Study on Heart Block Risks Using Outcome-Based Modeling
NCT07065123 · Status: COMPLETED · Type: OBSERVATIONAL · Enrollment: 112
Last updated 2025-07-15
Summary
This study developed a prediction model for high-grade atrioventricular block (AVB) and complete left bundle branch block (CLBBB) following transcatheter aortic valve replacement (TAVR) in Chinese patients with aortic stenosis (AS). Analyzing 112 patients from Sun Yat-sen Memorial Hospital (2017-2024), the study incorporated clinical, electrocardiographic, and procedural variables to identify risk factors via logistic regression. A nomogram was constructed and validated internally (bootstrapping) and externally (temporal validation), with performance assessed using AUC, C-index, and calibration tests. The model aims to improve preoperative risk stratification and guide individualized management for TAVR-related conduction disturbances in this understudied population. Analyses were conducted in R 4.2.3 (significance: \*p\* \< 0.05).
Conditions
- Left Bundle-Branch Block
- Aortic Stenosis
Interventions
- OTHER
-
The population undergoing TAVR for aortic valve stenosis with outcomes of permanent pacemaker implantation and complete left bundle branch block after surgery
The population undergoing TAVR for aortic valve stenosis with outcomes of permanent pacemaker implantation and complete left bundle branch block after surgery
Sponsors & Collaborators
-
Sun Yat-Sen Memorial Hospital of Sun Yat-Sen University
lead OTHER
Eligibility
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2017-01-01
- Primary Completion
- 2025-01-01
- Completion
- 2025-06-26
More Related Trials
-
To Evaluate Safety and Effectiveness of Transcatheter Aortic Valve System in Patients With Severe Aortic Insufficiency
NCT05424653 ·Status: UNKNOWN ·Phase: NA
-
TAVR for Aortic Valve Disease
NCT05439863 ·Status: RECRUITING
-
A Clinical Study on the Use of the Sentinel Cerebral Protection Device During TAVR for the Prevention of Procedure-Related Stroke
NCT07045233 ·Status: ENROLLING_BY_INVITATION
-
Safety and Efficacy of Post-marketing Transcatheter Aortic Valves in "Real World" Chinese Patients
NCT06257043 ·Status: RECRUITING
-
Safety and Efficacy of Emergent TAVI in Patients With Severe AS
NCT05528211 ·Status: NOT_YET_RECRUITING
-
Prizvalve Transcatheter Aortic Valve in Failing Bioprosthetic Valves
NCT07122050 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Outcome Prediction in Patients With Aortic Stenosis After TAVI
NCT06043180 ·Status: NOT_YET_RECRUITING
-
Evaluation of ARi With OpSens SavvyWire
NCT06295068 ·Status: TERMINATED
-
ASAN Medical Center Aortic Valve Replacement Registry
NCT03298178 ·Status: ACTIVE_NOT_RECRUITING
-
Study on Optimal Treatment Strategy for Elderly Patients With High-risk Complex Aortic Valve Disease
NCT05044377 ·Status: UNKNOWN
-
TAVIS Registry - Trilogy Heart Valve System for Management of Patients With Aortic Valve Disease
NCT05536310 ·Status: NOT_YET_RECRUITING
-
Surgical vs Transcatheter Aortic Valve Replacement in YOUNG Patients
NCT06861361 ·Status: RECRUITING ·Phase: NA
-
Safety and Efficacy Continued Access Study of the Medtronic CoreValve® System in the Treatment of Symptomatic Severe Aortic Stenosis in Very High Risk Subjects and High Risk Subjects Who Need Aortic Valve Replacement
NCT01531374 ·Status: COMPLETED ·Phase: NA
-
Alternative Access Approaches for Transcatheter Aortic Valve Replace (TAVR) in Inoperable Patients With Aortic Stenosis
NCT01787084 ·Status: COMPLETED
-
Cardiac Amyloidosis in Patients With Aortic Stenosis
NCT07170306 ·Status: NOT_YET_RECRUITING
-
TAVR vs. SAVR Study of VitaFlow Liberty® for Severe BAV Stenosis
NCT06597188 ·Status: ENROLLING_BY_INVITATION ·Phase: NA
-
Randomized Trial of TAVI vs. SAVR in Patients With Severe Aortic Valve Stenosis at Low to Intermediate Risk of Mortality
NCT03112980 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
TRANscatheter or SurgIcal Aortic Valve ReplacemenT in All-Comers With Severe Aortic Valve Stenosis
NCT02838199 ·Status: WITHDRAWN ·Phase: PHASE4
-
Comparison of Sutureless Vs. Standard Biological Prostheses for Surgical Aortic Valve Replacement
NCT03965065 ·Status: UNKNOWN ·Phase: NA
-
Medtronic Evolut Transcatheter Aortic Valve Replacement in Low Risk Patients
NCT02701283 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Multicenter Study Evaluating the Efficacy of an Intervention Aimed At Reducing the Length of Stay After Transfemoral Transcatheter Aortic Valve Implantation
NCT04503655 ·Status: COMPLETED ·Phase: NA
-
Structured Shared Decision Making for Patients Undergoing SAVR or TAVR
NCT05711186 ·Status: RECRUITING ·Phase: NA
-
Transaxillary TAVR With Solely Echocardiography Guidance
NCT07035847 ·Status: RECRUITING ·Phase: NA
-
EARLY TAVR: Evaluation of TAVR Compared to Surveillance for Patients With Asymptomatic Severe Aortic Stenosis
NCT03042104 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Comparative Analysis of Stented Biological Prosthesis Versus Aortic Allograft in Patients With Degenerative Aortic Valve Disease
NCT07210541 ·Status: COMPLETED