Study on Influencing Factors and Intervention of Silent Aspiration After Heart Valve Operation in Elderly Patients
NCT07710001 · Status: TERMINATED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 117
Last updated 2026-07-17
Summary
Objective To investigate the safety and effectiveness of interference electrical stimulation in the prevention of silent aspiration after heart valve surgery in elderly patients. Silent aspiration was diagnosed when either pepsin level \>200 ng/ml or α-amylase level \>1685 U/L was detected in airway secretions.
Conditions
- Elderly Heart Valve Surgery
- Silent Aspiration
Interventions
- DEVICE
-
The intervention was delivered using the Gentle Stim Electrical Stimulation Therapy Device (Model: JC-2071)
Prior to the intervention, the patient's skin was inspected for symptoms such as redness, swelling, or ulceration, and cleansed with an alcohol swab. The leads of the Gentle Stim electrical stimulation therapy device were checked to ensure they were safe and unobstructed. After resetting all settings to zero, the device was switched on. Electrode pads were attached, with two pairs of electrodes placed on the upper and lower lateral aspects of the thyroid cartilage, spaced 4 cm apart, and properly secured. The stimulation intensity was adjusted: one pair of electrodes was set to an output of 2050 Hz, and the other pair to 2000 Hz. The current was set between 2 and 2.5 mA.
- OTHER
-
Usual Care Group
A sham intervention was performed using the Gentle Stim electrical stimulation therapy device. The device was applied identically to the experimental group but without delivering any electrical current. The wearing duration was consistent with that of the experimental group.
Sponsors & Collaborators
-
Fujian Medical University Union Hospital
lead OTHER
Study Design
- Allocation
- RANDOMIZED
- Purpose
- SUPPORTIVE_CARE
- Masking
- SINGLE
- Model
- PARALLEL
Eligibility
- Min Age
- 60 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2025-02-01
- Primary Completion
- 2026-01-31
- Completion
- 2026-01-31
Countries
- China
Study Locations
More Related Trials
-
Interest of Pulse Wave Velocity Measurement as a Predictor of Severity of Aortic Stenosis
NCT03140735 ·Status: WITHDRAWN ·Phase: NA
-
Bioabsorbable Occluder for Outlet VSD: Safety and Aortic Valve Effects
NCT07040579 ·Status: NOT_YET_RECRUITING
-
Cardiac Amyloidosis in Patients With Aortic Stenosis
NCT07170306 ·Status: NOT_YET_RECRUITING
-
PRECISE-AFMR I: Transcatheter Mitral Valve Edge-to-Edge Repair for Atrial Functional Mitral Regurgitation in Patients at High Surgical Risk
NCT07741253 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Multicenter Registry Study of Aortic Valve Stenosis in Zhejiang Elderly(Mrs AVS)
NCT03797820 ·Status: UNKNOWN
-
Transcatheter Self-expandable Valve Implantation for the Treatment of Severe Native Aortic Regurgitation
NCT04864145 ·Status: RECRUITING ·Phase: NA
-
Transcatheter Aortic Valve Implantation: Comparison of the Effects of Ultrasound-Guided Pericapsular Nerve Group Block and Fascia Iliaca Block on Postoperative Analgesia Management
NCT06773780 ·Status: RECRUITING ·Phase: NA
-
3-Dimensional Simulation Guided Transcatheter Aortic Valve Replacement in Aortic Regurgitation(DIGITAL)
NCT07398911 ·Status: ENROLLING_BY_INVITATION ·Phase: NA
-
A Prospective, Multicenter, Observational Study Evaluating Safety and Effectiveness of SAPIEN 3 Transcatheter Aortic Valve Replacement for Type-0 Bicuspid Aortic Valve Stenosis Patients in China
NCT07450196 ·Status: NOT_YET_RECRUITING
-
Echo-Guided vs Fluoroscopy-Guided Transcatheter Aortic Valve Replacement in Patients With Aortic Stenosis(ECHO-TAVR)
NCT07317804 ·Status: NOT_YET_RECRUITING ·Phase: PHASE4
-
A Prospective, Multicenter, Randomized Controlled Clinical Trial of Transcatheter Tricuspid Valve Clipping Systems.
NCT07433504 ·Status: RECRUITING ·Phase: NA
-
Study on Heart Block Risks Using Outcome-Based Modeling
NCT07065123 ·Status: COMPLETED
-
Cardiac Contractility Modulation Therapy in Amyloid Cardiomyopathy Patients With Heart Failure
NCT05167799 ·Status: UNKNOWN
-
Active Post-Market Surveillance of Innovative Devices for Valvular Heart Disease
NCT07605624 ·Status: NOT_YET_RECRUITING
-
The Impact of Atrial Pressure Change Before and After Combined Procedure
NCT05106270 ·Status: RECRUITING
-
Safety and Efficacy Continued Access Study of the Medtronic CoreValve® System in the Treatment of Symptomatic Severe Aortic Stenosis in Very High Risk Subjects and High Risk Subjects Who Need Aortic Valve Replacement
NCT01531374 ·Status: COMPLETED ·Phase: NA
-
Aortic Stenosis Evaluated Via Modern Ballistocardiography and Seismocardiography
NCT04231201 ·Status: SUSPENDED
-
Sapien 3 Transcatheter Aortic Valve Replacement in Young Aortic Valve Stenosis Patients From China
NCT06830499 ·Status: RECRUITING
-
A Prospective, Randomized, Blind, Controlled Multicenter Clinical Study Comparing the Effectiveness of Preventive Ventricular Arrhythmia Ablation on the Prognosis After Left Ventricular Assist Device (LVAD) Surgery.
NCT07589738 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Effectiveness and Safety of a Type A Dissection Total Endovascular Reconstruction System in Promoting Favorable Distal Aortic Remodeling
NCT07402252 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Early Outcomes of Concomitant Transcatheter Aortic Valve Implantation and Off-pump Coronary Artery Bypass Grafting in Management of Severe Symptomatic Aortic Stenosis and Coronary Artery Disease
NCT04525339 ·Status: UNKNOWN
-
Clinical Outcome of Patients With Low-gradient Severe Aortic Stenosis
NCT02010177 ·Status: SUSPENDED
-
Prizvalve Transcatheter Aortic Valve in Failing Bioprosthetic Valves
NCT07122050 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Evaluate the Transcatheter Artificial Aortic Valve and Transcatheter Artificial Heart Values Delivery System
NCT03788590 ·Status: UNKNOWN ·Phase: NA
-
Clinical Trial of Electro-Acupuncture Preconditioning in Patients Underwent Heart Valve Replacement Surgery
NCT00732459 ·Status: UNKNOWN