Evaluate the Effectiveness and Safety of At-Home Rehabilitation Gait Training Using a Hip-assisted Wearable Robot in Stroke Patients
NCT07716475 · Status: RECRUITING · Phase: NA · Type: INTERVENTIONAL · Enrollment: 8
Last updated 2026-07-21
Summary
The goal of this clinical trial is to learn whether a wearable monitoring system can help adults who have had a stroke get more out of a home exercise program. The system tracks how participants walk and move, then gives them feedback. Researchers want to know if this feedback improves walking, thinking and memory, and daily activity.
The wearable monitoring system has three parts:
A shoe insole sensor that measures how a person walks A wrist band that tracks daily activity, like a fitness watch A mobile app that gives feedback and lets participants report how they feel
The main questions this study aims to answer are:
Does feedback from the wearable system improve physical function, thinking and memory, and daily activity during a home exercise program? How satisfied are participants with using the wearable system?
Researchers will compare two groups. Both groups do the same home exercise program for 6 weeks. One group uses the wearable system and gets feedback. The other group does the program without the wearable system or feedback. This comparison shows whether the feedback itself makes a difference.
Who can take part: adults who have had a stroke and \[key eligibility in plain words, e.g., "can walk a short distance with or without help"\]. The study plans to enroll about \[number\] participants.
Participants in the wearable group will:
Get an insole sensor, a wrist activity tracker, and access to a mobile app Learn a home exercise program from the study team Wear the insole sensor and activity tracker while exercising at home for 6 weeks Use the app to see their feedback and report daily health information Complete a survey about their experience at the end
Participants in the comparison group will:
Do the same home exercise program for 6 weeks, without the wearable system or feedback.
Conditions
Interventions
- DEVICE
-
hip-assisted wearable robot
A hip-assisted wearable robot (wearable gait-assist robot) that assists flexion and extension of the hip joint during walking. The battery-powered device is controlled through a paired mobile application via Bluetooth, and its assistive force can be adjusted to each participant. A visiting physical or occupational therapist applies the device and delivers gait training at the participant's home for 4 sessions over 2 weeks, 30 minutes per session, under a physician's prescription and supervision.
Sponsors & Collaborators
-
Korea Health Industry Development Institute
collaborator OTHER_GOV -
Yonsei University
lead OTHER
Principal Investigators
-
Na Young Kim, MD, PhD · Severance Hospital
Study Design
- Allocation
- NA
- Purpose
- HEALTH_SERVICES_RESEARCH
- Masking
- NONE
- Model
- SINGLE_GROUP
Eligibility
- Min Age
- 19 Years
- Max Age
- 80 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2026-07-06
- Primary Completion
- 2026-09-30
- Completion
- 2027-07-30
Countries
- South Korea
Study Locations
More Related Trials
-
The Feasibility and Therapeutic Effect of Hybrid End-effector Robot-assisted Gait Training With an Active-assisted Module in Chronic Stroke Survivors
NCT07034521 ·Status: RECRUITING ·Phase: NA
-
Robot-assisted Training for Stroke Recovery
NCT02053233 ·Status: COMPLETED ·Phase: NA
-
Cortical Activity and Gait Function for Robotic Gait Training in Hemiparetic Stroke
NCT04054739 ·Status: COMPLETED ·Phase: NA
-
Walking Therapy In Hemiparetic Stroke Patients Using Robotic-Assisted Treadmill Training
NCT00075283 ·Status: UNKNOWN ·Phase: PHASE1
-
Virtual Reality-Integrated Propulsion Feedback for Stroke Rehab
NCT07087743 ·Status: RECRUITING ·Phase: NA
-
Robot Assisted Gait Training in Patients With Infratentorial Stroke
NCT02680691 ·Status: COMPLETED ·Phase: NA
-
To Investigate the Effects of Robotic-assisted Gait Training in Stroke Patients
NCT04033185 ·Status: COMPLETED ·Phase: NA
-
Research on Clinical Safety and Effectiveness of Wearable Assistive Devices With Flexible Structure for Daily Life Support of Stroke Patients
NCT06549127 ·Status: COMPLETED ·Phase: NA
-
The Effect of Robot-assisted Gait Training in Individuals With Chronic Stroke
NCT06746415 ·Status: RECRUITING ·Phase: NA
-
Feasibility and Safety of In-bed Self-exercise in Patients With Subacute Stroke
NCT05820815 ·Status: RECRUITING ·Phase: NA
-
Ankle Robotics After Stroke
NCT04594837 ·Status: UNKNOWN ·Phase: NA
-
Effects of Rehabilitation Robots-Morning Walk in Individuals With Hemiparesis
NCT06374706 ·Status: COMPLETED ·Phase: NA
-
Safety and Efficacy of Early Brain-Computer Interface Training After Reperfusion Therapy in Acute Ischemic Stroke
NCT07585058 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Walking and tSCS in Non-ambulatory Stroke Survivors
NCT07226518 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Resume Walking by an Interactive Mobile Robot of Rehabilitation After Vascular Stroke (Cerebral Vascular Stroke) in Combination With Traditional Reeducation
NCT03686280 ·Status: COMPLETED ·Phase: NA
-
A Novel Wrist Wearable Sensor System to Promote Hemiparetic Upper Extremity Use in Subacute Stroke Survivors
NCT06797154 ·Status: RECRUITING ·Phase: NA
-
Effects of Intensive Robot-assisted Therapy in Patients With Subacute Stroke
NCT01767480 ·Status: COMPLETED ·Phase: NA
-
Investigating the Mechanisms of Welwalk Robot in Restoring Motor Function of the Lower Extremities in Stroke Patients
NCT07057700 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Robotic Versus Conventional Training on Hemiplegic Gait.
NCT01187277 ·Status: COMPLETED ·Phase: PHASE3
-
Clinical Efficacy of Exoskeleton Assistance for Individuals Post-Stroke
NCT06064604 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Energy Consumption and Cardiorespiratory Load During Robot-Assisted Gait Training in Non-Ambulatory Stroke Patients
NCT02995616 ·Status: COMPLETED ·Phase: NA
-
Therapeutic Effects of a New Upper Limb Robot Assisted Therapy Device for Persons After Stroke
NCT01723046 ·Status: UNKNOWN ·Phase: NA
-
Robot-Assisted Training Versus Standard Training in Ischemic Stroke
NCT06273475 ·Status: RECRUITING ·Phase: NA
-
Home Exercise With Wearable Sensors
NCT03416842 ·Status: COMPLETED ·Phase: PHASE1
-
Safety and Efficacy of Samsung GEMS-H Device Training in Sub-Acute and Chronic Stroke
NCT04285060 ·Status: UNKNOWN ·Phase: NA