Distance Between Dental Implants as a Risk Indicator for Peri-implant Disease.
NCT06364982 ·Status: RECRUITING
-
Microbiological Evaluation of the Effectiveness of Different Surface Decontamination Protocols for Dental Implants
NCT07529444 ·Status: RECRUITING ·Phase: NA
-
Efficacy of Non-surgical and Surgical Surface Decontamination Methods on Peri-implantitis-affected Implants
NCT06430268 ·Status: ENROLLING_BY_INVITATION ·Phase: NA
-
The Effect of Platform Switching on Single Implants in the Esthetic Zone, Following Flapless Surgery and Early-Loading Protocols
NCT02173236 ·Status: COMPLETED ·Phase: NA
-
Influence of the Implant-prosthetic Connection in the Marginal Bone Loss and Bacterial Leakage
NCT04328051 ·Status: UNKNOWN ·Phase: NA
-
Use of Glycine Powder and an Angled Implant Brush in Oral Hygiene Procedures in Patients Rehabilitated With Columbus Bridge Protocol
NCT07212855 ·Status: COMPLETED ·Phase: NA
-
In-patient Comparison of Immediately Loaded and Non-loaded Submerged and Transgingival Healed Implants Within 4 Months
NCT06408506 ·Status: COMPLETED ·Phase: NA
-
Effect of Probe Material on Peri-implant Probing
NCT07304752 ·Status: RECRUITING ·Phase: NA
-
0.2% Chx Gel vs Implant Bacterial Contamination
NCT03431766 ·Status: UNKNOWN ·Phase: NA
-
Accuracy of Metal Sleeve-Free Fully Guided Implant Surgery
NCT07364006 ·Status: RECRUITING ·Phase: NA
-
Influence of Implant Surface Decontamination on the Reconstructive Outcomes of Peri-implantitis
NCT05615051 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Preventive Maintenance Therapy on Peri-implant Diseases
NCT02789306 ·Status: COMPLETED
-
Evaluation of Using Different Screwed Abutment Height
NCT06017115 ·Status: COMPLETED ·Phase: NA
-
Efficacy of Implant Surface Characteristics in Patients With History of Periodontitis
NCT05010382 ·Status: COMPLETED ·Phase: NA
-
Multicentre Study on the Impact of Transmucosal Abutment Surface Characteristics on Peri-implant Tissues.
NCT07246499 ·Status: COMPLETED ·Phase: NA
-
Long-term Surgical Therapeutic Outcomes of Peri-Implantitis
NCT03772652 ·Status: TERMINATED
-
Effect of a Maintenance Protocol After Surgical Treatment of Peri-implantitis
NCT05574218 ·Status: COMPLETED ·Phase: NA
-
Mechanical Treatment Peri-Implant Mucositis
NCT05664425 ·Status: COMPLETED ·Phase: NA